510(k) Report

510(k) · Cleared

Recalled · Class II · 2024

Cryopatch SG Pulmonary Hemi-Artery; Trunk; Branch

K091626510(k) TraditionalCleared Aug 7, 200965-day reviewClass II21 CFR 870.3470Recalls 3

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cryolife, Inc. · DXZ Patch, Pledget And Intracardiac, Petp, Ptfe, Polypropylene

Cleared on Aug 7, 2009 as substantially equivalent to K083106 (Cryolife, Inc., 2009) after a 65-day review. Its family tree reaches back 1 generation to 2009. 1 later device descends from it. It has been recalled 3 times.

Decided
Aug 7, 2009
Review
65 days
Class
Class II
Product code
DXZ
Recalls
3
Predicates
1

Its longest line of descent runs back 1 generation to K083106 (2009). 1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2010: 1 descendant clearedK083106 · Cryovalve SG Pulmonary Valve and Conduit · Cryolife, Inc. · 2009 · recalled20052010201520202025
Descendants, by generation 1 generation forward: 1 descendant K083106 · Cryovalve SG Pulmonary Valve and Conduit · Cryolife, Inc. · 2009 · recalled0
  1. Root · 1 generation backK083106 Cryovalve SG Pulmonary Valve and ConduitCryolife, Inc. · 2009 · Recalled
  2. This deviceK091626 Cryopatch SG Pulmonary Hemi-Artery; Trunk; BranchCryolife, Inc. · 2009
  3. Descendant · cites it directly · 0 of its ownK101866 Cryopatch SG Pulmonary Human Cardiac PatchCryolife, Inc. · 2010 · Recalled

Most influential descendants

Showing 1 of 1 · See all
  • K101866Cryopatch SG Pulmonary Human Cardiac PatchCryolife, Inc. · 2010 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K083106Cryovalve SG Pulmonary Valve and ConduitCryolife, Inc.20091
0 (this device)K091626Cryopatch SG Pulmonary Hemi-Artery; Trunk; BranchCryolife, Inc.2009—
+1K101866Cryopatch SG Pulmonary Human Cardiac PatchCryolife, Inc.20105

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201010
FIG. 1 — Lineage of K091626, 2009–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXZ device

  1. #1 K240775 PeriBeam® Pericardial Membranescore 9.2 · 1 generation · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K083106Cryovalve SG Pulmonary Valve and Conduit
Summary page 1
…Cy~f- rc 038 2V0 H Conduit). Kennesaw.. GA K083 106 02r062009 Device Description: The CryoPatce- SG Pulmonary Hun an Cardiac Patch is derived from human pulmonary valv'e and art…
Cryolife, Inc.20091
*—MatrACELL Pulmonary Artery Patch Allograft
Named without a submission number
—

Also cleared against K083106: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K101866Cryopatch SG Pulmonary Human Cardiac PatchCryolife, Inc.20100

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 28, 2024Class IIZ-2532-2024Under Investigation by firmGrafts were found to have been approved, released, shipped and implanted with an invalid test results.
Sep 6, 2018Class IIZ-0121-2019Labeling mix-upsThe conduit length and branch length of a SG Pulmonary Hemi-Artery were switched on the product labeling. The graft labeling indicates the conduit length is 1.0cm and the branch length is 4.5cm.
Nov 21, 2016Class IIZ-1219-2019Release of Material/Component prior to receiving test resultsThe device is recalled due to donor ineligibility of released human tissue. The firm received information that the tissue donor's blood culture tested positive for Enterobacter cloacae.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has a recall.
  • Of its descendants, K101866 (Cryolife, Inc., 2010) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K083106.

How does its category compare?

All DXZ devices

DXZ Patch, Pledget And Intracardiac, Petp, Ptfe, Polypropylene: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · DXZ

1in 2025

2007: 12008: 22009: 12010: 32011: 22012: 12013: 12014: 32015: 22016: 22017: 12020: 12025: 1
2007high 3 (2010) · low 0 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXZ

106in 2014

2010: 91 days median2014: 106 days median
2007high 106 (2014) · low 91 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXZ

2in 2025

2010: 22011: 22013: 22018: 12020: 12023: 22025: 2, 2 Class I2026 (partial year): 1
2007high 2 (2010) · low 0 (2007)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · DXZ

119in 2025

2007: 502008: 62009: 1092010: 812011: 472012: 212013: 692014: 932015: 1712016: 662017: 302018: 442019: 552020: 1212021: 802022: 772023: 402024: 492025: 119
2007high 171 (2015) · low 6 (2008)2025

MAUDE reports naming product code DXZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—050
20082—06
20091—0109
2010391281
20112—247
20121—021
20131—269
20143106093
20152—0171
20162—066
20171—030
20180—144
20190—055
20201—1121
20210—080
20220—077
20230—240
20240—049
20251—2 (2)119
20260—1—

What is it indicated for?

Indicated for repair or reconstruction of the right ventricular outflow tract.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K091626: Cryopatch SG Pulmonary Hemi-Artery; Trunk; Branch.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K091626

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026