# K090037: Medicalgorithmics Real-Time Ecg Monitor and Arrhythmia Detector, Model Pocketecg

- Pathway: 510(k) (Abbreviated)
- Applicant: Medicalgorithmics SP Z.O.O.
- Decided: May 22, 2009 after 136 days
- Product code: DSI (Detector And Alarm, Arrhythmia)
- Device class: 2
- Regulation: 21 CFR 870.1025
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 5 generations back to K882803 (1988). 19 ancestors in all.
7 later devices descend from it; 1 cites it directly.
0 of 27 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K072558: Cardionet Ambulatory Ecg Monitor with Arrhythmia Detection, Model CN1005, Cardionet, Inc. (2007) Summary page 1.
- K071995: CG-6108 Continuous Ecg Monitor and Arrhythmia Detector, Card Guard Scientific Survival, Ltd. (2007) Summary page 1.

## Most influential descendants
- K100155: Truvue Wireless Ambulatory Ecg Monitoring System (2010), 6 descendants of its own
- K160064: MoMe Kardia Wireless Ambulatory ECG Monitoring and Detection System (2016), 3 descendants of its own
- K230265: MoMe® ARC Wireless Ambulatory ECG Monitoring and Detection System (2023), 1 descendant of its own
- K250356: MoMe ARC® Wireless Ambulatory ECG Monitoring and Detection System (32000) (2025), 0 descendants of its own
- K231276: SmartCardia 7L Platform (2023), 0 descendants of its own

## Indications for use
The indications for use for the PocketECG monitor are as follows: 1. Patients who have a demonstrated need for cardiac monitoring. These may include but are not limited to patients who require monitoring for: a) non-life threatening arrhythmias such as supraventricular tachycardias (e.g. atrial fibrillation, atrial flutter, PACs, PSVT) and ventricular ectopy; b) evaluation of bradyarrhytthias and intermittent bundle branch block, including after cardiovascular surgery and myocardial infarction; and c) arrhythmias associated with co-morbid conditions such as hyperthyroidism or chronic lung disease 2. Patients with symptoms that may be due to cardiac arrhythmias. These may include but are not limited to symptoms such as: a) dizziness or lightheadedness; b) syncope of unknown etiology in which arrhythmias are suspected or need to be excluded; and c) dyspnea (shortness of breath) 3. Patients with palpitations with or without known arrhythmias to obtain correlation of rhythm with symptoms. 4. Patients who require monitoring of effect of drugs to control ventricular rate in various atrial arrhythmias (e.g. atrial fibrillation) 5. Patients recovering from cardiac surgery who are indicated for outpatient arrhythmia monitoring 6. Patients with diagnosed sleep disordered breathing including sleep apnea (obstructive, central) to evaluate possible nocturnal arrliythmias 7. Patients requiring arrhythmia evaluation of etiology of stroke or transient cerebral ischemia, possibly secondary to atrial fibrillation or atria] flutter. 8. Data from the device may be used by another device to analyze, measure or report QT interval. The device is not intended to sound any alarms for QT interval changes.

Source page: https://510kreport.com/device/K090037