510(k) Report

510(k) · Cleared

Cleared

Aequalis Reversed Shoulder Prosthesis

K100142510(k) TraditionalCleared May 6, 2010107-day reviewClass II21 CFR 888.3660

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Tornier · PHX Shoulder Prosthesis, Reverse Configuration

Cleared on May 6, 2010 as substantially equivalent to K030941 (Tornier, 2004) and 8 other predicates after a 107-day review. Its family tree reaches back 10 generations to 1991. 147 later devices descend from it.

Decided
May 6, 2010
Review
107 days
Class
Class II
Product code
PHX
Recalls
None
Predicates
9

Its longest line of descent runs back 10 generations to K911686 (1991). 41 ancestors in all, the oldest K800494 (1980). 147 later devices descend from it, 10 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2009: 1 other ancestor2008: 2 other ancestors2007: 2 other ancestors2006: 3 other ancestors2004: 2 other ancestors2003: 2 other ancestors2001: 3 other ancestors2000: 4 other ancestors1999: 3 other ancestors1995: 1 other ancestor1998: 1 other ancestor1996: 1 other ancestor1987: 1 other ancestor1980: 2 other ancestors2005: 1 other ancestor1993: 1 other ancestor1992: 1 other ancestor2015: 4 descendants cleared2013: 5 descendants cleared2011: 3 descendants cleared2017: 9 descendants cleared2014: 8 descendants cleared2012: 1 descendant cleared2023: 13 descendants cleared2018: 11 descendants cleared2016: 3 descendants cleared2022: 17 descendants cleared2019: 12 descendants cleared2021: 12 descendants cleared2020: 11 descendants cleared2024: 10 descendants cleared2025: 14 descendants cleared2026: 14 descendants clearedK911686 · Global Total Shoulder, Uncement Humeral Hemi-Shoul · Depuy, Inc. · 1991K984541 · Global FX Humeral Stem, Global Advantage Humeral Head · DePuy Orthopaedics, Inc. · 1999K992065 · Global Advantage Shoulder, Global Advantage Humeral Stem, Global Advantage Eccentric Head · DePuy Orthopaedics, Inc. · 1999K021478 · Delta Shoulder · Depuy, Inc. · 2003×2: 2 generations cleared close together, K030941 (2004), K041873 (2004) K050316 · Aequalis Reversed Shoulder Prosthesis · Tornier · 2005K061439 · Aequalis Reversed Prosthesis · Tornier · 2006K071948 · Aequalis Reversed Adapter · Tornier · 2007K082120 · Aequalis Reversed Fracture Shoulder Prothesis · Tornier · 200819801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 4 other ancestors2 generations back: 12 other ancestors3 generations back: 8 other ancestors4 generations back: 4 other ancestors5 generations back: 3 other ancestors 1 generation forward: 10 descendants2 generations forward: 33 descendants3 generations forward: 25 descendants4 generations forward: 27 descendants5 generations forward: 31 descendants6 generations forward: 18 descendants7 generations forward: 3 descendants K082120 · Aequalis Reversed Fracture Shoulder Prothesis · Tornier · 2008K071948 · Aequalis Reversed Adapter · Tornier · 2007K061439 · Aequalis Reversed Prosthesis · Tornier · 2006K050316 · Aequalis Reversed Shoulder Prosthesis · Tornier · 2005K041873 · Aequalis Reversed Shoulder Prosthesis · Tornier · 2004K030941 · Aequalis Reversed Shoulder Prosthesis · Tornier · 2004K021478 · Delta Shoulder · Depuy, Inc. · 2003K992065 · Global Advantage Shoulder, Global Advantage Humeral Stem, Global Advantage Eccentric Head · DePuy Orthopaedics, Inc. · 1999K984541 · Global FX Humeral Stem, Global Advantage Humeral Head · DePuy Orthopaedics, Inc. · 1999K911686 · Global Total Shoulder, Uncement Humeral Hemi-Shoul · Depuy, Inc. · 1991−10−50+5
  1. Root · 10 generations backK911686 Global Total Shoulder, Uncement Humeral Hemi-ShoulDepuy, Inc. · 1991
  2. 6 generations between
  3. 3 generations backK061439 Aequalis Reversed ProsthesisTornier · 2006
  4. 2 generations backK071948 Aequalis Reversed AdapterTornier · 2007
  5. 1 generation backK082120 Aequalis Reversed Fracture Shoulder ProthesisTornier · 2008
  6. This deviceK100142 Aequalis Reversed Shoulder ProsthesisTornier · 2010
  7. Descendant · cites it directly · 108 of its ownK110599 Aequalis Ascend Modular Reverse Shoulder SystemTornier, Inc. · 2011
  8. Descendant · 2 generations on · 97 of its ownK112615 Aequalis Ascend Modular Reverse Shoulder SystemTornier, Inc. · 2011
  9. Descendant · 3 generations on · 96 of its ownK122698 Aequalis Ascend Flex Shoulder SystemTornier S.A.S. · 2013 · Recalled
  10. Descendant · 4 generations on · 29 of its ownK140082 Aequalis (TM) Ascent (TM) Flex Shoulder SystemTornier S.A.S. · 2014
  11. Descendant · cites it directly · 28 of its ownK130129 Univers Revers Shoulder Prosthesis SystemArthrex, Inc. · 2013
Show all 10 generations
  1. Root · 10 generations backK911686 Global Total Shoulder, Uncement Humeral Hemi-ShoulDepuy, Inc. · 1991
  2. 9 generations backK984541 Global FX Humeral Stem, Global Advantage Humeral HeadDePuy Orthopaedics, Inc. · 1999
  3. 8 generations backK992065 Global Advantage Shoulder, Global Advantage Humeral Stem, Global…DePuy Orthopaedics, Inc. · 1999
  4. 7 generations backK021478 Delta ShoulderDepuy, Inc. · 2003
  5. 6 generations backK030941 Aequalis Reversed Shoulder ProsthesisTornier · 2004
  6. 5 generations backK041873 Aequalis Reversed Shoulder ProsthesisTornier · 2004
  7. 4 generations backK050316 Aequalis Reversed Shoulder ProsthesisTornier · 2005
  8. 3 generations backK061439 Aequalis Reversed ProsthesisTornier · 2006
  9. 2 generations backK071948 Aequalis Reversed AdapterTornier · 2007
  10. 1 generation backK082120 Aequalis Reversed Fracture Shoulder ProthesisTornier · 2008
  11. This deviceK100142 Aequalis Reversed Shoulder ProsthesisTornier · 2010

