510(k) · Cleared
ClearedMasimo Set Rad 8 Pulse Oximeter and Accessories, Model Rad 8
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Masimo Corporation · DQA Oximeter
Cleared on Oct 15, 2009 as substantially equivalent to K053269 (Masimo Corporation, 2005) after a 30-day review. Its family tree reaches back 4 generations to 2000. 38 later devices descend from it.
- Decided
- Oct 15, 2009
- Review
- 30 days
- Class
- Class II
- Product code
- DQA
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 4 generations to K000126 (2000). 38 later devices descend from it, 1 citing it directly.
- Root · 4 generations backK000126 Masimo Set Radical Pulse Oximeter with Satshare, Masimo…Masimo Corp. · 2000
- 3 generations backK031330 Modification to Masimo Set Radical Pulse Oximeter with Satshare and…Masimo Corp. · 2003
- 2 generations backK033296 Masimo Set Rad-5 Pulse Oximeter, Model Rad-5; Masimo Set Rad-5V…Masimo Corp. · 2004 · Recalled
- 1 generation backK053269 Masimo Set Rad-8 Pulse OximeterMasimo Corporation · 2005
- This deviceK092838 Masimo Set Rad 8 Pulse Oximeter and Accessories, Model Rad 8Masimo Corporation · 2009
- Descendant · cites it directly · 37 of its ownK120657 Masimo Set and Masimo Rainbow Set Pulse Oximeters and SensorsMasimo Corporation · 2012
- Descendant · 2 generations on · 34 of its ownK150975 Philips IntelliVue MP2/MP5/MPSC Patient Monitors, Philips IntelliVue…Philips Medizin Systeme Boeblingen GmbH · 2015 · Recalled
- Descendant · 3 generations on · 31 of its ownK161531 IntelliVue Patient Monitors MP2, MP5, MP5T, MP5SC, and…Philips Medizin Systeme Boeblingen GmbH · 2016 · Recalled
- Descendant · 4 generations on · 8 of its ownK171801 IntelliVue Patient Monitor MX100 and Multi-Measurement Module X3…Philips Medizin Systeme Boeblingen GmbH · 2017 · Recalled
- Descendant · 4 generations on · 6 of its ownK221704 HemoSphere Advanced Monitor, Right Ventricular Pressure (RVP)…Edwards Lifesciences, LLC · 2022
Showing 5 of 38 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 38 · See all- K120657Masimo Set and Masimo Rainbow Set Pulse Oximeters and SensorsMasimo Corporation · 2012 · cites it directly37descendants
- K150975Philips IntelliVue MP2/MP5/MPSC Patient Monitors, Philips IntelliVue X1 and X2…Philips Medizin Systeme Boeblingen GmbH · 2015 · 2 generations on34descendants
- K161531IntelliVue Patient Monitors MP2, MP5, MP5T, MP5SC, and Multi-Measurement Module X2…Philips Medizin Systeme Boeblingen GmbH · 2016 · 3 generations on31descendants
- K171801IntelliVue Patient Monitor MX100 and Multi-Measurement Module X3; intelliVue Hemodynamic…Philips Medizin Systeme Boeblingen GmbH · 2017 · 4 generations on8descendants
- K221704HemoSphere Advanced Monitor, Right Ventricular Pressure (RVP), Global Hypoperfusion…Edwards Lifesciences, LLC · 2022 · 4 generations on6descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K000126 | Masimo Set Radical Pulse Oximeter with Satshare, Masimo… | Masimo Corp. | 2000 | — |
| −3 | K031330 | Modification to Masimo Set Radical Pulse Oximeter with Satshare and Lnop… | Masimo Corp. | 2003 | — |
| −2 | K033296 | Masimo Set Rad-5 Pulse Oximeter, Model Rad-5; Masimo Set Rad-5V Pulse… | Masimo Corp. | 2004 | 1 |
| −1 | K053269 | Masimo Set Rad-8 Pulse Oximeter | Masimo Corporation | 2005 | — |
| 0 (this device) | K092838 | Masimo Set Rad 8 Pulse Oximeter and Accessories, Model Rad 8 | Masimo Corporation | 2009 | — |
| +1 | K120657 | Masimo Set and Masimo Rainbow Set Pulse Oximeters and Sensors | Masimo Corporation | 2012 | — |
| +2 | K150975 | Philips IntelliVue MP2/MP5/MPSC Patient Monitors, Philips IntelliVue X1 and X2… | Philips Medizin Systeme Boeblingen GmbH | 2015 | 1 |
