3.0T 16 Channel Head Neck Spine Coil

K093348510(k) TraditionalCleared Nov 25, 200929-day reviewClass II21 CFR 892.1000

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ge Healthcare Coils (Usa Instruments, Inc.) · MOS Coil, Magnetic Resonance, Specialty

Cleared on Nov 25, 2009 as substantially equivalent to K052916 (Usa Instruments, Inc., 2005) after a 29-day review. Its family tree reaches back 3 generations to 2000. 3 later devices descend from it.

Decided
Nov 25, 2009
Review
29 days
Class
Class II
Product code
MOS
Recalls
None
Predicates
2

Its longest line of descent runs back 3 generations to K001870 (2000). 3 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2012: 1 descendant cleared2014: 1 descendant cleared2019: 1 descendant clearedK001870 · Millennium 9000 Phased Array Neurovascular Coil · Usa Instruments, Inc. · 2000K032618 · 3.0T 8 Channel Neurovascular (NV) Array Coil · Usa Instruments, Inc. · 2003K052916 · Usa Instruments 3.0T Brain/Spine Array · Usa Instruments, Inc. · 2005 · recalled200020052010201520202025
  1. Root · 3 generations backK001870 Millennium 9000 Phased Array Neurovascular CoilUsa Instruments, Inc. · 2000
  2. 2 generations backK032618 3.0T 8 Channel Neurovascular (NV) Array CoilUsa Instruments, Inc. · 2003
  3. 1 generation backK052916 Usa Instruments 3.0T Brain/Spine ArrayUsa Instruments, Inc. · 2005 · Recalled
  4. This deviceK093348 3.0T 16 Channel Head Neck Spine CoilGe Healthcare Coils (Usa Instruments, Inc.) · 2009
  5. Descendant · cites it directly · 2 of its ownK113365 Infant ArrayAdvanced Imaging Research Dba Sree Medical Systems · 2012
  6. Descendant · 2 generations on · 1 of its ownK140998 Pediatric 16, A1.5T Tim Coil/Pediatric 16, A3T Tim CoilQuality Electrodynamics, LLC · 2014
  7. Descendant · 3 generations on · 0 of its ownK183186 Head Coil – 12, Head Coil – 32, Carotid Coil – 8, Temporomandibular…Shanghai United Imaging Healthcare Co., Ltd. · 2019

Most influential descendants

Showing 3 of 3 · See all
  • K113365Infant ArrayAdvanced Imaging Research Dba Sree Medical Systems · 2012 · cites it directly2descendants
  • K140998Pediatric 16, A1.5T Tim Coil/Pediatric 16, A3T Tim CoilQuality Electrodynamics, LLC · 2014 · 2 generations on1descendant
  • K183186Head Coil – 12, Head Coil – 32, Carotid Coil – 8, Temporomandibular Joint Coil – 4…Shanghai United Imaging Healthcare Co., Ltd. · 2019 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K001870Millennium 9000 Phased Array Neurovascular CoilUsa Instruments, Inc.2000—
−2K0326183.0T 8 Channel Neurovascular (NV) Array CoilUsa Instruments, Inc.2003—
−1K052916Usa Instruments 3.0T Brain/Spine ArrayUsa Instruments, Inc.20051
0 (this device)K0933483.0T 16 Channel Head Neck Spine CoilGe Healthcare Coils (Usa Instruments, Inc.)2009—
+1K113365Infant ArrayAdvanced Imaging Research Dba Sree Medical Systems2012—
+2K140998Pediatric 16, A1.5T Tim Coil/Pediatric 16, A3T Tim CoilQuality Electrodynamics, LLC2014—
+3K183186Head Coil – 12, Head Coil – 32, Carotid Coil – 8, Temporomandibular Joint Coil…Shanghai United Imaging Healthcare Co., Ltd.2019—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201210
201410
201910
FIG. 1 — Lineage of K093348, 2000–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MOS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MOS device

  1. #1 K253738 3.0T Air 32CH Hnascore 15.2 · 16 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.

TypeNumberDeviceApplicantDecidedRecalls
*K052916Usa Instruments 3.0T Brain/Spine Array
Summary page 2
…Product Code: 90MOS Predicate Device(s): (1) 3.OT 16 Channel Brain/Spine (Neurovascular) Array Coil (K052916) (2) 1.5T 16 Channel Brain/Spine Coil (K052612) Device Description: The 3.OT Hea…
Usa Instruments, Inc.20051
Kept off the family treeK052612FDA’s K052612 is Disposable Powder Free Vinyl Exam Gloves with Vitamin Complex, Nopal and…
Our reading of the summary gave K052612, FDA’s number for Disposable Powder Free Vinyl Exam Gloves with Vitamin… (Shanghai Antares Industries, Inc.). Its FDA name has none of the distinctive words the summary uses for the device it names, “1.5T 16 Channel Brain/Spine Coil”. Kept off the family tree.
Summary page 2
…3.OT 16 Channel Brain/Spine (Neurovascular) Array Coil (K052916) (2) 1.5T 16 Channel Brain/Spine Coil (K052612) Device Description: The 3.OT Head Neck and Spine CoilI s a receive-only 16-channel,…
Shanghai Antares Industries, Inc.2005—

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K113365Infant ArrayAdvanced Imaging Research Dba Sree Medical Systems20122

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 9 years and passes through 2 companies; a new generation was cleared every 3.1 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • Of its descendants, K113365 (Advanced Imaging Research Dba Sree Medical Systems, 2012) has gone furthest, with 2 descendants of its own.

How does its category compare?

All MOS devices

MOS Coil, Magnetic Resonance, Specialty: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · MOS

3in 2025

2007: 162008: 192009: 102010: 162011: 252012: 152013: 72014: 122015: 62016: 112017: 92018: 102019: 32020: 52021: 42022: 112023: 102024: 102025: 32026 (partial year): 10
2007high 25 (2011) · low 3 (2019)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MOS

59in 2025

2007: 19 days median2008: 33 days median2009: 43 days median2010: 78 days median2011: 57 days median2012: 49 days median2013: 87 days median2014: 60 days median2015: 58 days median2016: 42 days median2017: 63 days median2018: 30 days median2019: 178 days median2020: 51 days median2021: 41 days median2022: 79 days median2023: 59 days median2024: 39 days median2025: 59 days median2026 (partial year): 45 days median
2007high 178 (2019) · low 19 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MOS

13in 2024

2008: 22010: 12012: 12015: 22019: 82020: 12024: 13
2007high 13 (2024) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MOS

2in 2025

2007: 42008: 22009: 52010: 132011: 72012: 122013: 102014: 42015: 52016: 72017: 92018: 72019: 82020: 22021: 32022: 52023: 42024: 82025: 2
2007high 13 (2010) · low 2 (2008)2025

MAUDE reports naming product code MOS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007161904
2008193322
2009104305
20101678113
2011255707
20121549112
2013787010
2014126004
201565825
2016114207
201796309
2018103007
2019317888
202055112
202144103
2022117905
2023105904
20241039138
202535902
202610450—

What is it indicated for?

The GE 3.OT 16 Channel Head Neck Spine Coil is a receive-only RF coil designed for use with the 3.OT MIR system manufactured by GE Healthcare. The coil is intended for imaging of the brain; cervical, thoracic and lumbar spines; as well as the soft tissues and vasculature of the head, neck, and upper chest. The nucleus excited is hydrogen.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K093348: 3.0T 16 Channel Head Neck Spine Coil.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K093348

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026