510(k) · Cleared
Recalled · Class II · 2013Pinnacle Destination Peripheral Guiding Sheath
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Terumo Medical Corp. · DYB Introducer, Catheter
Cleared on May 29, 2009 as substantially equivalent to K051601 (Terumo Medical Corp., 2005) and 1 other predicate after a 24-day review. Its family tree reaches back 4 generations to 1993. 2 of the 35 devices in its family, counting itself, have a Class I recall. 30 later devices descend from it. It has been recalled once.
- Decided
- May 29, 2009
- Review
- 24 days
- Class
- Class II
- Product code
- DYB
- Recalls
- 1
- Predicates
- 2
Its longest line of descent runs back 4 generations to K924607 (1993). 30 later devices descend from it, 8 citing it directly. 2 of the 35 devices in this family, counting this one, have a Class I recall.
- Root · 4 generations backK924607 Arrow Fischell Kink Resist Percut Sheath Intro SetArrow Intl., Inc. · 1993 · Recalled
- 3 generations backK012812 Carotid Guiding SheathTerumo Medical Corp. · 2001 · Recalled
- 2 generations backK051601 Pinnacle Destination Peripheral Guiding SheathTerumo Medical Corp. · 2005
- 1 generation backK080415 Device Modification to Pinnacle Destination Peripheral Guiding SheathTerumo Medical Corp. · 2008
- This deviceK091329 Pinnacle Destination Peripheral Guiding SheathTerumo Medical Corp. · 2009
- Descendant · cites it directly · 13 of its ownK142829 Flexor Tuohy-Borst Side-Arm Introducer, Ansel Modification; Flexor…Cook Incorporated · 2015 · Recalled (Class I)
- Descendant · cites it directly · 10 of its ownK100799 Fortress Introducer Sheath System Model 358813, 358814, 358815Contract Medical Intl. GmbH · 2011
- Descendant · 2 generations on · 6 of its ownK152913 GORE TIPS Set, GORE TIPS Sheath, GORE TIPS NeedleCreganna Medical Aslo Business AS Cregganna Tactx Medical · 2016 · Recalled
- Descendant · cites it directly · 6 of its ownK142357 DuraSheath Introducer Sheath SystemContract Medical International, GmbH · 2015
- Descendant · cites it directly · 5 of its ownK181463 DuraSheath Introducer Sheath SystemContract Medical International, GmbH · 2018
Showing 5 of 30 descendants. See all descendants
Descendants cleared per year
Class I recalls in this family
Most influential descendants
Showing 5 of 30 · See all- K142829Flexor Tuohy-Borst Side-Arm Introducer, Ansel Modification; Flexor Check-Flo Introducer…Cook Incorporated · 2015 · cites it directly13descendants
- K100799Fortress Introducer Sheath System Model 358813, 358814, 358815Contract Medical Intl. GmbH · 2011 · cites it directly10descendants
- K152913GORE TIPS Set, GORE TIPS Sheath, GORE TIPS NeedleCreganna Medical Aslo Business AS Cregganna Tactx Medical · 2016 · 2 generations on6descendants
- K142357DuraSheath Introducer Sheath SystemContract Medical International, GmbH · 2015 · cites it directly6descendants
- K181463DuraSheath Introducer Sheath SystemContract Medical International, GmbH · 2018 · cites it directly5descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K924607 | Arrow Fischell Kink Resist Percut Sheath Intro Set | Arrow Intl., Inc. | 1993 | 3 |
| −3 | K012812 | Carotid Guiding Sheath | Terumo Medical Corp. | 2001 | 1 |
| −2 | K051601 | Pinnacle Destination Peripheral Guiding Sheath | Terumo Medical Corp. | 2005 | — |
| −1 | K080415 | Device Modification to Pinnacle Destination Peripheral Guiding Sheath | Terumo Medical Corp. | 2008 | — |
| 0 (this device) | K091329 | Pinnacle Destination Peripheral Guiding Sheath | Terumo Medical Corp. | 2009 | — |
| +1 | K142829 | Flexor Tuohy-Borst Side-Arm Introducer, Ansel Modification; Flexor Check-Flo… | Cook Incorporated | 2015 | Class I |
| +1 | K100799 | Fortress Introducer Sheath System Model 358813, 358814, 358815 | Contract Medical Intl. GmbH | 2011 | — |
| +2 | K152913 | GORE TIPS Set, GORE TIPS Sheath, GORE TIPS Needle | Creganna Medical Aslo Business AS Cregganna Tactx Medical | 2016 | 1 |
| +1 | K142357 | DuraSheath Introducer Sheath System | Contract Medical International, GmbH | 2015 | — |
| +1 | K181463 | DuraSheath Introducer Sheath System | Contract Medical International, GmbH | 2018 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2010 | 1 | 0 |
| 2011 | 1 | 0 |
| 2015 | 5 | 2 |
| 2016 | 4 | 0 |
| 2017 | 2 | 0 |
| 2018 | 2 | 0 |
| 2020 | 3 | 0 |
| 2021 | 4 | 0 |
| 2022 | 2 | 0 |