Showing 5 of 147 descendants. See all descendants

Descendants cleared per year

2011: 32012: 12013: 52014: 82015: 42016: 32017: 92018: 112019: 122020: 112021: 122022: 172023: 132024: 102025: 142026: 14
2011high 17 (2022) · low 1 (2012)2026

Most influential descendants

Showing 5 of 147 · See all
  • K110599Aequalis Ascend Modular Reverse Shoulder SystemTornier, Inc. · 2011 · cites it directly108descendants
  • K112615Aequalis Ascend Modular Reverse Shoulder SystemTornier, Inc. · 2011 · 2 generations on97descendants
  • K122698Aequalis Ascend Flex Shoulder SystemTornier S.A.S. · 2013 · 3 generations on96descendants
  • K140082Aequalis (TM) Ascent (TM) Flex Shoulder SystemTornier S.A.S. · 2014 · 4 generations on29descendants
  • K130129Univers Revers Shoulder Prosthesis SystemArthrex, Inc. · 2013 · cites it directly28descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K911686Global Total Shoulder, Uncement Humeral Hemi-ShoulDepuy, Inc.1991—
−9K984541Global FX Humeral Stem, Global Advantage Humeral HeadDePuy Orthopaedics, Inc.1999—
−8K992065Global Advantage Shoulder, Global Advantage Humeral Stem, Global Advantage…DePuy Orthopaedics, Inc.1999—
−7K021478Delta ShoulderDepuy, Inc.2003—
−6K030941Aequalis Reversed Shoulder ProsthesisTornier2004—
−5K041873Aequalis Reversed Shoulder ProsthesisTornier2004—
−4K050316Aequalis Reversed Shoulder ProsthesisTornier2005—
−3K061439Aequalis Reversed ProsthesisTornier2006—
−2K071948Aequalis Reversed AdapterTornier2007—
−1K082120Aequalis Reversed Fracture Shoulder ProthesisTornier2008—
0 (this device)K100142Aequalis Reversed Shoulder ProsthesisTornier2010—
+1K110599Aequalis Ascend Modular Reverse Shoulder SystemTornier, Inc.2011—
+2K112615Aequalis Ascend Modular Reverse Shoulder SystemTornier, Inc.2011—
+3K122698Aequalis Ascend Flex Shoulder SystemTornier S.A.S.20132
+4K140082Aequalis (TM) Ascent (TM) Flex Shoulder SystemTornier S.A.S.2014—
+1K130129Univers Revers Shoulder Prosthesis SystemArthrex, Inc.2013—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198020
198710
199210
199310
199510
199610
199810
199930
200040
200130
200320
200420
200510
200630
200720
200820
200910

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201130
201210
201350
201480
201540
201630
201790
2018110
2019120
2020110
2021120
2022170
2023130
2024100
2025140
2026140
FIG. 1 — Lineage of K100142, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PHX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PHX device

