510(k) Report

510(k) · Cleared

Cleared

Nobelprocera ZI Abutment

K091904510(k) TraditionalCleared Sep 25, 200992-day reviewClass II21 CFR 872.3630

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Nobel Biocare AB · NHA Abutment, Implant, Dental, Endosseous

Cleared on Sep 25, 2009 as substantially equivalent to K042658 (Nobel Biocare Uas, Inc., 2004) and 1 other predicate after a 92-day review. Its family tree reaches back 8 generations to 1995. 35 later devices descend from it.

Decided
Sep 25, 2009
Review
92 days
Class
Class II
Product code
NHA
Recalls
None
Predicates
2

Its longest line of descent runs back 8 generations to K944964 (1995). 63 ancestors in all, the oldest K871863 (1987). 35 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2004: 2 other ancestors2003: 2 other ancestors1998: 2 other ancestors1996: 6 other ancestors1994: 9 other ancestors2002: 3 other ancestors2001: 4 other ancestors1999: 4 other ancestors1997: 2 other ancestors1989: 1 other ancestor1987: 1 other ancestor2000: 1 other ancestor1995: 6 other ancestors1993: 9 other ancestors1991: 1 other ancestor1990: 2 other ancestors2014: 4 descendants cleared2016: 2 descendants cleared2019: 6 descendants cleared2017: 1 descendant cleared2020: 6 descendants cleared2018: 3 descendants cleared2022: 4 descendants cleared2024: 3 descendants cleared2026: 2 descendants cleared2021: 2 descendants cleared2023: 1 descendant cleared2025: 1 descendant clearedK944964 · Branemark System Miruscone Abutment System · Nobelpharma USA, Inc. · 1995×2: 2 generations cleared close together, K961728 (1996), K962403 (1996) K971706 · Tiadapt Abutment System · Nobel Biocare Uas, Inc. · 1997K974150 · Procera Preparable Abutment System · Nobel Biocare Uas, Inc. · 1998 · recalledK032263 · 3I Patient-Specific Dental Abutment and Overdenture Bar · Implant Innovations, Inc. · 2004 · recalledK043042 · Procera Implant Bridge, Models 15-1001, 15-1002, 15-1051, 15-1052 · Nobel Biocare AB · 2004K090069 · Procera Implant Bridge Overdenture · Nobel Biocare AB · 20091990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 5 other ancestors3 generations back: 17 other ancestors4 generations back: 13 other ancestors5 generations back: 10 other ancestors6 generations back: 9 other ancestors 1 generation forward: 2 descendants2 generations forward: 10 descendants3 generations forward: 11 descendants4 generations forward: 10 descendants5 generations forward: 1 descendant6 generations forward: 1 descendant K090069 · Procera Implant Bridge Overdenture · Nobel Biocare AB · 2009K043042 · Procera Implant Bridge, Models 15-1001, 15-1002, 15-1051, 15-1052 · Nobel Biocare AB · 2004K032263 · 3I Patient-Specific Dental Abutment and Overdenture Bar · Implant Innovations, Inc. · 2004 · recalledK974150 · Procera Preparable Abutment System · Nobel Biocare Uas, Inc. · 1998 · recalledK971706 · Tiadapt Abutment System · Nobel Biocare Uas, Inc. · 1997K962403 · Noblepharma Wide Accessories · Nobelpharma USA, Inc. · 1996K961728 · Miruscone Abutment System · Nobelpharma USA, Inc. · 1996K944964 · Branemark System Miruscone Abutment System · Nobelpharma USA, Inc. · 1995−50+5
  1. Root · 8 generations backK944964 Branemark System Miruscone Abutment SystemNobelpharma USA, Inc. · 1995
  2. 7 generations backK961728 Miruscone Abutment SystemNobelpharma USA, Inc. · 1996
  3. 6 generations backK962403 Noblepharma Wide AccessoriesNobelpharma USA, Inc. · 1996
  4. 5 generations backK971706 Tiadapt Abutment SystemNobel Biocare Uas, Inc. · 1997
  5. 4 generations backK974150 Procera Preparable Abutment SystemNobel Biocare Uas, Inc. · 1998 · Recalled
  6. 3 generations backK032263 3I Patient-Specific Dental Abutment and Overdenture BarImplant Innovations, Inc. · 2004 · Recalled
  7. 2 generations backK043042 Procera Implant Bridge, Models 15-1001, 15-1002, 15-1051, 15-1052Nobel Biocare AB · 2004
  8. 1 generation backK090069 Procera Implant Bridge OverdentureNobel Biocare AB · 2009
  9. This deviceK091904 Nobelprocera ZI AbutmentNobel Biocare AB · 2009
  10. Descendant · cites it directly · 25 of its ownK132125 A.B. Dental Devices Dental Implants SystemA.B. Dental Devices, Ltd. · 2014
  11. Descendant · 2 generations on · 14 of its ownK140440 Noris Medical Dental Implants SystemNoris Medical, Ltd. · 2014
  12. Descendant · cites it directly · 8 of its ownK132881 Z5CZ-Systems AG · 2014
  13. Descendant · 3 generations on · 7 of its ownK151909 Noris Medical Zygomatic Dental Implant SystemNoris Medical, Ltd. · 2016
  14. Descendant · 2 generations on · 4 of its ownK172668 W Zirconia ImplantsTav Medical, Ltd. · 2018

Showing 5 of 35 descendants. See all descendants

Descendants cleared per year

2014: 42016: 22017: 12018: 32019: 62020: 62021: 22022: 42023: 12024: 32025: 12026: 2
2014high 6 (2019) · low 0 (2015)2026

