510(k) Report

510(k) · Cleared

Recalled · Class I · 2026

Proguide Chronic Dialysis Catheter

K090148510(k) TraditionalCleared Apr 13, 200982-day reviewClass II21 CFR 876.5540Recalls 1 (1 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Merit Medical Systems, Inc. · MSD Catheter, Hemodialysis, Implanted

Cleared on Apr 13, 2009 as substantially equivalent to K042016 (Datascope Corp., 2004) and 1 other predicate after an 82-day review. Its family tree reaches back 3 generations to 1998. 1 of the 5 devices in its family, counting itself, has a Class I recall. It has been recalled once, including a Class I recall.

Decided
Apr 13, 2009
Review
82 days
Class
Class II
Product code
MSD
Recalls
1 (1 Class I)
Predicates
2

Its longest line of descent runs back 3 generations to K972207 (1998). 4 ancestors in all. No later device cites it as a predicate yet. 1 of the 5 devices in this family, counting this one, has a Class I recall.

  1. Root · 3 generations backK972207 Medcomp Ash Split-Cath 28CM, Medcomp Ash Split-Cath 32CMMedcomp · 1998
  2. 2 generations backK994105 Hemo-Flow Double Lumen Catheter, Models HFS-24, HFS-28, HFS-32…Medical Components, Inc. · 2001 · Recalled
  3. 1 generation backK042016 Datascope Proguide Chronic Dialysis CatheterDatascope Corp. · 2004
  4. This deviceK090148 Proguide Chronic Dialysis CatheterMerit Medical Systems, Inc. · 2009
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K972207Medcomp Ash Split-Cath 28CM, Medcomp Ash Split-Cath 32CMMedcomp1998—
−2K994105Hemo-Flow Double Lumen Catheter, Models HFS-24, HFS-28, HFS-32, HFS-36, HFS-40Medical Components, Inc.20012
−1K042016Datascope Proguide Chronic Dialysis CatheterDatascope Corp.2004—
0 (this device)K090148Proguide Chronic Dialysis CatheterMerit Medical Systems, Inc.2009—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200410
FIG. 1 — Lineage of K090148, 1998–2009Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MSD device

  1. #1 K241581 Hemodialysis Catheterscore 12.3 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K042016Datascope Proguide Chronic Dialysis Catheter
Summary page 1
…Name: ProGuide Chronic Dialysis Catheter Classification Name: Implanted Hemodialysis Catheter Premarket Notification:K042016 Manufacturer: Merit Medical Systems, Inc. Predicate Devices Trade Name:…
Datascope Corp.2004—
*K040402Angiodynamics, Inc. More-Flow Hemodialysis Catheter and Procedure Kit
Summary page 1
…EvenMore® Chronic Hemodialysis Catheter Classification Name: Implanted Hemodialysis Catheter Premarket Notification:K040402 Manufacturer: AngioDynamics® Inc. Class III Classification 21 CFR § 87…
AngioDynamics, Inc.2004—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Feb 13, 2026Class IZ-1576-2026Process control16F dual-valved splittable sheath introducer due to a design defect, may not split as intended, which may result in hemorrhage, foreign bodies, procedure delay, embolization/thrombosis, impaired catheter function, loss of vessel for…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 4 companies; a new generation was cleared every 3.6 years on median.
  • 1 of the 4 ancestors has a recall of any class.

How does its category compare?

All MSD devices

MSD Catheter, Hemodialysis, Implanted: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · MSD

1in 2025

2007: 72008: 32009: 62010: 42011: 72012: 22013: 52014: 82015: 12016: 22017: 22018: 22019: 12020: 42021: 42025: 1
2007high 8 (2014) · low 0 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MSD

153in 2021

2007: 92 days median2008: 89 days median2009: 81 days median2010: 116 days median2011: 70 days median2013: 105 days median2014: 246 days median2020: 106 days median2021: 153 days median
2007high 246 (2014) · low 70 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MSD

1in 2013

2008: 472009: 492010: 112011: 242013: 12026 (partial year): 4, 4 Class I
2007high 49 (2009) · low 0 (2007)2026

Class I (4 since 2007) Class II/III not classified

Adverse event reports per year · MSD

1,054in 2025

2007: 1182008: 1742009: 1732010: 3062011: 2682012: 3672013: 3632014: 5062015: 5502016: 5322017: 4842018: 4632019: 6452020: 4012021: 5232022: 6102023: 5422024: 8412025: 1,054
2007high 1,054 (2025) · low 118 (2007)2025

MAUDE reports naming product code MSD, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20077920118
200838947174
200968149173
2010411611306
201177024268
20122—0367
201351051363
201482460506
20151—0550
20162—0532
20172—0484
20182—0463
20191—0645
202041060401
202141530523
20220—0610
20230—0542
20240—0841
20251—01,054
20260—4 (4)—

What is it indicated for?

The ProGuide Chronic Dialysis Catheter is indicated for use in attaining long-term vascular access for hemodialysis and apheresis.

It may be implanted percutaneously and is primarily placed in the internal jugular or subclavian vein of an adult patient.

Catheters greater than 40 cm are intended for femoral vein insertion.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K090148: Proguide Chronic Dialysis Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K090148

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026