510(k) Report

510(k) · Cleared

Cleared

Gdxpro

K093521510(k) TraditionalCleared Nov 25, 200912-day reviewClass II21 CFR 886.1570

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Carl Zeiss Meditec, Inc. · MYC Ophthalmoscope, Laser, Scanning

Cleared on Nov 25, 2009 as substantially equivalent to K082016 (Carl Zeiss Meditec, Inc., 2009) after a 12-day review. Its family tree reaches back 3 generations to 2002.

Decided
Nov 25, 2009
Review
12 days
Class
Class II
Product code
MYC
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K012727 (2002). 4 ancestors in all, the oldest K941705 (1994). No later device cites it as a predicate yet.

  1. Root · 3 generations backK012727 Humphrey OCT3Carl Zeiss Ophthalmic Systems, Inc. · 2002
  2. 2 generations backK030433 Stratusoct with RNFL Normative DatabaseCarl Zeiss Meditec, Inc. · 2003 · Recalled
  3. 1 generation backK082016 GDX VCC with Ecc SoftwareCarl Zeiss Meditec, Inc. · 2009
  4. This deviceK093521 GdxproCarl Zeiss Meditec, Inc. · 2009
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K012727Humphrey OCT3Carl Zeiss Ophthalmic Systems, Inc.2002—
−2K030433Stratusoct with RNFL Normative DatabaseCarl Zeiss Meditec, Inc.20031
−1K082016GDX VCC with Ecc SoftwareCarl Zeiss Meditec, Inc.2009—
0 (this device)K093521GdxproCarl Zeiss Meditec, Inc.2009—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
FIG. 1 — Lineage of K093521, 2002–2009Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MYC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MYC device

  1. #1 K261255 Kowa FM-600score 12.3 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K082016GDX VCC with Ecc Software
Summary page 1
…DEVICE Company: Carl Zeiss Meditec, Inc. Device: GDx with ECC Retinal Nerve Fiber Layer Normative Database (K082016) GDxPROT M 510(k) PremarketNotoicati…
Carl Zeiss Meditec, Inc.2009—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 7 years and passes through 2 companies; a new generation was cleared every 1.2 years on median.
  • 1 of the 4 ancestors has a recall of any class.

How does its category compare?

All MYC devices

MYC Ophthalmoscope, Laser, Scanning: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · MYC

2in 2025

2008: 12009: 32010: 22011: 22013: 12014: 22015: 22016: 12018: 22019: 12021: 22025: 22026 (partial year): 1
2007high 3 (2009) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MYC

116in 2009

2009: 116 days median
2007high 116 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MYC

No recall names MYC since 2007.

Adverse event reports per year · MYC

2in 2023

2021: 12023: 2
2007high 2 (2023) · low 0 (2007)2025

MAUDE reports naming product code MYC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20081—00
2009311600
20102—00
20112—00
20120—00
20131—00
20142—00
20152—00
20161—00
20170—00
20182—00
20191—00
20200—00
20212—01
20220—00
20230—02
20240—00
20252—00
20261—0—

What is it indicated for?

The GDx is a confocal polarimetric scanning laser ophthalmoscope that is intended for imaging and three-dimensional analysis of the fundus and retinal nerve fiber layer (RNFL) in vivo. The GDx and its GDx Variable Corneal Compensation (VCC) and GDx Enhanced Corneal Compensation (ECC) RNFL Normative Databases aid in the diagnosis and monitoring of diseases and disorders of the eye that may cause changes in the polarimetric retinal nerve fiber layer thickness. The GDx is to be used in patients who may have an optic neuropathy.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K093521: Gdxpro.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K093521

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026