510(k) Report

510(k) · Cleared

Cleared

Disposable SPO2 Sensor M1134A

K091572510(k) TraditionalCleared Sep 22, 2009112-day reviewClass II21 CFR 870.2700

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · DQA Oximeter

Cleared on Sep 22, 2009 as substantially equivalent to K052377 (Philips Medizin Systeme Boeblingen GmbH, 2005) and 1 other predicate after a 112-day review. Its family tree reaches back 10 generations to 1994. 38 later devices descend from it.

Decided
Sep 22, 2009
Review
112 days
Class
Class II
Product code
DQA
Recalls
None
Predicates
2

Its longest line of descent runs back 10 generations to K941811 (1994). 43 ancestors in all, the oldest K872781 (1987). 38 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2005: 1 other ancestor2004: 2 other ancestors2000: 8 other ancestors1998: 3 other ancestors1993: 2 other ancestors1990: 2 other ancestors1989: 1 other ancestor1997: 2 other ancestors1999: 3 other ancestors1996: 1 other ancestor1995: 3 other ancestors1994: 1 other ancestor1992: 3 other ancestors1987: 1 other ancestor2010: 1 descendant cleared2011: 1 descendant cleared2013: 2 descendants cleared2023: 4 descendants cleared2020: 3 descendants cleared2014: 1 descendant cleared2015: 1 descendant cleared2022: 4 descendants cleared2018: 2 descendants cleared2017: 1 descendant cleared2025: 6 descendants cleared2019: 2 descendants cleared2024: 6 descendants cleared2021: 2 descendants cleared2026: 2 descendants clearedK941811 · HP M1175A, M1176A, Component Monitoring System · Hewlett-Packard Co. · 1994K960934 · HP M1205A Omnicare Component Monitor System Model 24 · Hewlett-Packard Co. · 1996×3: 3 generations cleared close together, K981376 (1999), K990125 (1999), K990972 (1999) K013199 · Philips Component Compact Monitor,Model M1275B, Philips Compenent Rack, Model M1276B · Philips Medical Systems, Inc. · 2001K021300 · Modification of Philips Component Compact Monitor, Release a.03, Model M1275B · Philips Medical Systems · 2002K030973 · Picosat II SPO2 Pulse Oximetry Module · Philips Medical Systems · 2003K062605 · Philips SPO2 Reusable Sensor, Models M1196A and M1196T · Philips Medical Systems · 2006K063783 · Philips Reusable SPO2 Sensors M1191T, M1192T and M1193T, Clip Sensor M1196T and Disposable SPO2 Sensors M1131A, M1132A · Philips Medical Systems, Inc. · 20071990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 3 other ancestors3 generations back: 5 other ancestors4 generations back: 1 other ancestor5 generations back: 20 other ancestors6 generations back: 3 other ancestors 1 generation forward: 1 descendant2 generations forward: 2 descendants3 generations forward: 1 descendant4 generations forward: 5 descendants5 generations forward: 5 descendants6 generations forward: 4 descendants7 generations forward: 4 descendants8 generations forward: 5 descendants9 generations forward: 5 descendants10 generations forward: 6 descendants K063783 · Philips Reusable SPO2 Sensors M1191T, M1192T and M1193T, Clip Sensor M1196T and Disposable SPO2 Sensors M1131A, M1132A · Philips Medical Systems, Inc. · 2007K062605 · Philips SPO2 Reusable Sensor, Models M1196A and M1196T · Philips Medical Systems · 2006K030973 · Picosat II SPO2 Pulse Oximetry Module · Philips Medical Systems · 2003K021300 · Modification of Philips Component Compact Monitor, Release a.03, Model M1275B · Philips Medical Systems · 2002K013199 · Philips Component Compact Monitor,Model M1275B, Philips Compenent Rack, Model M1276B · Philips Medical Systems, Inc. · 2001K990972 · HP Viridia Component Monitoring System, HP Viridia CMS 24/26, HP Viridia Multi-Measurement Server and Compact Portable T · Hewlett-Packard GmbH · 1999K990125 · HP Viridia Component Monitoring System, Model Rev. K · Hewlett-Packard GmbH · 1999K981376 · Hewlett-Packard M1205A Viridia 24 CT · Hewlett-Packard Co. · 1999K960934 · HP M1205A Omnicare Component Monitor System Model 24 · Hewlett-Packard Co. · 1996K941811 · HP M1175A, M1176A, Component Monitoring System · Hewlett-Packard Co. · 1994−10−50+5+10
  1. Root · 10 generations backK941811 HP M1175A, M1176A, Component Monitoring SystemHewlett-Packard Co. · 1994
  2. 6 generations between
  3. 3 generations backK030973 Picosat II SPO2 Pulse Oximetry ModulePhilips Medical Systems · 2003
  4. 2 generations backK062605 Philips SPO2 Reusable Sensor, Models M1196A and M1196TPhilips Medical Systems · 2006
  5. 1 generation backK063783 Philips Reusable SPO2 Sensors M1191T, M1192T and M1193T, Clip Sensor…Philips Medical Systems, Inc. · 2007
  6. This deviceK091572 Disposable SPO2 Sensor M1134APhilips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2009
  7. Descendant · cites it directly · 37 of its ownK101600 Intellivue CL SP02 Pod Model 865215, Intellivue CL NBP Pod Model…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2010
  8. Descendant · 2 generations on · 36 of its ownK111905 Intellivue Guardian Software Model 866009, Intellivue CL SP02 Pod…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2011
  9. Descendant · 3 generations on · 35 of its ownK122223 New: Intellivue CL Respiration Pod New: Specialized Assessory…Philips Medizin Systeme Boeblingen GmbH · 2013
  10. Descendant · 4 generations on · 24 of its ownK151736 Philips IntelliVue GuardianSoftwarePhilips Medizin Systeme Boblingen GmbH · 2015
  11. Descendant · 5 generations on · 23 of its ownK161767 Philips IntelliVue GuardianSoftwarePhilips Medizin Systeme Boeblingen GmbH · 2017
Show all 10 generations
  1. Root · 10 generations backK941811 HP M1175A, M1176A, Component Monitoring SystemHewlett-Packard Co. · 1994
  2. 9 generations backK960934 HP M1205A Omnicare Component Monitor System Model 24Hewlett-Packard Co. · 1996
  3. 8 generations backK981376 Hewlett-Packard M1205A Viridia 24 CTHewlett-Packard Co. · 1999
  4. 7 generations backK990125 HP Viridia Component Monitoring System, Model Rev. KHewlett-Packard GmbH · 1999
  5. 6 generations backK990972 HP Viridia Component Monitoring System, HP Viridia CMS 24/26, HP…Hewlett-Packard GmbH · 1999
  6. 5 generations backK013199 Philips Component Compact Monitor,Model M1275B, Philips Compenent…Philips Medical Systems, Inc. · 2001
  7. 4 generations backK021300 Modification of Philips Component Compact Monitor, Release a.03…Philips Medical Systems · 2002
  8. 3 generations backK030973 Picosat II SPO2 Pulse Oximetry ModulePhilips Medical Systems · 2003
  9. 2 generations backK062605 Philips SPO2 Reusable Sensor, Models M1196A and M1196TPhilips Medical Systems · 2006
  10. 1 generation backK063783 Philips Reusable SPO2 Sensors M1191T, M1192T and M1193T, Clip Sensor…Philips Medical Systems, Inc. · 2007
  11. This deviceK091572 Disposable SPO2 Sensor M1134APhilips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2009

