510(k) Report

510(k) · Cleared

Cleared

Reverse Shoulder Prosthesis

K092873510(k) SpecialCleared Oct 27, 200939-day reviewClass II21 CFR 888.3660

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Djo Surgical · PHX Shoulder Prosthesis, Reverse Configuration

Cleared on Oct 27, 2009 as substantially equivalent to K041066 (Encore Medical L.P., 2005) and 1 other predicate after a 39-day review. Its family tree reaches back 2 generations to 2005. 125 later devices descend from it.

Decided
Oct 27, 2009
Review
39 days
Class
Class II
Product code
PHX
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K041066 (2005). 125 later devices descend from it, 11 citing it directly.

Descendants, by year cleared 2026: 17 descendants cleared2017: 7 descendants cleared2013: 4 descendants cleared2015: 2 descendants cleared2014: 3 descendants cleared2010: 1 descendant cleared2011: 2 descendants cleared2020: 8 descendants cleared2019: 7 descendants cleared2024: 14 descendants cleared2022: 12 descendants cleared2016: 5 descendants cleared2023: 11 descendants cleared2018: 3 descendants cleared2025: 18 descendants cleared2021: 11 descendants cleared×2: 2 generations cleared close together, K041066 (2005), K051075 (2005) 20052010201520202025
Descendants, by generation 1 generation forward: 11 descendants2 generations forward: 20 descendants3 generations forward: 21 descendants4 generations forward: 24 descendants5 generations forward: 14 descendants6 generations forward: 13 descendants7 generations forward: 12 descendants8 generations forward: 8 descendants9 generations forward: 2 descendants K051075 · Encore Reverse Shoulder Prosthesis · Encore Medical L.P. · 2005 · recalledK041066 · Encore Reverse Shoulder Prosthesis · Encore Medical L.P. · 2005 · recalled0+5
  1. Root · 2 generations backK041066 Encore Reverse Shoulder ProsthesisEncore Medical L.P. · 2005 · Recalled
  2. 1 generation backK051075 Encore Reverse Shoulder ProsthesisEncore Medical L.P. · 2005 · Recalled
  3. This deviceK092873 Reverse Shoulder ProsthesisDjo Surgical · 2009
  4. Descendant · cites it directly · 74 of its ownK112069 RSP Glenoid Baseplate Porous CoatedEncore Medical L.P. · 2011 · Recalled
  5. Descendant · cites it directly · 65 of its ownK100741 Reverse Shoulder Prosthesis Monoblock Stem, Reverse Shoulder…Encore Medical L.P. · 2010 · Recalled
  6. Descendant · 2 generations on · 59 of its ownK130048 Reverse Shoulder Prosthesis MonoblockEncore Medical L.P. · 2013
  7. Descendant · 2 generations on · 55 of its ownK140904 RSP Monoblock Stem with P2 Coating, Size 6Encore Medical L.P. · 2014
  8. Descendant · cites it directly · 35 of its ownK131559 Match Point System (TM), Surgicase Connect, Match Point System (TM)…Materialise NV · 2013

Showing 5 of 125 descendants. See all descendants

Descendants cleared per year

2010: 12011: 22013: 42014: 32015: 22016: 52017: 72018: 32019: 72020: 82021: 112022: 122023: 112024: 142025: 182026: 17
2010high 18 (2025) · low 0 (2012)2026

Most influential descendants

Showing 5 of 125 · See all
  • K112069RSP Glenoid Baseplate Porous CoatedEncore Medical L.P. · 2011 · cites it directly74descendants
  • K100741Reverse Shoulder Prosthesis Monoblock Stem, Reverse Shoulder Prosthesis Humeral Inserts…Encore Medical L.P. · 2010 · cites it directly65descendants
  • K130048Reverse Shoulder Prosthesis MonoblockEncore Medical L.P. · 2013 · 2 generations on59descendants
  • K140904RSP Monoblock Stem with P2 Coating, Size 6Encore Medical L.P. · 2014 · 2 generations on55descendants
  • K131559Match Point System (TM), Surgicase Connect, Match Point System (TM) GuidesMaterialise NV · 2013 · cites it directly35descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K041066Encore Reverse Shoulder ProsthesisEncore Medical L.P.20054
−1K051075Encore Reverse Shoulder ProsthesisEncore Medical L.P.20055
0 (this device)K092873Reverse Shoulder ProsthesisDjo Surgical2009—
+1K112069RSP Glenoid Baseplate Porous CoatedEncore Medical L.P.20111
+1K100741Reverse Shoulder Prosthesis Monoblock Stem, Reverse Shoulder Prosthesis…Encore Medical L.P.20101
+2K130048Reverse Shoulder Prosthesis MonoblockEncore Medical L.P.2013—
+2K140904RSP Monoblock Stem with P2 Coating, Size 6Encore Medical L.P.2014—
+1K131559Match Point System (TM), Surgicase Connect, Match Point System (TM) GuidesMaterialise NV2013—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201010
201120
201340
201430
201520
201650
201770
201830
201970
202080
2021110
2022120
2023110
2024140
2025180
2026170
FIG. 1 — Lineage of K092873, 2005–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PHX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PHX device

