Finesse Personal Insulin Delivery Patch, Model FG-2000

K093065510(k) TraditionalCleared Jan 20, 2010112-day reviewClass II21 CFR 880.5725

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Calibra Medical, Inc. · OPP Pump, Infusion, Insulin Bolus

Cleared on Jan 20, 2010 as substantially equivalent to K053563 (Eli Lilly and Company, 2006) and 1 other predicate after a 112-day review. Its family tree reaches back 2 generations to 2003. 6 later devices descend from it.

Decided
Jan 20, 2010
Review
112 days
Class
Class II
Product code
OPP
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K031373 (2003). 4 ancestors in all, the oldest K010359 (2001). 6 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2006: 1 other ancestor2001: 1 other ancestor2010: 1 descendant cleared2012: 1 descendant cleared2024: 2 descendants cleared2017: 1 descendant cleared2026: 1 descendant clearedK031373 · Ixl Diabetes Management System · Insulet Corp. · 2003K050971 · Biovalve Insulin Delivery Systems (Bids) · Biovalve Technologies, Inc. · 2005200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 1 other ancestor 1 generation forward: 3 descendants2 generations forward: 3 descendants K050971 · Biovalve Insulin Delivery Systems (Bids) · Biovalve Technologies, Inc. · 2005K031373 · Ixl Diabetes Management System · Insulet Corp. · 20030
  1. Root · 2 generations backK031373 Ixl Diabetes Management SystemInsulet Corp. · 2003
  2. 1 generation backK050971 Biovalve Insulin Delivery Systems (Bids)Biovalve Technologies, Inc. · 2005
  3. This deviceK093065 Finesse Personal Insulin Delivery Patch, Model FG-2000Calibra Medical, Inc. · 2010
  4. Descendant · cites it directly · 5 of its ownK100947 Finesse Personal Insulin Delivery Patch, Model FG 2000Calibra Medical, Inc. · 2010
  5. Descendant · cites it directly · 4 of its ownK111924 Finesse Personal Insulin Delivery PatchCalibra Medical, Inc. · 2012
  6. Descendant · 2 generations on · 3 of its ownK163357 OneTouch Via On-Demand Insulin Delivery SystemLifescan Europe, A Division of Cilag GmbH · 2017
  7. Descendant · 2 generations on · 2 of its ownK233447 CeQur Simplicity™ On-Demand Insulin Delivery SystemCequr SA · 2024
  8. Descendant · cites it directly · 1 of its ownK243273 CeQur Simplicity™ On-Demand Insulin Delivery SystemCequr SA · 2024

Showing 5 of 6 descendants. See all descendants

Descendants cleared per year

2010: 12012: 12017: 12024: 22026: 1
2010high 2 (2024) · low 0 (2011)2026

Most influential descendants

Showing 5 of 6 · See all
  • K100947Finesse Personal Insulin Delivery Patch, Model FG 2000Calibra Medical, Inc. · 2010 · cites it directly5descendants
  • K111924Finesse Personal Insulin Delivery PatchCalibra Medical, Inc. · 2012 · cites it directly4descendants
  • K163357OneTouch Via On-Demand Insulin Delivery SystemLifescan Europe, A Division of Cilag GmbH · 2017 · 2 generations on3descendants
  • K233447CeQur Simplicity™ On-Demand Insulin Delivery SystemCequr SA · 2024 · 2 generations on2descendants
  • K243273CeQur Simplicity™ On-Demand Insulin Delivery SystemCequr SA · 2024 · cites it directly1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K031373Ixl Diabetes Management SystemInsulet Corp.2003—
−1K050971Biovalve Insulin Delivery Systems (Bids)Biovalve Technologies, Inc.2005—
0 (this device)K093065Finesse Personal Insulin Delivery Patch, Model FG-2000Calibra Medical, Inc.2010—
+1K100947Finesse Personal Insulin Delivery Patch, Model FG 2000Calibra Medical, Inc.2010—
+1K111924Finesse Personal Insulin Delivery PatchCalibra Medical, Inc.2012—
+2K163357OneTouch Via On-Demand Insulin Delivery SystemLifescan Europe, A Division of Cilag GmbH2017—
+2K233447CeQur Simplicity™ On-Demand Insulin Delivery SystemCequr SA2024—
+1K243273CeQur Simplicity™ On-Demand Insulin Delivery SystemCequr SA2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200110
200610

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201010
201210
201710
202420
202610
FIG. 1 — Lineage of K093065, 2003–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OPP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OPP device

  1. #1 K233447 CeQur Simplicity™ On-Demand Insulin Delivery…score 14.2 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K053563Humapen Memoir
Summary page 2
…Medical, Inc. believes that the System described inthis Submission is substantially equivalent to a combination of the Eli Lilly and Company HumaPen Memoir (K(053563) and the Biovalve Insulin Delivery System (K050971). 7. Device Description The Finesse Insulin Delivery System is…
Eli Lilly and Company2006—
*K050971Biovalve Insulin Delivery Systems (Bids)
Summary page 2
…s Submission is substantially equivalent to a combination of the Eli Lilly and Company HumaPen Memoir (K(053563) and the Biovalve Insulin Delivery System (K050971). 7. Device Description The Finesse Insulin Delivery System is a sterile, nonpyrogenic, single-use, external, disp…
Biovalve Technologies, Inc.2005—

What descends from it? (6)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K100947Finesse Personal Insulin Delivery Patch, Model FG 2000Calibra Medical, Inc.20105
K111924Finesse Personal Insulin Delivery PatchCalibra Medical, Inc.20124
K243273CeQur Simplicity™ On-Demand Insulin Delivery SystemCequr SA20241

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 7 years and passes through 3 companies; a new generation was cleared every 4.4 years on median.
  • None of the 4 ancestors has a recall.
  • Of its descendants, K100947 (Calibra Medical, Inc., 2010) has gone furthest, with 5 descendants of its own.

How does its category compare?

All OPP devices

OPP Pump, Infusion, Insulin Bolus: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · OPP

2in 2024

2010: 22012: 12017: 12024: 22026 (partial year): 1
2007high 2 (2010) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OPP

Too few OPP 510(k)s in any year since 2007 to give a median.

Recalls per year · OPP

1in 2011

2011: 1
2007high 1 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OPP

1in 2025

2015: 222016: 32017: 62025: 1
2007high 22 (2015) · low 0 (2007)2025

MAUDE reports naming product code OPP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20102—00
20110—10
20121—00
20130—00
20140—00
20150—022
20160—03
20171—06
20180—00
20190—00
20200—00
20210—00
20220—00
20230—00
20242—00
20250—01
20261—0—

What is it indicated for?

The Finesse Insulin Delivery System is intended for subcutaneous,

bolus delivery of insulin for the management of diabetes mellitus in

persons requiring insulin.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K093065: Finesse Personal Insulin Delivery Patch, Model FG-2000.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K093065

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026