# K090560: Conmed Linvatec Anodized Aluminum Sterilization Trays

- Pathway: 510(k) (Abbreviated)
- Applicant: Conmed Linvatec
- Decided: Jun 29, 2009 after 119 days
- Product code: KCT (Sterilization Wrap Containers, Trays, Cassettes & Other Accessories)
- Device class: 2
- Regulation: 21 CFR 880.6850
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 1 generation back to K080531 (2008). 1 ancestor in all.
1 later device descends from it; 1 cites it directly.
0 of 3 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K080531: Conmed Linvatec Microfracture Instrument Sterilization Tray, Conmed Linvatec (2008) Summary page 1.

## Most influential descendants
- K152969: Enhance Allograft Wedge Instrument Tray (2016), 0 descendants of its own

## Indications for use
ConMed Linvatec Anodized Aluminum Sterilization Trays is a family of containment devices for medical device sterilization. The PowerPro® Small System Sterilization Case (PRO5095) and the Hall® Sterilization Tray (PRO6000) are designed to hold a variety of powered ConMed Linvatec handpieces as well as attachments and/or accessories that may be used with the powered handpieces. Cannulated handpieces or attachments with an internal diameter not less than 0.031 inches (0.079cm) and a cannulated length no greater than 5.75 inches (14.61cm) and/or handpiece accessories such as pneumatic air supply hoses with a lumen not less than 0.187 inches (0.475 cm) in diameter and a cannulated length no greater than 15 feet (4.6 m) may be sterilized in this tray along with other non-cannulated, non-porous instruments. Sterilize the PowerPro® Small System Sterilization Case (PRO5095) and the Hall® Sterilization Tray (PRO6000) using the following parameters. Steam (wrapped), Pre-vacuum: 2700 F(1320C), 4 minutes exposure, 25 minutes dry cycle Steam (wrapped), Gravity: 270°F(132 0C), 15 minutes exposure, 35 minutes dry cycle CAUTION: Testing demonstrates that a minimum dry time of 35 minutes is required to prevent wet packs when using the gravity cycle. ConMed Linvatec Anodized Aluminum Sterilization Trays is a family of containment devices for medical device sterilization. The Hip Arthroscopy Master Tray is intended for use only with the following instruments: S210GSP Grasping Forceps 25.50014EL EL Liberator S21 OSRF Suture Retrieval 25.50016EL EL Rasp S21 0MSC Micro-scissors 06105SEL EL Crochet Hook. S21 OAFU Aggressor Forcep Up 8748EL EL Knot Pusher S21 OAFL Aggressor Forcep Left 9837 EL Hip Obturator S21 0AFR Aggressor Forcep Right A55-01 2-022 BMR Obturator, Blunt S21 0RFR Rotary Forcep Right A55-01 2-023 BMR Obturator, Trocar S210RGF Retrograde Forceps A55-012-113 BMR Drill Bit S21 ORFL Rotary- Forcep Left A55&01 2-130 ~BMR Bone. Punch C6171 EL EL Dril Guide Fishmouth A55-012-120 BMR Tap C61 72EL EL DrIl Guide Serrated GU1009EL EL Katana SC7900 Sloted Hip Cannula, 6.7mm GU1004EL EL Raven, Straight SC6900 Slotted Hip Cannula, 5.0mm 21.1001 EL EL Probe