Showing 5 of 38 descendants. See all descendants

Descendants cleared per year

2010: 12011: 12013: 22014: 12015: 12017: 12018: 22019: 22020: 32021: 22022: 42023: 42024: 62025: 62026: 2
2010high 6 (2024) · low 0 (2012)2026

Most influential descendants

Showing 5 of 38 · See all
  • K101600Intellivue CL SP02 Pod Model 865215, Intellivue CL NBP Pod Model 865216, Intellivue…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2010 · cites it directly37descendants
  • K111905Intellivue Guardian Software Model 866009, Intellivue CL SP02 Pod Model 865215…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2011 · 2 generations on36descendants
  • K122223New: Intellivue CL Respiration Pod New: Specialized Assessory: Mobile CL Resp Attachment…Philips Medizin Systeme Boeblingen GmbH · 2013 · 3 generations on35descendants
  • K151736Philips IntelliVue GuardianSoftwarePhilips Medizin Systeme Boblingen GmbH · 2015 · 4 generations on24descendants
  • K161767Philips IntelliVue GuardianSoftwarePhilips Medizin Systeme Boeblingen GmbH · 2017 · 5 generations on23descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K941811HP M1175A, M1176A, Component Monitoring SystemHewlett-Packard Co.1994—
−9K960934HP M1205A Omnicare Component Monitor System Model 24Hewlett-Packard Co.1996—
−8K981376Hewlett-Packard M1205A Viridia 24 CTHewlett-Packard Co.1999—
−7K990125HP Viridia Component Monitoring System, Model Rev. KHewlett-Packard GmbH1999—
−6K990972HP Viridia Component Monitoring System, HP Viridia CMS 24/26, HP Viridia…Hewlett-Packard GmbH1999—
−5K013199Philips Component Compact Monitor,Model M1275B, Philips Compenent Rack, Model…Philips Medical Systems, Inc.2001—
−4K021300Modification of Philips Component Compact Monitor, Release a.03, Model M1275BPhilips Medical Systems2002—
−3K030973Picosat II SPO2 Pulse Oximetry ModulePhilips Medical Systems2003—
−2K062605Philips SPO2 Reusable Sensor, Models M1196A and M1196TPhilips Medical Systems2006—
−1K063783Philips Reusable SPO2 Sensors M1191T, M1192T and M1193T, Clip Sensor M1196T…Philips Medical Systems, Inc.2007—
0 (this device)K091572Disposable SPO2 Sensor M1134APhilips Medizinsysteme Boeblingen GmbH, Cardiac AN2009—
+1K101600Intellivue CL SP02 Pod Model 865215, Intellivue CL NBP Pod Model 865216…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN2010—
+2K111905Intellivue Guardian Software Model 866009, Intellivue CL SP02 Pod Model…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN2011—
+3K122223New: Intellivue CL Respiration Pod New: Specialized Assessory: Mobile CL Resp…Philips Medizin Systeme Boeblingen GmbH2013—
+4K151736Philips IntelliVue GuardianSoftwarePhilips Medizin Systeme Boblingen GmbH2015—
+5K161767Philips IntelliVue GuardianSoftwarePhilips Medizin Systeme Boeblingen GmbH2017—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
198910
199020
199230
199320
199410
199530
199610
199720
199830
199930
200080
200420
200510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201010
201110
201320
201410
201510
201710
201820
201920
202030
202120
202240
202340
202460
202560
202620
FIG. 1 — Lineage of K091572, 1994–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQA device

