510(k) Report

510(k) · Cleared

Cleared

Hanson Medical Facial Implants

K090803510(k) TraditionalCleared Jun 30, 2010463-day reviewClass II21 CFR 878.3680

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Hanson Medical, Inc. · FZE Prosthesis, Nose, Internal

Cleared on Jun 30, 2010 as substantially equivalent to K973573 (Hanson Medical, Inc., 1997) and 2 other predicates after a 463-day review. Its family tree reaches back 3 generations to 1995.

Decided
Jun 30, 2010
Review
463 days
Class
Class II
Product code
FZE
Recalls
None
Predicates
3

Its longest line of descent runs back 3 generations to K952705 (1995). 7 ancestors in all, the oldest K952707 (1995). No later device cites it as a predicate yet.

  1. Root · 3 generations backK952705 Spirit Ridge Nasal ImplantSpirit Ridge Technologies · 1995
  2. 2 generations backK971481 Duralastic Anatomical Nasal ImplantsAllied Biomedical Corp. · 1997
  3. 1 generation backK973573 Duralastic Anatomical Nasal ImplantsHanson Medical, Inc. · 1997
  4. This deviceK090803 Hanson Medical Facial ImplantsHanson Medical, Inc. · 2010
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K952705Spirit Ridge Nasal ImplantSpirit Ridge Technologies1995—
−2K971481Duralastic Anatomical Nasal ImplantsAllied Biomedical Corp.1997—
−1K973573Duralastic Anatomical Nasal ImplantsHanson Medical, Inc.1997—
0 (this device)K090803Hanson Medical Facial ImplantsHanson Medical, Inc.2010—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
199730
FIG. 1 — Lineage of K090803, 1995–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FZE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FZE device

  1. #1 K241253 Medicon Epiplating Systemscore 9.1 · 3 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K973573Duralastic Anatomical Nasal Implants
Summary page 3
…Radiological Health Enclosure TAB D INTENDED USE FORM 5 10(k) Number K 973573 Silicone Nasal Implant K 973574 Silicone Malar Implant K 973575 Silicone Chin Implant Device Name:…
Hanson Medical, Inc.1997—
*K973574Duralastic Anatomical Malar Implant
Summary page 3
…e 3 === TAB D INTENDED USE FORM 5 10(k) Number K 973573 Silicone Nasal Implant K 973574 Silicone Malar Implant K 973575 Silicone Chin Implant Device Name: Hanson Medical Facial Implants Indications fo…
Hanson Medical, Inc.1997—
*K973575Duralastic Anatomical Chin Implants
Summary page 3
…TAB D INTENDED USE FORM 5 10(k) Number K 973573 Silicone Nasal Implant K 973574 Silicone Malar Implant K 973575 Silicone Chin Implant Device Name: Hanson Medical Facial Implants Indications for use: Silicone Nasal Implant - For the augmen…
Hanson Medical, Inc.1997—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 15 years and passes through 3 companies; a new generation was cleared every 1.9 years on median.
  • None of the 7 ancestors has a recall.

How does its category compare?

All FZE devices

FZE Prosthesis, Nose, Internal: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · FZE

1in 2024

2007: 12009: 12010: 12016: 12024: 1
2007high 1 (2007) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FZE

Too few FZE 510(k)s in any year since 2007 to give a median.

Recalls per year · FZE

No recall names FZE since 2007.

Adverse event reports per year · FZE

13in 2025

2008: 22016: 72017: 132018: 122019: 242020: 232021: 322022: 302023: 142024: 262025: 13
2007high 32 (2021) · low 0 (2007)2025

MAUDE reports naming product code FZE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20080—02
20091—00
20101—00
20110—00
20120—00
20130—00
20140—00
20150—00
20161—07
20170—013
20180—012
20190—024
20200—023
20210—032
20220—030
20230—014
20241—026
20250—013
20260—0—

What is it indicated for?

Silicone Nasal Implant - For the augmentation or reconstruction of the nasal contour

Silicone Malar Implant - For the augmentation or reconstruction of the malar contour

Silicone Chin Implant -For the augmentation or reconstruction of the chin contour

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K090803: Hanson Medical Facial Implants.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K090803

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026