510(k) Report

510(k) · Cleared

Cleared

Nomad Sleep System Recorder, Model PMU800

K092699510(k) TraditionalCleared Mar 18, 2010197-day reviewClass II21 CFR 882.1835

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Neurotronics, Inc. · GWL Amplifier, Physiological Signal

Cleared on Mar 18, 2010 after a 197-day review. The FDA summary names its predicate without a number. 3 later devices descend from it.

Decided
Mar 18, 2010
Review
197 days
Class
Class II
Product code
GWL
Recalls
None
Predicates
0

3 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2022: 1 descendant cleared2024: 1 descendant cleared2023: 1 descendant cleared2010201520202025
  1. This deviceK092699 Nomad Sleep System Recorder, Model PMU800Neurotronics, Inc. · 2010
  2. Descendant · cites it directly · 1 of its ownK220631 NomadAir PMU810Neurotronics, Inc. · 2022
  3. Descendant · cites it directly · 0 of its ownK240646 DreamClearSomnomed Technologies Inc., Doing Business AS Remware · 2024
  4. Descendant · 2 generations on · 0 of its ownK223676 SomniCheckBrainmatterz, LLC · 2023

Most influential descendants

Showing 3 of 3 · See all
  • K220631NomadAir PMU810Neurotronics, Inc. · 2022 · cites it directly1descendant
  • K240646DreamClearSomnomed Technologies Inc., Doing Business AS Remware · 2024 · cites it directly0descendants
  • K223676SomniCheckBrainmatterz, LLC · 2023 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K092699Nomad Sleep System Recorder, Model PMU800Neurotronics, Inc.2010—
+1K220631NomadAir PMU810Neurotronics, Inc.2022—
+1K240646DreamClearSomnomed Technologies Inc., Doing Business AS Remware2024—
+2K223676SomniCheckBrainmatterz, LLC2023—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202210
202310
202410
FIG. 1 — Lineage of K092699, 2010–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GWL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GWL device

  1. #1 K232210 X-trodes System Mscore 10.4 · 13 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Neurotronics Sphinx
Named without a submission number
—

What descends from it? (3)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K220631NomadAir PMU810Neurotronics, Inc.20221
K240646DreamClearSomnomed Technologies Inc., Doing Business AS Remware20240

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K220631 (Neurotronics, Inc., 2022) has gone furthest, with 1 descendant of its own.

How does its category compare?

All GWL devices

GWL Amplifier, Physiological Signal: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · GWL

1in 2025

2007: 12009: 22010: 12011: 12012: 22014: 12015: 12017: 22018: 12020: 12021: 22022: 12023: 22024: 42025: 1
2007high 4 (2024) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GWL

133in 2024

2024: 133 days median
2007high 133 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GWL

1in 2013

2010: 12013: 1
2007high 1 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GWL

1in 2018

2008: 22018: 1
2007high 2 (2008) · low 0 (2007)2025

MAUDE reports naming product code GWL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20080—02
20092—00
20101—10
20111—00
20122—00
20130—10
20141—00
20151—00
20160—00
20172—00
20181—01
20190—00
20201—00
20212—00
20221—00
20232—00
2024413300
20251—00
20260—0—

What is it indicated for?

The Nomad device is a digital amplifier capable of measuring bio-potential signals that may be incorporated into a Polysomnogram. The device is intended to measure, amplify, and record physiological signals acquired from a patient for archival in a Sleep Study, such as Limb Movement, Respiration Effort, and SpO2. The data may be analyzed on dedicated polysomnography software running on a personal computer by a qualified sleep clinician to aid in the…

Read the full statement (161 words)

The Nomad device is a digital amplifier capable of measuring bio-potential signals that may be incorporated into a Polysomnogram.

The device is intended to measure, amplify, and record physiological signals acquired from a patient for archival in a Sleep Study, such as Limb Movement, Respiration Effort, and SpO2. The data may be analyzed on dedicated polysomnography software running on a personal computer by a qualified sleep clinician to aid in the diagnosis of Sleep Disorders.

This device is not to be used alone as an apnea monitor or as a critical component in an apnea monitoring system.

This device is intended for use on both adults and children on the order of physician.

This device, or any accessory, is not to be used alone as a life support device or as a critical component of a life support system.

The device is not sterile.

Caution: Federal (USA) law restricts this device to sale by or on the order of a physician.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K092699: Nomad Sleep System Recorder, Model PMU800.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K092699

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026