  1. #1 K212737 INHANCE™ Reverse Shoulder Systemscore 28.4 · 15 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K041066Encore Reverse Shoulder Prosthesis
Summary page 4
…2) 834-6255 9800 Metric Blvd Fax: (512) 834-6313 Austin, TX 78758 Email: [email protected] Product 510(k) Number, Clearance Date/ Classification Product Code K041066 — March 24, 2005 Reverse® Shoulder Prosthesis K051075 — May 27, 2005 KWS Class II : Product Code Regulation and Classification Na…
Encore Medical L.P.20054
*K051075Encore Reverse Shoulder Prosthesis
Summary page 4
…n, TX 78758 Email: [email protected] Product 510(k) Number, Clearance Date/ Classification Product Code K041066 — March 24, 2005 Reverse® Shoulder Prosthesis K051075 — May 27, 2005 KWS Class II : Product Code Regulation and Classification Name KWS Shoulder joint metal/polymer semi-constrained p…
Encore Medical L.P.20055

Also cleared against K041066: 24 other devices →

What descends from it? (125)

See all 125

11 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K112069RSP Glenoid Baseplate Porous CoatedEncore Medical L.P.201174
K100741Reverse Shoulder Prosthesis Monoblock Stem, Reverse Shoulder Prosthesis Humeral Inserts…Encore Medical L.P.201065
K131559Match Point System (TM), Surgicase Connect, Match Point System (TM) GuidesMaterialise NV201335
K132285Aequalis Reversed Shoulder ProsthesisTornier S.A.S.201326
K141006RSP Humeral Socket InsertDjo Global201421
K151293Aequalis Ascend Flex Shoulder System, Aequalis Reversed Shoulder ProsthesisTornier S.A.S.201520
K233481AltiVate Reverse® GlenoidEncore Medical L.P.20244
K173073AltiVate Anatomic to Reverse Conversion ModuleEncore Medical L.P.20173
K252567AltiVate Reverse® ADLC GlenosphereEncore Medical L.P.20260
K201905SMR 140° Reverse Humeral BodyLima Corporate S.P.A.20200

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 4 years and passes through 2 companies; a new generation was cleared every 4.4 years on median.
  • 2 of the 2 ancestors have a recall of any class.
  • Of its descendants, K112069 (Encore Medical L.P., 2011) has gone furthest, with 74 descendants of its own.
  • 24 other devices also cite its predicate K041066.

How does its category compare?

All PHX devices

PHX Shoulder Prosthesis, Reverse Configuration: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · PHX

9in 2025

2007: 52008: 62009: 12010: 82011: 122012: 122013: 82014: 122015: 42016: 42017: 112018: 142019: 92020: 132021: 212022: 92023: 92024: 92025: 92026 (partial year): 18
2007high 21 (2021) · low 1 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PHX

72in 2025

2007: 97 days median2008: 79 days median2010: 124 days median2011: 94 days median2012: 114 days median2013: 143 days median2014: 110 days median2015: 206 days median2016: 132 days median2017: 141 days median2018: 127 days median2019: 144 days median2020: 143 days median2021: 143 days median2022: 198 days median2023: 154 days median2024: 139 days median2025: 72 days median2026 (partial year): 130 days median
2007high 206 (2015) · low 72 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · PHX

3in 2025

2015: 22018: 12019: 32020: 32021: 82023: 72024: 12025: 32026 (partial year): 7
2007high 8 (2021) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · PHX

2,848in 2025

2015: 142016: 52017: 252018: 3232019: 5042020: 9862021: 1,4042022: 1,3422023: 1,4012024: 2,1422025: 2,848
2007high 2,848 (2025) · low 0 (2007)2025

MAUDE reports naming product code PHX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200759700
200867900
20091—00
2010812400
2011129400
20121211400
2013814300
20141211000
20154206214
2016413205
201711141025
2018141271323
201991443504
2020131433986
20212114381,404
2022919801,342
2023915471,401
2024913912,142
202597232,848
2026181307—

What is it indicated for?

For treatment of patients with a grossly rotator cuff deficient shoulder joint with severe arthropathy or a previously failed joint replacement with a grossly rotator cuff deficient shoulder joint.

The patient’s joint must be anatomically and structurally suited to receive the selected implant(s), and a functional deltoid muscle is necessary to use the device.

The glenoid baseplate is intended for cementless application with the addition of screws for fixation. The humeral stem is intended for cemented use only.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K092873: Reverse Shoulder Prosthesis.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K092873

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026