| +3 | K161531 | IntelliVue Patient Monitors MP2, MP5, MP5T, MP5SC, and Multi-Measurement… | Philips Medizin Systeme Boeblingen GmbH | 2016 | 1 |
| +4 | K171801 | IntelliVue Patient Monitor MX100 and Multi-Measurement Module X3; intelliVue… | Philips Medizin Systeme Boeblingen GmbH | 2017 | 4 |
| +4 | K221704 | HemoSphere Advanced Monitor, Right Ventricular Pressure (RVP), Global… | Edwards Lifesciences, LLC | 2022 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2012 | 1 | 0 |
| 2014 | 1 | 0 |
| 2015 | 2 | 0 |
| 2016 | 2 | 0 |
| 2017 | 2 | 0 |
| 2018 | 4 | 0 |
| 2019 | 4 | 0 |
| 2020 | 1 | 0 |
| 2021 | 1 | 0 |
| 2022 | 3 | 0 |
| 2023 | 6 | 0 |
| 2024 | 1 | 0 |
| 2025 | 6 | 0 |
| 2026 | 4 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DQA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DQA device
- #1 K221282 Empatica Health Monitoring Platformscore 20.1 · 38 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K053269 | Masimo Set Rad-8 Pulse OximeterSummary page 1…Oximeter (74DQA) (870.2700) Substantially Equivalent Devices Masimo SET® Rad 8 Pulse Oximeter 510(k) Number- K053269 Device Description The Masimo SET® Rad-8 Pulse Oximeter and Accessories (Rad 8) have the following features and benefits:… | 2005 |
What descends from it? (38)
See all 381 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K120657 | Masimo Set and Masimo Rainbow Set Pulse Oximeters and Sensors | 2012 | 37 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 9 years and passes through 2 companies; a new generation was cleared every 3.1 years on median.
- 1 of the 4 ancestors has a recall of any class.
- Of its descendants, K120657 (Masimo Corporation, 2012) has gone furthest, with 37 descendants of its own.
- 4 other devices also cite its predicate K053269.
How does its category compare?
All DQA devicesDQA Oximeter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.
FDA decisions per year · DQA
15in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DQA
182in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DQA
3in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DQA
399in 2025
MAUDE reports naming product code DQA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 20 | 122 | 6 | 325 |
| 2008 | 22 | 97 | 5 | 312 |
| 2009 | 35 | 117 | 29 | 281 |
| 2010 | 29 | 127 | 4 | 185 |
| 2011 | 15 | 195 | 1 | 164 |
| 2012 | 14 | 120 | 0 | 322 |
| 2013 | 15 | 182 | 0 | 468 |
| 2014 | 11 | 175 | 2 | 1,124 |
| 2015 | 13 | 158 | 1 | 2,082 |
| 2016 | 14 | 246 | 0 | 1,775 |
| 2017 | 9 | 200 | 0 | 1,190 |
| 2018 | 18 | 260 | 32 | 694 |
| 2019 | 19 | 158 | 0 | 548 |
| 2020 | 15 | 126 | 0 | 426 |
| 2021 | 10 | 174 | 0 | 553 |
| 2022 | 20 | 265 | 0 | 478 |
| 2023 | 13 | 317 | 0 | 392 |
| 2024 | 14 | 285 | 3 | 545 |
| 2025 | 15 | 182 | 0 | 399 |
| 2026 | 8 | 187 | 0 | — |
What is it indicated for?
The Masimo SET® Rad-8 Pulse Oximeter and Accessories are indicated for the continuous noninvasive monitoring of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate (measured by an SPO2 sensor). The Masimo SET® Rad-8 Pulse Oximeter and Accessories are indicated for use with adult, pediatric, and neonatal patients during both no motion and motion conditions, for patients who are well or poorly perfused, in hospitals, hospital-type facilities, mobile, and home environments.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K092838 · printed Nov 4, 2026
Cite this page
510(k) Report. “K092838: Masimo Set Rad 8 Pulse Oximeter and Accessories, Model Rad 8.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K092838
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026