510(k) Report

510(k) · Cleared

Cleared

Medacta Bipolar Head

K091967510(k) TraditionalCleared Mar 2, 2010244-day reviewClass II21 CFR 888.3390

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Medacta International S.A. · KWY Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented

Cleared on Mar 2, 2010 as substantially equivalent to K082468 (Omni Life Science, Inc., 2009) and 3 other predicates after a 244-day review. Its family tree reaches back 3 generations to 1995. 9 later devices descend from it.

Decided
Mar 2, 2010
Review
244 days
Class
Class II
Product code
KWY
Recalls
None
Predicates
4

Its longest line of descent runs back 3 generations to K953510 (1995). 5 ancestors in all. 9 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2005: 1 other ancestor2002: 1 other ancestor2014: 2 descendants cleared2025: 2 descendants cleared2020: 2 descendants cleared2015: 1 descendant cleared2026: 1 descendant cleared2021: 1 descendant clearedK953510 · Hip Joint Femoral (Hemi-Hip) Metal/Polymer Cemented or Uncemented Prosthesis · Encore Orthopedics, Inc. · 1995 · recalledK982447 · Plus Bipolar Prosthesis Cocrmo · Plus Orthopedics · 1998K082468 · Apex Hip System Bipolar Head, Model H3-822XX and H3-828YY, XX=OD in [MM] (38-43), YY=OD in [MM](44-60) · Omni Life Science, Inc. · 2009 · recalled1995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors 1 generation forward: 3 descendants2 generations forward: 5 descendants3 generations forward: 1 descendant K082468 · Apex Hip System Bipolar Head, Model H3-822XX and H3-828YY, XX=OD in [MM] (38-43), YY=OD in [MM](44-60) · Omni Life Science, Inc. · 2009 · recalledK982447 · Plus Bipolar Prosthesis Cocrmo · Plus Orthopedics · 1998K953510 · Hip Joint Femoral (Hemi-Hip) Metal/Polymer Cemented or Uncemented Prosthesis · Encore Orthopedics, Inc. · 1995 · recalled0
  1. Root · 3 generations backK953510 Hip Joint Femoral (Hemi-Hip) Metal/Polymer Cemented or Uncemented…Encore Orthopedics, Inc. · 1995 · Recalled
  2. 2 generations backK982447 Plus Bipolar Prosthesis CocrmoPlus Orthopedics · 1998
  3. 1 generation backK082468 Apex Hip System Bipolar Head, Model H3-822XX and H3-828YY, XX=OD in…Omni Life Science, Inc. · 2009 · Recalled
  4. This deviceK091967 Medacta Bipolar HeadMedacta International S.A. · 2010
  5. Descendant · cites it directly · 5 of its ownK133370 Remedy Hip Stem, Pegasus Hip Stem, Evolve Helios Hip Stem, Evolve…Signature Orthopaedics Pty Limited · 2014
  6. Descendant · cites it directly · 1 of its ownK241461 Mpact Constrained LinerMedacta International S.A. · 2025
  7. Descendant · 2 generations on · 1 of its ownK143184 Evolve UniPolar HeadSignature Orthopaedics Pty, Ltd. · 2015
  8. Descendant · 2 generations on · 0 of its ownK260173 M-Vizion Femoral Revision System ExtensionMedacta International S.A. · 2026
  9. Descendant · 2 generations on · 0 of its ownK243043 Origin™ Cemented Hip StemSignature Orthopaedics Pty, Ltd. · 2025

Showing 5 of 9 descendants. See all descendants

Descendants cleared per year

2014: 22015: 12020: 22021: 12025: 22026: 1
2014high 2 (2014) · low 0 (2016)2026

Most influential descendants

Showing 5 of 9 · See all
  • K133370Remedy Hip Stem, Pegasus Hip Stem, Evolve Helios Hip Stem, Evolve Masters Hip Stem…Signature Orthopaedics Pty Limited · 2014 · cites it directly5descendants
  • K241461Mpact Constrained LinerMedacta International S.A. · 2025 · cites it directly1descendant
  • K143184Evolve UniPolar HeadSignature Orthopaedics Pty, Ltd. · 2015 · 2 generations on1descendant
  • K260173M-Vizion Femoral Revision System ExtensionMedacta International S.A. · 2026 · 2 generations on0descendants
  • K243043Origin™ Cemented Hip StemSignature Orthopaedics Pty, Ltd. · 2025 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K953510Hip Joint Femoral (Hemi-Hip) Metal/Polymer Cemented or Uncemented ProsthesisEncore Orthopedics, Inc.199518
−2K982447Plus Bipolar Prosthesis CocrmoPlus Orthopedics1998—
−1K082468Apex Hip System Bipolar Head, Model H3-822XX and H3-828YY, XX=OD in [MM]…Omni Life Science, Inc.200923
0 (this device)K091967Medacta Bipolar HeadMedacta International S.A.2010—
+1K133370Remedy Hip Stem, Pegasus Hip Stem, Evolve Helios Hip Stem, Evolve Masters Hip…Signature Orthopaedics Pty Limited2014—
+1K241461Mpact Constrained LinerMedacta International S.A.2025—
+2K143184Evolve UniPolar HeadSignature Orthopaedics Pty, Ltd.2015—
+2K260173M-Vizion Femoral Revision System ExtensionMedacta International S.A.2026—
+2K243043Origin™ Cemented Hip StemSignature Orthopaedics Pty, Ltd.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200210
200510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201420
201510
202020
202110
202520
202610
FIG. 1 — Lineage of K091967, 1995–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KWY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KWY device

