510(k) · Cleared
ClearedValved Tearway Introducer
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Medcomp · DYB Introducer, Catheter
Cleared on Sep 1, 2009 as substantially equivalent to K040150 (Medamicus, Inc., 2004) and 1 other predicate after a 196-day review. Its family tree reaches back 4 generations to 1993. 12 later devices descend from it.
- Decided
- Sep 1, 2009
- Review
- 196 days
- Class
- Class II
- Product code
- DYB
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 4 generations to K932323 (1993). 8 ancestors in all. 12 later devices descend from it, 4 citing it directly.
- Root · 4 generations backK932323 Percutaneous IntroducerMedamicus, Inc. · 1993
- 3 generations backK021004 Valved Peelable IntroducerMedamicus, Inc. · 2002
- 2 generations backK030905 Medamicus Flowguard Peelable IntroducerMedamicus, Inc. · 2003
- 1 generation backK040150 Modification to Medamicus Flowguard Peelable IntroducerMedamicus, Inc. · 2004
- This deviceK090394 Valved Tearway IntroducerMedcomp · 2009
- Descendant · cites it directly · 4 of its ownK122422 Pleurx Pleural Catheter System Pleurx Catheter Access Kit Pleurx…Care Fusion · 2012
- Descendant · 2 generations on · 2 of its ownK160437 PleurX Peritoneal Catheter SystemCare Fusion · 2016
- Descendant · cites it directly · 2 of its ownK120617 Ptfe Super Sheath IntroducerMartech Medical Products · 2012
- Descendant · cites it directly · 2 of its ownK121849 Pleurx Pleural Catheter System, Pleurx Catheter Access Kit, Pleurx…Care Fusion · 2012
- Descendant · 3 generations on · 1 of its ownK201155 PleurX Peritoneal Catheter SystemCare Fusion · 2020
Showing 5 of 12 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 12 · See all- K122422Pleurx Pleural Catheter System Pleurx Catheter Access Kit Pleurx Slide Valved Peelable…Care Fusion · 2012 · cites it directly4descendants
- K160437PleurX Peritoneal Catheter SystemCare Fusion · 2016 · 2 generations on2descendants
- K120617Ptfe Super Sheath IntroducerMartech Medical Products · 2012 · cites it directly2descendants
- K121849Pleurx Pleural Catheter System, Pleurx Catheter Access Kit, Pleurx Catheter Insertion…Care Fusion · 2012 · cites it directly2descendants
- K201155PleurX Peritoneal Catheter SystemCare Fusion · 2020 · 3 generations on1descendant
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K932323 | Percutaneous Introducer | Medamicus, Inc. | 1993 | — |
| −3 | K021004 | Valved Peelable Introducer | Medamicus, Inc. | 2002 | — |
| −2 | K030905 | Medamicus Flowguard Peelable Introducer | Medamicus, Inc. | 2003 | — |
| −1 | K040150 | Modification to Medamicus Flowguard Peelable Introducer | Medamicus, Inc. | 2004 | — |
| 0 (this device) | K090394 | Valved Tearway Introducer | Medcomp | 2009 | — |
| +1 | K122422 | Pleurx Pleural Catheter System Pleurx Catheter Access Kit Pleurx Slide Valved… | Care Fusion | 2012 | — |
| +2 | K160437 | PleurX Peritoneal Catheter System | Care Fusion | 2016 | — |
| +1 | K120617 | Ptfe Super Sheath Introducer | Martech Medical Products | 2012 | — |
| +1 | K121849 | Pleurx Pleural Catheter System, Pleurx Catheter Access Kit, Pleurx Catheter… | Care Fusion | 2012 | — |
| +3 | K201155 | PleurX Peritoneal Catheter System | Care Fusion | 2020 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2000 | 2 | 0 |
| 2002 | 1 | 0 |
| 2006 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2012 | 3 | 0 |
| 2013 | 2 | 0 |
| 2015 | 1 | 0 |
| 2016 | 3 | 0 |
| 2017 | 1 | 0 |
| 2020 | 1 | 0 |
| 2024 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DYB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DYB device
- #1 K251051 AuST Steerable Sheathscore 18.0 · 10 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K040150 | Modification to Medamicus Flowguard Peelable IntroducerSummary page 1…Introducer, Catheter Classification: DYB C.F.R. Section: 870.1340 C. Predicate Device: K040150 MedAmicus FlowGuard TM Peelable Introducer… | 2004 |
| * | K053092 | Medcomp Vascu-Sheath IISummary page 1…ice: K040150 MedAmicus FlowGuard TM Peelable Introducer K053092 Medcomp Vascu-Sheath® II Introducer Set D. Device Description: The Me… | 2006 |
What descends from it? (12)
See all 124 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K122422 | Pleurx Pleural Catheter System Pleurx Catheter Access Kit Pleurx Slide Valved Peelable… | 2012 | 4 |
| K120617 | Ptfe Super Sheath Introducer | 2012 | 2 |
| K121849 | Pleurx Pleural Catheter System, Pleurx Catheter Access Kit, Pleurx Catheter Insertion… | 2012 | 2 |
| K124046 | Valved Tearaway Introducer Generation II | 2013 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 16 years and passes through 2 companies; a new generation was cleared every 5.5 years on median.
- None of the 8 ancestors has a recall.
- Of its descendants, K122422 (Care Fusion, 2012) has gone furthest, with 4 descendants of its own.
- 4 other devices also cite its predicate K040150.
How does its category compare?
All DYB devicesDYB Introducer, Catheter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.
FDA decisions per year · DYB
16in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DYB
63in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DYB
3in 2025
Class I (48 since 2007) Class II/III not classified
Adverse event reports per year · DYB
4,539in 2025
MAUDE reports naming product code DYB, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 12 | 95 | 15 | 316 |
| 2008 | 17 | 37 | 9 | 423 |
| 2009 | 14 | 52 | 25 | 399 |
| 2010 | 18 | 123 | 18 | 445 |
| 2011 | 17 | 100 | 4 | 628 |
| 2012 | 22 | 128 | 3 | 898 |
| 2013 | 26 | 118 | 5 (1) | 743 |
| 2014 | 30 | 122 | 2 | 780 |
| 2015 | 17 | 129 | 2 (1) | 913 |
| 2016 | 19 | 95 | 45 (3) | 1,234 |
| 2017 | 24 | 70 | 22 (1) | 1,672 |
| 2018 | 19 | 156 | 1 | 1,903 |
| 2019 | 18 | 47 | 2 | 2,450 |
| 2020 | 9 | 49 | 21 (21) | 2,465 |
| 2021 | 12 | 78 | 6 | 2,835 |
| 2022 | 13 | 143 | 2 | 4,084 |
| 2023 | 15 | 55 | 10 | 3,775 |
| 2024 | 18 | 56 | 2 | 3,931 |
| 2025 | 16 | 63 | 3 | 4,539 |
| 2026 | 17 | 59 | 23 (21) | — |
What is it indicated for?
THE VALVED TEARAWAY INTRODUCERS ARE INTENDED TO OBTAIN CENTRAL VENOUS ACCESS TO FACILITATE CATHETER INSERTION INTO THE CENTRAL VENOUS SYSTEM.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K090394 · printed Nov 6, 2026
Cite this page
510(k) Report. “K090394: Valved Tearway Introducer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K090394
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026