510(k) Report

510(k) · Cleared

Cleared

Hydro-Guard Mini Breathing Filter and Heat and Moisture Exchanger and Air-Guard Clear Breathing Filter

K092409510(k) TraditionalCleared Mar 10, 2010216-day reviewClass II21 CFR 868.5260

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Intersurgical, Inc. · CAH Filter, Bacterial, Breathing-Circuit

Cleared on Mar 10, 2010 after a 216-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 1 later device descends from it.

Decided
Mar 10, 2010
Review
216 days
Class
Class II
Product code
CAH
Recalls
None
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2021: 1 descendant cleared2010201520202025
  1. This deviceK092409 Hydro-Guard Mini Breathing Filter and Heat and Moisture Exchanger…Intersurgical, Inc. · 2010
  2. Descendant · cites it directly · 0 of its ownK211286 Ultipor U55/U55N Breathing Circuit Filter and Heat and Moisture…Pall Corporation · 2021

Most influential descendants

Showing 1 of 1 · See all
  • K211286Ultipor U55/U55N Breathing Circuit Filter and Heat and Moisture ExchangerPall Corporation · 2021 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K092409Hydro-Guard Mini Breathing Filter and Heat and Moisture Exchanger and…Intersurgical, Inc.2010—
+1K211286Ultipor U55/U55N Breathing Circuit Filter and Heat and Moisture ExchangerPall Corporation2021—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202110
FIG. 1 — Lineage of K092409, 2010–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CAH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CAH device

  1. #1 K251583 Ambu® Virobac II® Exhalation Filterscore 11.6 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K211286Ultipor U55/U55N Breathing Circuit Filter and Heat and Moisture ExchangerPall Corporation20210

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K211286 (Pall Corporation, 2021) has gone furthest, with 0 descendants of its own.

How does its category compare?

All CAH devices

CAH Filter, Bacterial, Breathing-Circuit: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · CAH

2in 2024

2007: 22008: 12009: 42010: 52011: 32012: 32013: 12014: 42015: 22017: 12019: 22020: 22021: 22022: 32023: 32024: 22026 (partial year): 2
2007high 5 (2010) · low 0 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CAH

237in 2023

2009: 111 days median2010: 216 days median2011: 281 days median2012: 212 days median2014: 250 days median2022: 204 days median2023: 237 days median
2007high 281 (2011) · low 111 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CAH

1in 2025

2010: 22013: 12014: 12017: 12022: 6, 6 Class I2025: 1, 1 Class I
2007high 6 (2022) · low 0 (2007)2026

Class I (7 since 2007) Class II/III not classified

Adverse event reports per year · CAH

77in 2025

2007: 322008: 272009: 182010: 402011: 92012: 162013: 472014: 982015: 512016: 342017: 292018: 332019: 302020: 332021: 562022: 672023: 402024: 512025: 77
2007high 98 (2014) · low 9 (2011)2025

MAUDE reports naming product code CAH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—032
20081—027
20094111018
20105216240
2011328109
20123212016
20131—147
20144250198
20152—051
20160—034
20171—129
20180—033
20192—030
20202—033
20212—056
202232046 (6)67
20233237040
20242—051
20250—1 (1)77
20262—0—

What is it indicated for?

The Intersurgical Hydro-Guard. Mini Filter and Heat and Moisture Exchanger is for use at the patient and equipment connections. It is designed to reduce bacterial/viral transmissions between the patient and equipment and to reduce the loss of patient heat and humidity. The Intersurgical Air-Guard Breathing Filter is for use at the equipment connections. It is designed to reduce bacterial/viral transmissions in order to protect oxygen concentrator…

Read the full statement (105 words)

The Intersurgical Hydro-Guard. Mini Filter and Heat and Moisture Exchanger is for use at the patient and equipment connections. It is designed to reduce bacterial/viral transmissions between the patient and equipment and to reduce the loss of patient heat and humidity.

The Intersurgical Air-Guard Breathing Filter is for use at the equipment connections. It is designed to reduce bacterial/viral transmissions in order to protect oxygen concentrator machines and respiratory equipment.

Both filters are single patient use for an adult target patient population, are intended for use within breathing systems in healthcare and home environments where ventilation is required and a maximum duration of 24 hours.

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K092409: Hydro-Guard Mini Breathing Filter and Heat and Moisture Exchanger and Air-Guard Clear Breathing Filter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K092409

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026