PC Ecg, Model SE-1010

K092010510(k) TraditionalCleared Oct 22, 2009108-day reviewClass II21 CFR 870.2340

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Edan Instruments, Inc. · DPS Electrocardiograph

Cleared on Oct 22, 2009 as substantially equivalent to K031561 (Ge Medical Systems Information Technologies, 2003) after a 108-day review. Its family tree reaches back 5 generations to 1991. 18 later devices descend from it.

Decided
Oct 22, 2009
Review
108 days
Class
Class II
Product code
DPS
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K903644 (1991). 8 ancestors in all. 18 later devices descend from it, 5 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2000: 1 other ancestor1996: 2 other ancestors2015: 2 descendants cleared2014: 1 descendant cleared2010: 2 descendants cleared2013: 1 descendant cleared2017: 2 descendants cleared2016: 2 descendants cleared2018: 1 descendant cleared2022: 2 descendants cleared2021: 1 descendant cleared2020: 1 descendant cleared2026: 1 descendant cleared2023: 1 descendant cleared2024: 1 descendant clearedK903644 · Series 1500 12-Lead Analysis Option · Marquette Electronics, Inc. · 1991K973403 · Cardiosmart ST · Marquette Medical Systems, Inc. · 1998K991014 · Case 8000 Exercise Testing System · General Electric Medical Systems Information Techn · 1999K023380 · T-Wave Altermans (Twa) Algorithm Option · General Electric Medical Systems Information Techn · 2002K031561 · Cardiosoft/Case Cardiac Testing System · Ge Medical Systems Information Technologies · 20031990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 2 other ancestors4 generations back: 1 other ancestor 1 generation forward: 5 descendants2 generations forward: 2 descendants3 generations forward: 3 descendants4 generations forward: 4 descendants5 generations forward: 3 descendants6 generations forward: 1 descendant K031561 · Cardiosoft/Case Cardiac Testing System · Ge Medical Systems Information Technologies · 2003K023380 · T-Wave Altermans (Twa) Algorithm Option · General Electric Medical Systems Information Techn · 2002K991014 · Case 8000 Exercise Testing System · General Electric Medical Systems Information Techn · 1999K973403 · Cardiosmart ST · Marquette Medical Systems, Inc. · 1998K903644 · Series 1500 12-Lead Analysis Option · Marquette Electronics, Inc. · 1991−50+5
  1. Root · 5 generations backK903644 Series 1500 12-Lead Analysis OptionMarquette Electronics, Inc. · 1991
  2. 4 generations backK973403 Cardiosmart STMarquette Medical Systems, Inc. · 1998
  3. 3 generations backK991014 Case 8000 Exercise Testing SystemGeneral Electric Medical Systems Information Techn · 1999
  4. 2 generations backK023380 T-Wave Altermans (Twa) Algorithm OptionGeneral Electric Medical Systems Information Techn · 2002
  5. 1 generation backK031561 Cardiosoft/Case Cardiac Testing SystemGe Medical Systems Information Technologies · 2003
  6. This deviceK092010 PC Ecg, Model SE-1010Edan Instruments, Inc. · 2009
  7. Descendant · cites it directly · 13 of its ownK102854 PC ECGEdan Instruments, Inc. · 2010
  8. Descendant · 2 generations on · 12 of its ownK131819 PC ECGEdan Instruments, Inc. · 2013
  9. Descendant · 3 generations on · 11 of its ownK152427 PC ECGEdan Instruments, Inc. · 2016
  10. Descendant · cites it directly · 10 of its ownK093869 SE-601 Series ElectrocardiographEdan Instruments, Inc. · 2010
  11. Descendant · cites it directly · 9 of its ownK131503 SE-601 Series ElectrocardiographEdan Instruments, Inc. · 2014

Showing 5 of 18 descendants. See all descendants

Descendants cleared per year

2010: 22013: 12014: 12015: 22016: 22017: 22018: 12020: 12021: 12022: 22023: 12024: 12026: 1
2010high 2 (2010) · low 0 (2011)2026

