510(k) · Cleared
ClearedMicroendoscope Model S-0001 Single Light Source, Microendoscope, Model D-0001 Dual Light Source Sterile
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
C-Link Micro Imaging, Inc. · ODF Mini Endoscope, Gastroenterology-Urology
Cleared on Jan 12, 2010 as substantially equivalent to K011189 (Acueity, Inc., 2001) after a 126-day review. Its family tree reaches back 1 generation to 2001.
- Decided
- Jan 12, 2010
- Review
- 126 days
- Class
- Class II
- Product code
- ODF
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K011189 (2001). No later device cites it as a predicate yet.
- Root · 1 generation backK011189 Viaduct Microendoscope and AccessoriesAcueity, Inc. · 2001
- This deviceK092739 Microendoscope Model S-0001 Single Light Source, Microendoscope…C-Link Micro Imaging, Inc. · 2010
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K011189 | Viaduct Microendoscope and Accessories | Acueity, Inc. | 2001 | — |
| 0 (this device) | K092739 | Microendoscope Model S-0001 Single Light Source, Microendoscope, Model D-0001… | C-Link Micro Imaging, Inc. | 2010 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in ODF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K011189 | Viaduct Microendoscope and Accessories | 2001 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Its one ancestor has no recall.
- 5 other devices also cite its predicate K011189.
How does its category compare?
All ODF devicesODF Mini Endoscope, Gastroenterology-Urology: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.
FDA decisions per year · ODF
1in 2010
2026 to Oct 25, outlined.
Median 510(k) review, days · ODF
Too few ODF 510(k)s in any year since 2007 to give a median.
Recalls per year · ODF
No recall names ODF since 2007.
Adverse event reports per year · ODF
1in 2022
MAUDE reports naming product code ODF, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 5 |
| 2009 | 2 | — | 0 | 4 |
| 2010 | 1 | — | 0 | 1 |
| 2011 | 0 | — | 0 | 5 |
| 2012 | 0 | — | 0 | 4 |
| 2013 | 0 | — | 0 | 3 |
| 2014 | 0 | — | 0 | 2 |
| 2015 | 0 | — | 0 | 1 |
| 2016 | 0 | — | 0 | 1 |
| 2017 | 0 | — | 0 | 1 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 1 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 0 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
This device is to be used by a physician for viewing an interior cavity of the human body through either a natural opening or an incision.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K092739 · printed Nov 5, 2026
Cite this page
510(k) Report. “K092739: Microendoscope Model S-0001 Single Light Source, Microendoscope, Model D-0001 Dual Light Source Sterile.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K092739
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026