  1. #1 K221282 Empatica Health Monitoring Platformscore 20.1 · 38 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K052377Philips Disposable SPO2 Sensors MII32A and M1133A.
Summary page 1
…Oximeter 74 3. The modified device is substantially equivalent to previously, cleared Philips disposable Sp0 2 sensor M1133A (K052377, K063783) The modified device uses adhesive-free material (adhesive-free skins) which covers the optical part…
Philips Medizin Systeme Boeblingen GmbH2005—
*K063783Philips Reusable SPO2 Sensors M1191T, M1192T and M1193T, Clip Sensor M1196T and…
Summary page 1
…er 74 3. The modified device is substantially equivalent to previously, cleared Philips disposable Sp0 2 sensor M1133A (K052377, K063783) The modified device uses adhesive-free material (adhesive-free skins) which covers the optical parts of the…
Philips Medical Systems, Inc.2007—

Also cleared against K052377: 1 other device →

What descends from it? (38)

See all 38

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K101600Intellivue CL SP02 Pod Model 865215, Intellivue CL NBP Pod Model 865216, Intellivue…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN201037

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 15 years and passes through 5 companies; a new generation was cleared every 2.1 years on median.
  • 1 of the 43 ancestors has a recall of any class.
  • Of its descendants, K101600 (Philips Medizinsysteme Boeblingen GmbH, Cardiac AN, 2010) has gone furthest, with 37 descendants of its own.
  • 1 other device also cites its predicate K052377.

How does its category compare?

All DQA devices

DQA Oximeter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · DQA

15in 2025

2007: 202008: 222009: 352010: 292011: 152012: 142013: 152014: 112015: 132016: 142017: 92018: 182019: 192020: 152021: 102022: 202023: 132024: 142025: 152026 (partial year): 8
2007high 35 (2009) · low 9 (2017)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQA

182in 2025

2007: 122 days median2008: 97 days median2009: 117 days median2010: 127 days median2011: 195 days median2012: 120 days median2013: 182 days median2014: 175 days median2015: 158 days median2016: 246 days median2017: 200 days median2018: 260 days median2019: 158 days median2020: 126 days median2021: 174 days median2022: 265 days median2023: 317 days median2024: 285 days median2025: 182 days median2026 (partial year): 187 days median
2007high 317 (2023) · low 97 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQA

3in 2024

2007: 62008: 52009: 292010: 42011: 12014: 22015: 12018: 322024: 3
2007high 32 (2018) · low 0 (2012)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DQA

399in 2025

2007: 3252008: 3122009: 2812010: 1852011: 1642012: 3222013: 4682014: 1,1242015: 2,0822016: 1,7752017: 1,1902018: 6942019: 5482020: 4262021: 5532022: 4782023: 3922024: 5452025: 399
2007high 2,082 (2015) · low 164 (2011)2025

MAUDE reports naming product code DQA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007201226325
200822975312
20093511729281
2010291274185
2011151951164
2012141200322
2013151820468
20141117521,124
20151315812,082
20161424601,775
2017920001,190
20181826032694
2019191580548
2020151260426
2021101740553
2022202650478
2023133170392
2024142853545
2025151820399
202681870—

What is it indicated for?

The Philips 'disposable SpO2 sensor M1134A is indicated for use by health care professionals whenever there is a need for acquiring non-invasively the arterial oxygen saturation to support the measurement of oxygen saturation. Intended for monitoring, recording, and alarming of the physiological parameters arterial oxygen saturation (SpO2) and pulse rate of adults, infants, and neonates in a healthcare environment and during transport inside and outside of healthcare environments.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K091572: Disposable SPO2 Sensor M1134A.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K091572

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026