Stanbio Laboratory Hemopoint H2 DM Hemoglobin Measurement System

K090093510(k) SpecialCleared Jun 10, 2009147-day reviewClass II21 CFR 864.5620

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Stanbio Laboratory · GKR System, Hemoglobin, Automated

Cleared on Jun 10, 2009 after a 147-day review. The FDA summary names its predicate without a number.

Decided
Jun 10, 2009
Review
147 days
Class
Class II
Product code
GKR
Recalls
None
Predicates
0

The FDA summary names its predicate without a number.

FIG. 1 — Lineage of K090093Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GKR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GKR device

  1. #1 K201217 HemoCue Hb 301 Systemscore 0.4 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—HemoPoint® H2 Hemoglobin Measurement System with microcuvette
Named without a submission number
—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All GKR devices

GKR System, Hemoglobin, Automated: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · GKR

2in 2020

2008: 12009: 12011: 12013: 22017: 12018: 22019: 12020: 2
2007high 2 (2013) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GKR

Too few GKR 510(k)s in any year since 2007 to give a median.

Recalls per year · GKR

1in 2013

2010: 12011: 12013: 1
2007high 1 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GKR

1in 2024

2008: 22009: 162010: 92011: 122012: 252013: 432014: 312015: 192016: 92019: 92020: 12021: 12022: 12024: 1
2007high 43 (2013) · low 0 (2007)2025

MAUDE reports naming product code GKR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20081—02
20091—016
20100—19
20111—112
20120—025
20132—143
20140—031
20150—019
20160—09
20171—00
20182—00
20191—09
20202—01
20210—01
20220—01
20230—00
20240—01
20250—00
20260—0—

What is it indicated for?

The HemoPoint ® H2 Hemoglobin Measurement System is indicated for the quantitative determination of hemoglobin in arterial, venous, or capillary blood. The HemoPoint H2 Microcuvettes are indicated for use in the HemoPoint® H2 DM Hemoglobin Measurement System. The microcuvettes are intended to be used only once and must be disposed of after use as potentially infectious waste. Estimation of hematocrit as a function of Hemoglobin is performed for normal…

Read the full statement (116 words)

The HemoPoint ® H2 Hemoglobin Measurement System is indicated for the quantitative determination of hemoglobin in arterial, venous, or capillary blood.

The HemoPoint H2 Microcuvettes are indicated for use in the HemoPoint® H2 DM Hemoglobin Measurement System. The microcuvettes are intended to be used only once and must be disposed of after use as potentially infectious waste.

Estimation of hematocrit as a function of Hemoglobin is performed for normal hemoglobin ranges only (120 to 180 g/liter or 12.0 to 18.0 g/deciliter). The estimated hematocrit is not indicative of disease states such as anemia and abnormal values will not be reported.

The DM (Data Management) system allows enhanced data management features.

For In Vitro Diagnostic Use Only

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K090093: Stanbio Laboratory Hemopoint H2 DM Hemoglobin Measurement System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K090093

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026