Waveon WRX Bone Fixation System

K090304510(k) TraditionalCleared Aug 28, 2009203-day reviewClass II21 CFR 888.3030

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sonoma Orthopedic Products, Inc. · HRS Plate, Fixation, Bone

Cleared on Aug 28, 2009 as substantially equivalent to K071809 (Sonoma Orthopedic Products, Inc., 2008) after a 203-day review. Its family tree reaches back 7 generations to 1996.

Decided
Aug 28, 2009
Review
203 days
Class
Class II
Product code
HRS
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K962616 (1996). 11 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 7 generations backK962616 Synthes Dorsal Distal Radius Plate (DDRP) SystemSynthes (Usa) · 1996
  2. 6 generations backK982732 Synthes (Usa) Distal Radius Plate System (DRPS)Synthes · 1998
  3. 5 generations backK023007 Distal Radius Fracture Repair SystemHand Innovations, Inc. · 2002
  4. 4 generations backK030198 Hand Innovations, Inc. Distal Radius Fracture Repair SystemHand Innovations, Inc. · 2003
  5. 3 generations backK032705 Distal Radius Fracture Repair SystemHand Innovations, Inc. · 2003
  6. 2 generations backK042437 Dorsal Intramedullary PlateDeo Volente Orthopaedics, LLC · 2004
  7. 1 generation backK071809 Ensplintrx Bone Fixation SystemSonoma Orthopedic Products, Inc. · 2008
  8. This deviceK090304 Waveon WRX Bone Fixation SystemSonoma Orthopedic Products, Inc. · 2009
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K962616Synthes Dorsal Distal Radius Plate (DDRP) SystemSynthes (Usa)1996—
−6K982732Synthes (Usa) Distal Radius Plate System (DRPS)Synthes1998—
−5K023007Distal Radius Fracture Repair SystemHand Innovations, Inc.2002—
−4K030198Hand Innovations, Inc. Distal Radius Fracture Repair SystemHand Innovations, Inc.2003—
−3K032705Distal Radius Fracture Repair SystemHand Innovations, Inc.2003—
−2K042437Dorsal Intramedullary PlateDeo Volente Orthopaedics, LLC2004—
−1K071809Ensplintrx Bone Fixation SystemSonoma Orthopedic Products, Inc.2008—
0 (this device)K090304Waveon WRX Bone Fixation SystemSonoma Orthopedic Products, Inc.2009—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199610
200020
200410
FIG. 1 — Lineage of K090304, 1996–2009Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HRS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HRS device

  1. #1 K222465 Tyber Medical Anatomical Plating Systemscore 27.5 · 16 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K071809Ensplintrx Bone Fixation System
Summary page 1
…, Bone 21 CFR 888.3030, HRS Predicate Device Sonoma Orthopedic Products Inc. Ensplint Rx, K071809 Description of device The WavEon TM WRx configuration consists…
Sonoma Orthopedic Products, Inc.2008—

Also cleared against K071809: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 13 years and passes through 5 companies; a new generation was cleared every 1.5 years on median.
  • None of the 11 ancestors has a recall.
  • 1 other device also cites its predicate K071809.

How does its category compare?

All HRS devices

HRS Plate, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · HRS

54in 2025

2007: 352008: 352009: 472010: 492011: 432012: 592013: 562014: 762015: 562016: 442017: 572018: 402019: 462020: 482021: 402022: 472023: 402024: 542025: 542026 (partial year): 51
2007high 76 (2014) · low 35 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HRS

90in 2025

2007: 63 days median2008: 87 days median2009: 85 days median2010: 100 days median2011: 88 days median2012: 106 days median2013: 89 days median2014: 57 days median2015: 97 days median2016: 109 days median2017: 122 days median2018: 116 days median2019: 89 days median2020: 88 days median2021: 87 days median2022: 144 days median2023: 120 days median2024: 96 days median2025: 90 days median2026 (partial year): 82 days median
2007high 144 (2022) · low 57 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HRS

1in 2025

2007: 22008: 112009: 32010: 162011: 52012: 42013: 112015: 72016: 52017: 32018: 22019: 252020: 12021: 92022: 32023: 12025: 12026 (partial year): 3
2007high 25 (2019) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HRS

2,306in 2025

2007: 3392008: 3112009: 4352010: 4912011: 7732012: 1,6632013: 2,6432014: 2,4132015: 3,0952016: 2,2762017: 2,2202018: 2,6632019: 3,3592020: 2,7902021: 2,4422022: 1,7002023: 2,0492024: 1,8492025: 2,306
2007high 3,359 (2019) · low 311 (2008)2025

MAUDE reports naming product code HRS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200735632339
2008358711311
200947853435
20104910016491
201143885773
20125910641,663
20135689112,643
2014765702,413
2015569773,095
20164410952,276
20175712232,220
20184011622,663
20194689253,359
2020488812,790
2021408792,442
20224714431,700
20234012012,049
2024549601,849
2025549012,306
202651823—

What is it indicated for?

The WaveonTM WRx (WristRocketTM Distal Radius System) is intended to be used for the fixation of unstable distal radius fractures in which closed reduction is not suitable: * Joint destruction and/or subluxation visible on x-ray; * Osteotomy and repair of distal radius malunion with or without bone graft; * Non-displaced fractures. * Transverse fractures of the distal radius with or without comminution (e.g. AO classifications A2 and A3); * Transverse…

Read the full statement (140 words)

The WaveonTM WRx (WristRocketTM Distal Radius System) is intended to be used for the fixation of unstable distal radius fractures in which closed reduction is not suitable:

* Joint destruction and/or subluxation visible on x-ray;

* Osteotomy and repair of distal radius malunion with or without bone graft;

* Non-displaced fractures.

* Transverse fractures of the distal radius with or without comminution (e.g. AO classifications A2 and A3);

* Transverse fractures of the distal radius with an extension into the joint with or without comminution (e.g. AO classification C2 and C1 respectively);

* Failed fracture fixation with or without bone graft for the types of fractures above;

* The above types of fractures (i.e. AO classifications non-displaced transverse, A2, A3, C1 and C2) in which reduction has been lost following fixation with percutaneous pins with or without an external fixator.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K090304: Waveon WRX Bone Fixation System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K090304

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026