Most influential descendants

Showing 5 of 35 · See all
  • K132125A.B. Dental Devices Dental Implants SystemA.B. Dental Devices, Ltd. · 2014 · cites it directly25descendants
  • K140440Noris Medical Dental Implants SystemNoris Medical, Ltd. · 2014 · 2 generations on14descendants
  • K132881Z5CZ-Systems AG · 2014 · cites it directly8descendants
  • K151909Noris Medical Zygomatic Dental Implant SystemNoris Medical, Ltd. · 2016 · 3 generations on7descendants
  • K172668W Zirconia ImplantsTav Medical, Ltd. · 2018 · 2 generations on4descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K944964Branemark System Miruscone Abutment SystemNobelpharma USA, Inc.1995—
−7K961728Miruscone Abutment SystemNobelpharma USA, Inc.1996—
−6K962403Noblepharma Wide AccessoriesNobelpharma USA, Inc.1996—
−5K971706Tiadapt Abutment SystemNobel Biocare Uas, Inc.1997—
−4K974150Procera Preparable Abutment SystemNobel Biocare Uas, Inc.19982
−3K0322633I Patient-Specific Dental Abutment and Overdenture BarImplant Innovations, Inc.20041
−2K043042Procera Implant Bridge, Models 15-1001, 15-1002, 15-1051, 15-1052Nobel Biocare AB2004—
−1K090069Procera Implant Bridge OverdentureNobel Biocare AB2009—
0 (this device)K091904Nobelprocera ZI AbutmentNobel Biocare AB2009—
+1K132125A.B. Dental Devices Dental Implants SystemA.B. Dental Devices, Ltd.2014—
+2K140440Noris Medical Dental Implants SystemNoris Medical, Ltd.2014—
+1K132881Z5CZ-Systems AG2014—
+3K151909Noris Medical Zygomatic Dental Implant SystemNoris Medical, Ltd.2016—
+2K172668W Zirconia ImplantsTav Medical, Ltd.2018—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
198910
199020
199110
199390
199490
199560
199660
199720
199820
199940
200010
200140
200230
200320
200420

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201440
201620
201710
201830
201960
202060
202120
202240
202310
202430
202510
202620
FIG. 1 — Lineage of K091904, 1995–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NHA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NHA device

  1. #1 K222288 DESS Dental Smart Solutionsscore 30.7 · 19 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K042658Procera Abutment Branemark, Models 10-4001, 10-4004, 10-5001, 10-5004, 10-6001, 10-6004
Summary page 1
…Implant Abutment (21 CFR 872.3630) Trade or Proprietary or Model Name: NobelProcera Zi Abutment Legally Marketed Devices: Nobel Biocare — Procera® Abutment Branemark (K042658) Nobel Biocare — Procera® Implant Bridge Overdenture (K090064) Devica Description: Nobel Biocare's NobelProcera Zi Abutment is a…
Nobel Biocare Uas, Inc.2004—
*K090069Procera Implant Bridge Overdenture
Our OCR of the scanned summary read K090064, FDA’s number for Eminent Spine Interbody Fusion System (Eminent Spine). Corrected to the number one digit away whose FDA name carries the summary’s words for the device, “Nobel Biocare — Procera® Implant Bridge Overdenture”.
Nobel Biocare AB2009—

Also cleared against K042658: 9 other devices →

What descends from it? (35)

See all 35

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K132125A.B. Dental Devices Dental Implants SystemA.B. Dental Devices, Ltd.201425
K132881Z5CZ-Systems AG20148

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 4 companies; a new generation was cleared every 10 months on median.
  • 8 of the 63 ancestors have a recall of any class.
  • Of its descendants, K132125 (A.B. Dental Devices, Ltd., 2014) has gone furthest, with 25 descendants of its own.
  • 9 other devices also cite its predicate K042658.

How does its category compare?

All NHA devices

NHA Abutment, Implant, Dental, Endosseous: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · NHA

40in 2025

2007: 382008: 312009: 302010: 192011: 312012: 252013: 222014: 272015: 292016: 382017: 312018: 312019: 282020: 382021: 292022: 332023: 512024: 432025: 402026 (partial year): 23
2007high 51 (2023) · low 19 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NHA

147in 2025

2007: 91 days median2008: 90 days median2009: 95 days median2010: 162 days median2011: 130 days median2012: 171 days median2013: 184 days median2014: 160 days median2015: 151 days median2016: 202 days median2017: 188 days median2018: 200 days median2019: 160 days median2020: 153 days median2021: 211 days median2022: 142 days median2023: 147 days median2024: 158 days median2025: 147 days median2026 (partial year): 169 days median
2007high 211 (2021) · low 90 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NHA

1in 2025

2007: 12008: 22011: 52012: 12013: 12015: 12016: 362017: 22018: 12020: 72023: 32025: 12026 (partial year): 3
2007high 36 (2016) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · NHA

838in 2025

2007: 12008: 82009: 302010: 612011: 562012: 52013: 1432014: 1462015: 8582016: 3142017: 5772018: 5912019: 5302020: 4582021: 5462022: 4972023: 6182024: 6352025: 838
2007high 858 (2015) · low 1 (2007)2025

MAUDE reports naming product code NHA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007389111
2008319028
20093095030
201019162061
201131130556
20122517115
2013221841143
2014271600146
2015291511858
20163820236314
2017311882577
2018312001591
2019281600530
2020381537458
2021292110546
2022331420497
2023511473618
2024431580635
2025401471838
2026231693—

What is it indicated for?

The NobelProcera Zi Abutments are premanufactured prosthetic components directly connected to endosseous dental implants and are intended for use as an aid in prosthetic rehabilitation.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K091904: Nobelprocera ZI Abutment.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K091904

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026