  1. #1 K253357 b-ONE® Bipolar Headscore 11.2 · 1 generation · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K082468Apex Hip System Bipolar Head, Model H3-822XX and H3-828YY, XX=OD in [MM] (38-43), YY=OD…
Summary page 1
…is 21 CFR 888.3390 Class 11 Device Product Code: KW~Y Predicate Devices: K082468 Apex Hip System Bipolar Head K050966 Ortho Development Pivot Bipolar Head…
Omni Life Science, Inc.200923
*K050966Pivot Bipolar Femoral Head
Summary page 1
…Class 11 Device Product Code: KW~Y Predicate Devices: K082468 Apex Hip System Bipolar Head K050966 Ortho Development Pivot Bipolar Head K014072 Disc-O-Tech Medical Technologies Ltd's…
Ortho Development Corp.20052
*K014072Fixion Unipolar Modular Hemi-Hip System (Fixion UH)
Summary page 1
…Predicate Devices: K082468 Apex Hip System Bipolar Head K050966 Ortho Development Pivot Bipolar Head K014072 Disc-O-Tech Medical Technologies Ltd's Fixion TM Unipolar Modular Hemi-Hip System…
Disc-O-Tech Medical Technologies, Ltd.2002—
*K982447Plus Bipolar Prosthesis Cocrmo
Summary page 1
…K014072 Disc-O-Tech Medical Technologies Ltd's Fixion TM Unipolar Modular Hemi-Hip System K982447 Plus Orthopedics PLUS Bipolar Heads Medacta Bipolar Heads 510(k) Section 5 -Page 2 of 4 === Pag…
Plus Orthopedics1998—

Also cleared against K082468: 5 other devices →

What descends from it? (9)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K133370Remedy Hip Stem, Pegasus Hip Stem, Evolve Helios Hip Stem, Evolve Masters Hip Stem…Signature Orthopaedics Pty Limited20145
K241461Mpact Constrained LinerMedacta International S.A.20251
K132539Ring-Lok Modular Bipolar SystemImplants International, Ltd.20140

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 15 years and passes through 4 companies; a new generation was cleared every 3.3 years on median.
  • 3 of the 5 ancestors have a recall of any class.
  • Of its descendants, K133370 (Signature Orthopaedics Pty Limited, 2014) has gone furthest, with 5 descendants of its own.
  • 5 other devices also cite its predicate K082468.

How does its category compare?

All KWY devices

KWY Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · KWY

1in 2025

2008: 32009: 12010: 42011: 12012: 12013: 22014: 12015: 12016: 12017: 12018: 32019: 52020: 12022: 22023: 22025: 12026 (partial year): 1
2007high 5 (2019) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KWY

126in 2019

2008: 123 days median2010: 187 days median2018: 219 days median2019: 126 days median
2007high 219 (2018) · low 123 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KWY

2in 2025

2007: 252009: 242010: 12012: 12013: 22016: 32017: 22018: 12019: 12024: 12025: 2
2007high 25 (2007) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KWY

180in 2025

2007: 3702008: 9002009: 9612010: 6882011: 7582012: 9782013: 1,1482014: 1,0552015: 1,2132016: 8772017: 8262018: 1,3802019: 1,5302020: 1,2592021: 2762022: 2082023: 1782024: 2092025: 180
2007high 1,530 (2019) · low 178 (2023)2025

MAUDE reports naming product code KWY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—25370
200831230900
20091—24961
201041871688
20111—0758
20121—1978
20132—21,148
20141—01,055
20151—01,213
20161—3877
20171—2826
2018321911,380
2019512611,530
20201—01,259
20210—0276
20222—0208
20232—0178
20240—1209
20251—2180
20261—0—

What is it indicated for?

The Medacta® Bipolar Head is intended for use in combination with Medacta® Hip Prosthesis System and Mectacer femoral heads for uncemented primary or revision hemniarthroplasty of the hip. This prosthesis may be used for the following conditions, as appropriate:

* Femoral neck and trochanteric fractures of the proximal femur;

* Osteonecrosis of the femoral head;

* Revision procedures where other devices or treatments for these indications have failed,

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K091967: Medacta Bipolar Head.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K091967

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026