| 2023 | 2 | 0 |
| 2024 | 1 | 0 |
| 2025 | 3 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DYB device
- #1 K251051 AuST Steerable Sheathscore 18.0 · 10 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K051601 | Pinnacle Destination Peripheral Guiding SheathSummary page 3…valent in intended use, design, principle of operation / technology, materials and performance to the Pinnacle® Destination® Peripheral Guiding Sheath (K05 1601 and K0804 15), which is manufactured by Terumo Medical Corporation. Differences between the devices do not raise any iss… | 2005 |
| * | K080415 | Device Modification to Pinnacle Destination Peripheral Guiding SheathSummary page 1…by Terumo Medical Corporation. The Pinnacle® Destination® Peripheral Guiding Sheath is cleared through the premarket notification process (KO51601 and K080415). C. INTENDED USE The Pinnacle® Destination® Peripheral Guiding Sheath is designed to be used for the i… | 2008 |
What descends from it? (30)
See all 308 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K142829 | Flexor Tuohy-Borst Side-Arm Introducer, Ansel Modification; Flexor Check-Flo Introducer… Class I | 2015 | 13 |
| K100799 | Fortress Introducer Sheath System Model 358813, 358814, 358815 | 2011 | 10 |
| K142357 | DuraSheath Introducer Sheath System | 2015 | 6 |
| K181463 | DuraSheath Introducer Sheath System | 2018 | 5 |
| K142819 | Shuttle SL Flexor Tuohy-Borst Side-Arm Introducer Set | 2015 | 1 |
| K172995 | Destination Carotid Guiding Sheath, Destination Peripheral Guiding Sheath, Destination… | 2017 | 0 |
| K150186 | Chariot Guiding Sheath Class I | 2015 | 0 |
| K101625 | Cohen Crossover Catheter | 2010 | 0 |
Has anything in its family been recalled? (2 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| May 30, 2013 | Class II | Z-1611-2013 | Error in labeling | Medical devices were incorrectly labeled with extended expiration dates. |
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K150186Chariot Guiding SheathBoston Scientific Corp · 2015 · Cites it directly · ◆ in the 2015 descendants bar of FIG. 11 Class I recall
- K142829Flexor Tuohy-Borst Side-Arm Introducer, Ansel Modification; Flexor Check-Flo Introducer, Ansel Modification…Cook Incorporated · 2015 · Cites it directly · ◆ in the 2015 descendants bar of FIG. 121 Class I recalls
What does this lineage say?
- The line of descent spans 16 years and passes through 2 companies; a new generation was cleared every 3.7 years on median.
- 2 of the 4 ancestors have a recall of any class.
- Of its descendants, K142829 (Cook Incorporated, 2015) has gone furthest, with 13 descendants of its own.
- 3 other devices also cite its predicate K051601.
How does its category compare?
All DYB devicesDYB Introducer, Catheter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.
FDA decisions per year · DYB
16in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DYB
63in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DYB
3in 2025
Class I (48 since 2007) Class II/III not classified
Adverse event reports per year · DYB
4,539in 2025
MAUDE reports naming product code DYB, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 12 | 95 | 15 | 316 |
| 2008 | 17 | 37 | 9 | 423 |
| 2009 | 14 | 52 | 25 | 399 |
| 2010 | 18 | 123 | 18 | 445 |
| 2011 | 17 | 100 | 4 | 628 |
| 2012 | 22 | 128 | 3 | 898 |
| 2013 | 26 | 118 | 5 (1) | 743 |
| 2014 | 30 | 122 | 2 | 780 |
| 2015 | 17 | 129 | 2 (1) | 913 |
| 2016 | 19 | 95 | 45 (3) | 1,234 |
| 2017 | 24 | 70 | 22 (1) | 1,672 |
| 2018 | 19 | 156 | 1 | 1,903 |
| 2019 | 18 | 47 | 2 | 2,450 |
| 2020 | 9 | 49 | 21 (21) | 2,465 |
| 2021 | 12 | 78 | 6 | 2,835 |
| 2022 | 13 | 143 | 2 | 4,084 |
| 2023 | 15 | 55 | 10 | 3,775 |
| 2024 | 18 | 56 | 2 | 3,931 |
| 2025 | 16 | 63 | 3 | 4,539 |
| 2026 | 17 | 59 | 23 (21) | — |
What is it indicated for?
The Pinnacle® Destination® Peripheral Guiding Sheath is designed to be used for the
introduction of interventional and diagnostic devices into the human vasculature,
including but not limited to lower extremity access via a contralateral approach.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K091329 · printed Nov 4, 2026
Cite this page
510(k) Report. “K091329: Pinnacle Destination Peripheral Guiding Sheath.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K091329
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026