510(k) Report

510(k) · Cleared

Recalled · Class II · 2018

Advance 35LP Low Profile Pta Balloon Dilatation Catheter

K091527510(k) SpecialCleared Jun 12, 200917-day reviewClass II21 CFR 870.1250Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cook, Inc. · DQY Catheter, Percutaneous

Cleared on Jun 12, 2009 after a 17-day review. The FDA summary names its predicate without a number. 1 of the 3 devices in its family, counting itself, has a Class I recall. 2 later devices descend from it. It has been recalled once.

Decided
Jun 12, 2009
Review
17 days
Class
Class II
Product code
DQY
Recalls
1
Predicates
0

2 later devices descend from it, 2 citing it directly. 1 of the 3 devices in this family, counting this one, has a Class I recall.

Descendants, by year cleared 2013: 1 descendant cleared2015: 1 descendant cleared, 1 with a Class I recall120052010201520202025
  1. This deviceK091527 Advance 35LP Low Profile Pta Balloon Dilatation CatheterCook, Inc. · 2009
  2. Descendant · cites it directly · 1 of its ownK132020 Advance 34LP Low Profile Pta Balloon Dilatation CatheterCook, Inc. · 2013
  3. Descendant · cites it directly · 0 of its ownK141322 Advance Enforcer 35 Focal Force Pta Balloon CatheterCook Incorporated · 2015 · Recalled (Class I)

Class I recalls in this family

Most influential descendants

Showing 2 of 2 · See all
  • K132020Advance 34LP Low Profile Pta Balloon Dilatation CatheterCook, Inc. · 2013 · cites it directly1descendant
  • K141322Advance Enforcer 35 Focal Force Pta Balloon CatheterCook Incorporated · 2015 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K091527Advance 35LP Low Profile Pta Balloon Dilatation CatheterCook, Inc.2009—
+1K132020Advance 34LP Low Profile Pta Balloon Dilatation CatheterCook, Inc.2013—
+1K141322Advance Enforcer 35 Focal Force Pta Balloon CatheterCook Incorporated2015Class I

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
201511
FIG. 1 — Lineage of K091527, 2009–2015Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQY device

  1. #1 K234115 APRO 55 Catheterscore 17.5 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—PTA Balloon Catheter
Named without a submission number
—

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K132020Advance 34LP Low Profile Pta Balloon Dilatation CatheterCook, Inc.20131
K141322Advance Enforcer 35 Focal Force Pta Balloon Catheter Class ICook Incorporated20150

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 16, 2018Class IIZ-1521-2018Labeling mix-upsIncorrect product labeling. Product labeled as 6mm x 2cm balloon are packaged with a 4mm x 4 cm balloon label and vice-versa.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K141322Advance Enforcer 35 Focal Force Pta Balloon CatheterCook Incorporated · 2015 · Cites it directly · ◆ in the 2015 descendants bar of FIG. 13 Class I recalls

What does this lineage say?

  • Of its descendants, K132020 (Cook, Inc., 2013) has gone furthest, with 1 descendant of its own.

How does its category compare?

All DQY devices

DQY Catheter, Percutaneous: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · DQY

21in 2025

2007: 162008: 312009: 372010: 222011: 362012: 302013: 322014: 192015: 272016: 222017: 262018: 252019: 302020: 202021: 182022: 182023: 182024: 162025: 212026 (partial year): 11
2007high 37 (2009) · low 16 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQY

115in 2025

2007: 85 days median2008: 66 days median2009: 73 days median2010: 74 days median2011: 71 days median2012: 87 days median2013: 92 days median2014: 127 days median2015: 118 days median2016: 117 days median2017: 113 days median2018: 106 days median2019: 111 days median2020: 120 days median2021: 81 days median2022: 74 days median2023: 114 days median2024: 87 days median2025: 115 days median2026 (partial year): 30 days median
2007high 127 (2014) · low 66 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQY

1in 2025

2007: 62008: 122009: 172010: 322011: 62012: 22013: 36, 1 Class I2014: 32015: 32016: 22, 7 Class I2017: 82018: 22019: 12020: 22021: 22023: 172024: 12025: 1, 1 Class I2026 (partial year): 2, 1 Class I
2007high 36 (2013) · low 0 (2022)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · DQY

3,056in 2025

2007: 3132008: 4962009: 8192010: 1,2932011: 1,2112012: 1,1912013: 1,3522014: 1,4972015: 2,3372016: 2,2522017: 2,4892018: 2,8552019: 2,9022020: 2,8892021: 3,0062022: 2,6432023: 3,0492024: 3,1902025: 3,056
2007high 3,190 (2024) · low 313 (2007)2025

MAUDE reports naming product code DQY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200716856313
2008316612496
2009377317819
20102274321,293
2011367161,211
2012308721,191
2013329236 (1)1,352
20141912731,497
20152711832,337
20162211722 (7)2,252
20172611382,489
20182510622,855
20193011112,902
20202012022,889
2021188123,006
2022187402,643
202318114173,049
2024168713,190
2025211151 (1)3,056
202611302 (1)—

What is it indicated for?

For percutaneous transluminal angioplasty (PTA) of lesions in peripheral arteries including iliac, renal, popliteal, infrapopliteal, femoral and iliofemoral as well as obstructive lesions of native or synthetic arteriovenous dialysis fistulae.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K091527: Advance 35LP Low Profile Pta Balloon Dilatation Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K091527

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026