510(k) Report

510(k) · Cleared

Cleared

Med-Seg, Model BTMS 1000

K092328510(k) AbbreviatedCleared Jul 26, 2010356-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bartron Medical Imaging, Inc. · LLZ System, Image Processing, Radiological

Cleared on Jul 26, 2010 as substantially equivalent to K090481 (Demasq Limited, 2009) after a 356-day review. Its family tree reaches back 7 generations to 1990.

Decided
Jul 26, 2010
Review
356 days
Class
Class II
Product code
LLZ
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K896095 (1990). 16 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 7 generations backK896095 Images-on-Call Teleradiology SystemDevices & Services Co. · 1990
  2. 6 generations backK962699 Radworks Medical Imaging SoftwareApplicare Medical Imaging, B.V. · 1996
  3. 5 generations backK982862 Radworks Medical Imaging Software with Quality Control ModuleApplicare Medical Imaging, B.V. · 1998
  4. 4 generations backK012211 Efilm WorkstationEfilm Medical, Inc. · 2001 · Recalled
  5. 3 generations backK023476 Unipacs WorkstationUniversal Pacs, Inc. · 2003
  6. 2 generations backK071894 Xebra Dicom Image BrowserHx Technologies, Inc. · 2007
  7. 1 generation backK090481 Demasq Imaging Spftware DeviceDemasq Limited · 2009
  8. This deviceK092328 Med-Seg, Model BTMS 1000Bartron Medical Imaging, Inc. · 2010
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K896095Images-on-Call Teleradiology SystemDevices & Services Co.1990—
−6K962699Radworks Medical Imaging SoftwareApplicare Medical Imaging, B.V.1996—
−5K982862Radworks Medical Imaging Software with Quality Control ModuleApplicare Medical Imaging, B.V.1998—
−4K012211Efilm WorkstationEfilm Medical, Inc.20011
−3K023476Unipacs WorkstationUniversal Pacs, Inc.2003—
−2K071894Xebra Dicom Image BrowserHx Technologies, Inc.2007—
−1K090481Demasq Imaging Spftware DeviceDemasq Limited2009—
0 (this device)K092328Med-Seg, Model BTMS 1000Bartron Medical Imaging, Inc.2010—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199410
199610
200110
200320
200420
200510
FIG. 1 — Lineage of K092328, 1990–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K090481Demasq Imaging Spftware Device
Summary page 2
…7e A GOOD IMAGE IS WORTH A THOUSAND WORDS Predicate Device DEMASQ Imaging Software, manufactured by DEMASQ Ltd of Wales, United Kingdom and cleared under 510(k) #K090481 on March 19, 2009. Intended Use I Indications for Use MED-SEG is a software device that receives medical images and data from v…
Demasq Limited2009—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 20 years and passes through 7 companies; a new generation was cleared every 2.2 years on median.
  • 1 of the 16 ancestors has a recall of any class.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

MED-SEG is a software device that receives medical images and data from various imaging sources (including but not limited to CT, MR, US, RF units), computed and direct radiographic devices, and secondary capture devices, (scanners, imaging gateways or imaging sources). Images and data can be stored, communicated, processed and displayed within the system or across computer networks at distributed locations. In addition to general PACS use, this system…

Read the full statement (158 words)

MED-SEG is a software device that receives medical images and data from various imaging sources (including but not limited to CT, MR, US, RF units), computed and direct radiographic devices, and secondary capture devices, (scanners, imaging gateways or imaging sources). Images and data can be stored, communicated, processed and displayed within the system or across computer networks at distributed locations.

In addition to general PACS use, this system can be used by trained professionals (e.g. physicians, radiologists, nurses, medical technicians, and assistants) to separate 2D images into "digitally related" sections or regions that, after colorization, can be individually labeled by the user. These images can be used to find appropriate window/level settings, to facilitate report generation and communication, or for other uses. These processed images should not be used for primary image diagnosis.

Only DICOM "for presentation" uncompressed or non-lossy compressed images can be used on an FDA cleared or approved monitor for primary image diagnosis in mammography.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K092328: Med-Seg, Model BTMS 1000.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K092328

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026