510(k) Report

510(k) · Cleared

Cleared

Scalp Dura Retractor, Model KS00474

K093054510(k) TraditionalCleared Nov 15, 2010411-day reviewClass II21 CFR 882.4800

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

KARL STORZ Endoscopy-America, Inc. · GZT Retractor, Self-Retaining, For Neurosurgery

Cleared on Nov 15, 2010 as substantially equivalent to K060097 (KLS-Martin L.P., 2006) and 2 other predicates after a 411-day review. Its family tree reaches back 2 generations to 1983.

Decided
Nov 15, 2010
Review
411 days
Class
Class II
Product code
GZT
Recalls
None
Predicates
3

Its longest line of descent runs back 2 generations to K830332 (1983). 3 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 1996: 1 other ancestorK830332 · Budde-Halo Retractor · Ohio Medical Instrument Co., Inc. · 1983 · recalledK060097 · Grossman Self-Retaining Low Profile Brain Retractor, Model 04-001-00 · KLS-Martin L.P. · 20061980198519901995200020052010
  1. Root · 2 generations backK830332 Budde-Halo RetractorOhio Medical Instrument Co., Inc. · 1983 · Recalled
  2. 1 generation backK060097 Grossman Self-Retaining Low Profile Brain Retractor, Model 04-001-00KLS-Martin L.P. · 2006
  3. This deviceK093054 Scalp Dura Retractor, Model KS00474KARL STORZ Endoscopy-America, Inc. · 2010
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K830332Budde-Halo RetractorOhio Medical Instrument Co., Inc.19831
−1K060097Grossman Self-Retaining Low Profile Brain Retractor, Model 04-001-00KLS-Martin L.P.2006—
0 (this device)K093054Scalp Dura Retractor, Model KS00474KARL STORZ Endoscopy-America, Inc.2010—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199610
FIG. 1 — Lineage of K093054, 1983–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GZT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GZT device

  1. #1 K252995 Durashield Device Kitscore 12.6 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K060097Grossman Self-Retaining Low Profile Brain Retractor, Model 04-001-00KLS-Martin L.P.2006—
*K960807Tew Cranial/Spinal Retractor Model A1090
Summary page 1
…CFR 882.4800 GZT KLS-Martin, LP: Grossman Self-retaining Low Profile Brain Retractor (K0O60097) Ohio Medical Instrument Co.: TEW Cranial/Spinal Retractor Model A 1090 (K960807) Ohio Medical Instrument Co.: BUDDE Halc Retractor (K830332) Device Description: The Karl Storz Scalp Dura Retractor is a non-po…
Ohio Medical Instrument Co., Inc.1996—
*K830332Budde-Halo Retractor
Summary page 1
…ow Profile Brain Retractor (K0O60097) Ohio Medical Instrument Co.: TEW Cranial/Spinal Retractor Model A 1090 (K960807) Ohio Medical Instrument Co.: BUDDE Halc Retractor (K830332) Device Description: The Karl Storz Scalp Dura Retractor is a non-powered, manual, adjustable, self-retaining retractor for neu…
Ohio Medical Instrument Co., Inc.19831

Also cleared against K060097: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 27 years and passes through 3 companies; a new generation was cleared every 23.0 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • 1 other device also cites its predicate K060097.

How does its category compare?

All GZT devices

GZT Retractor, Self-Retaining, For Neurosurgery: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · GZT

1in 2022

2007: 22009: 12010: 12011: 12012: 22015: 12016: 12017: 32018: 12020: 12021: 12022: 12026 (partial year): 1
2007high 3 (2017) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GZT

280in 2017

2017: 280 days median
2007high 280 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GZT

1in 2012

2007: 12012: 1, 1 Class I
2007high 1 (2007) · low 0 (2008)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · GZT

1in 2025

2009: 12010: 42011: 42012: 62013: 122014: 162015: 42016: 52017: 92018: 32019: 52020: 32021: 22022: 42023: 22024: 82025: 1
2007high 16 (2014) · low 0 (2007)2025

MAUDE reports naming product code GZT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—10
20080—00
20091—01
20101—04
20111—04
20122—1 (1)6
20130—012
20140—016
20151—04
20161—05
2017328009
20181—03
20190—05
20201—03
20211—02
20221—04
20230—02
20240—08
20250—01
20261—0—

What is it indicated for?

The Karl Storz Scalp Dura Retractor is intended for use to

elevate dura and scalp layers away from cranial bone

during endoscopic-assisted strip craniectomies.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K093054: Scalp Dura Retractor, Model KS00474.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K093054

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026