Most influential descendants

Showing 5 of 18 · See all
  • K102854PC ECGEdan Instruments, Inc. · 2010 · cites it directly13descendants
  • K131819PC ECGEdan Instruments, Inc. · 2013 · 2 generations on12descendants
  • K152427PC ECGEdan Instruments, Inc. · 2016 · 3 generations on11descendants
  • K093869SE-601 Series ElectrocardiographEdan Instruments, Inc. · 2010 · cites it directly10descendants
  • K131503SE-601 Series ElectrocardiographEdan Instruments, Inc. · 2014 · cites it directly9descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K903644Series 1500 12-Lead Analysis OptionMarquette Electronics, Inc.1991—
−4K973403Cardiosmart STMarquette Medical Systems, Inc.1998—
−3K991014Case 8000 Exercise Testing SystemGeneral Electric Medical Systems Information Techn1999—
−2K023380T-Wave Altermans (Twa) Algorithm OptionGeneral Electric Medical Systems Information Techn2002—
−1K031561Cardiosoft/Case Cardiac Testing SystemGe Medical Systems Information Technologies2003—
0 (this device)K092010PC Ecg, Model SE-1010Edan Instruments, Inc.2009—
+1K102854PC ECGEdan Instruments, Inc.2010—
+2K131819PC ECGEdan Instruments, Inc.2013—
+3K152427PC ECGEdan Instruments, Inc.2016—
+1K093869SE-601 Series ElectrocardiographEdan Instruments, Inc.2010—
+1K131503SE-601 Series ElectrocardiographEdan Instruments, Inc.2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199620
200010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201020
201310
201410
201520
201620
201720
201810
202010
202110
202220
202310
202410
202610
FIG. 1 — Lineage of K092010, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DPS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DPS device

  1. #1 K212112 Cardiologs Holter Platformscore 18.6 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K031561Cardiosoft/Case Cardiac Testing System
Summary page 1
…ification Name: 21 CFR 870.2340 Electrocardiograph Product code: DPS Predicate Devices: Cardiosoft/case cardiac testing system K031561 Manufacturer: GE medical.systems information technologies Device Description: PC ECG inclu…
Ge Medical Systems Information Technologies2003—

Also cleared against K031561: 5 other devices →

What descends from it? (18)

See all 18

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K102854PC ECGEdan Instruments, Inc.201013
K093869SE-601 Series ElectrocardiographEdan Instruments, Inc.201010
K131503SE-601 Series ElectrocardiographEdan Instruments, Inc.20149
K133985Digital ElectrocardiographShenzhen Biocare Bio-Medical Equipment Co., Ltd.20151
K152384Digital ElectrocardiographShenzhen Biocare Bio-Medical Equipment Co., Ltd.20150

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 5 companies; a new generation was cleared every 3.1 years on median.
  • None of the 8 ancestors has a recall.
  • Of its descendants, K102854 (Edan Instruments, Inc., 2010) has gone furthest, with 13 descendants of its own.
  • 5 other devices also cite its predicate K031561.

How does its category compare?

All DPS devices

DPS Electrocardiograph: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · DPS

6in 2025

2007: 112008: 132009: 142010: 112011: 222012: 122013: 102014: 112015: 82016: 112017: 92018: 142019: 32020: 62021: 52022: 62023: 102024: 82025: 62026 (partial year): 6
2007high 22 (2011) · low 3 (2019)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DPS

163in 2025

2007: 87 days median2008: 31 days median2009: 84 days median2010: 104 days median2011: 154 days median2012: 117 days median2013: 134 days median2014: 253 days median2015: 178 days median2016: 229 days median2017: 177 days median2018: 221 days median2019: 178 days median2020: 224 days median2021: 135 days median2022: 244 days median2023: 236 days median2024: 260 days median2025: 163 days median2026 (partial year): 258 days median
2007high 260 (2024) · low 31 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DPS

3in 2025

2007: 22009: 12010: 22011: 12019: 92020: 22021: 12022: 12023: 32024: 4, 1 Class I2025: 32026 (partial year): 4
2007high 9 (2019) · low 0 (2008)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · DPS

55in 2025

2007: 92008: 172009: 142010: 212011: 1212012: 562013: 152014: 152015: 302016: 122017: 152018: 192019: 272020: 592021: 242022: 592023: 542024: 642025: 55
2007high 121 (2011) · low 9 (2007)2025

MAUDE reports naming product code DPS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007118729
20081331017
20091484114
201011104221
2011221541121
201212117056
201310134015
201411253015
20158178030
201611229012
20179177015
201814221019
20193178927
20206224259
20215135124
20226244159
202310236354
202482604 (1)64
20256163355
202662584—

What is it indicated for?

SE-I010 PC ECG is intended to acquire ECG signals, from adult and pediatric patients through body surface ECG electrodes. SE-1010 PC ECG is only intended to be used in hospitals or healthcare facilities by doctors and trained healthcare professionals. The cardiogram recorded by SE-I010 PC ECG can help users to analyze and diagnose heart disease. However the ECG with measurements and interpretive statements is offered to clinician on an advisory basis only.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K092010: PC Ecg, Model SE-1010.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K092010

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026