  1. #1 K212737 INHANCE™ Reverse Shoulder Systemscore 28.4 · 15 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (9)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K030941Aequalis Reversed Shoulder Prosthesis
Summary page 5
…n Device class: Class 11 Classification panel: Orthopedic Product code: KWS, HSD 5) Equivalent/ Predicate device A Aequalis Reversed Shoulder Prosthesis, TORNIER SA, K030941, K041873, K050316, K061439, K081059. Aequalis Reversed Fracture Shoulder System, TORNIER SA, K082120. Delta Xtend Reverse Shoul…
Tornier2004—
*K041873Aequalis Reversed Shoulder Prosthesis
Summary page 5
…class: Class 11 Classification panel: Orthopedic Product code: KWS, HSD 5) Equivalent/ Predicate device A Aequalis Reversed Shoulder Prosthesis, TORNIER SA, K030941, K041873, K050316, K061439, K081059. Aequalis Reversed Fracture Shoulder System, TORNIER SA, K082120. Delta Xtend Reverse Shoulder Syste…
Tornier2004—
*K050316Aequalis Reversed Shoulder Prosthesis
Summary page 5
…lass 11 Classification panel: Orthopedic Product code: KWS, HSD 5) Equivalent/ Predicate device A Aequalis Reversed Shoulder Prosthesis, TORNIER SA, K030941, K041873, K050316, K061439, K081059. Aequalis Reversed Fracture Shoulder System, TORNIER SA, K082120. Delta Xtend Reverse Shoulder System, DEPUY,…
Tornier2005—
*K061439Aequalis Reversed Prosthesis
Summary page 5
…lassification panel: Orthopedic Product code: KWS, HSD 5) Equivalent/ Predicate device A Aequalis Reversed Shoulder Prosthesis, TORNIER SA, K030941, K041873, K050316, K061439, K081059. Aequalis Reversed Fracture Shoulder System, TORNIER SA, K082120. Delta Xtend Reverse Shoulder System, DEPUY, K062250,…
Tornier2006—
*K081059Aequalis Reversed Shoulder Prosthesis
Summary page 5
…tion panel: Orthopedic Product code: KWS, HSD 5) Equivalent/ Predicate device A Aequalis Reversed Shoulder Prosthesis, TORNIER SA, K030941, K041873, K050316, K061439, K081059. Aequalis Reversed Fracture Shoulder System, TORNIER SA, K082120. Delta Xtend Reverse Shoulder System, DEPUY, K062250, K071379,…
Tornier2008—
*K082120Aequalis Reversed Fracture Shoulder Prothesis
Summary page 5
…dicate device A Aequalis Reversed Shoulder Prosthesis, TORNIER SA, K030941, K041873, K050316, K061439, K081059. Aequalis Reversed Fracture Shoulder System, TORNIER SA, K082120. Delta Xtend Reverse Shoulder System, DEPUY, K062250, K071379, K091751. Section 5 - Page 1/ page 4 (o> TORNIER S.A.S. Tél : 33…
Tornier2008—
*K062250Delta Xtend Reverse Shoulder System
Summary page 5
…, TORNIER SA, K030941, K041873, K050316, K061439, K081059. Aequalis Reversed Fracture Shoulder System, TORNIER SA, K082120. Delta Xtend Reverse Shoulder System, DEPUY, K062250, K071379, K091751. Section 5 - Page 1/ page 4 (o> TORNIER S.A.S. Tél : 33(0)476 61 3500 ) S.A.S. au capital dc 288 G600 € O 1 1…
DePuy Orthopaedics, Inc.20078
*K071379Delta Xtend Reverse Shoulder Modular Stem
Summary page 5
…SA, K030941, K041873, K050316, K061439, K081059. Aequalis Reversed Fracture Shoulder System, TORNIER SA, K082120. Delta Xtend Reverse Shoulder System, DEPUY, K062250, K071379, K091751. Section 5 - Page 1/ page 4 (o> TORNIER S.A.S. Tél : 33(0)476 61 3500 ) S.A.S. au capital dc 288 G600 € O 1 161. rue L…
DePuy Orthopaedics, Inc.2007—
*K091751Depuy Delta Xtend Reverse Shoulder XLK Cup
Summary page 5
…941, K041873, K050316, K061439, K081059. Aequalis Reversed Fracture Shoulder System, TORNIER SA, K082120. Delta Xtend Reverse Shoulder System, DEPUY, K062250, K071379, K091751. Section 5 - Page 1/ page 4 (o> TORNIER S.A.S. Tél : 33(0)476 61 3500 ) S.A.S. au capital dc 288 G600 € O 1 161. rue Lavoisier…
DePuy Orthopaedics, Inc.2009—

Also cleared against K030941: 16 other devices →

What descends from it? (147)

See all 147

10 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K110599Aequalis Ascend Modular Reverse Shoulder SystemTornier, Inc.2011108
K130129Univers Revers Shoulder Prosthesis SystemArthrex, Inc.201328
K132285Aequalis Reversed Shoulder ProsthesisTornier S.A.S.201326
K140478Aequalis Reversed Shoulder ProsthesisTornier S.A.S.201421
K151293Aequalis Ascend Flex Shoulder System, Aequalis Reversed Shoulder ProsthesisTornier S.A.S.201520
K133349SMR TT Metal Back GlenoidLima Corporate S.P.A.201420
K162455Humelock Reversed ShoulderFx Solutions201717
K120739Aequalis Adjustable Modular Reverse Shoulder SystemTornier, Inc.201212
K103251Duocentric ReversedAston Medical20117
K131231Aequalis Shoulder Fracture System, Aequalis Reversed Shoulder Prosthesis, Aequalis…Tornier S.A.S.20135

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 19 years and passes through 3 companies; a new generation was cleared every 1.2 years on median.
  • 6 of the 41 ancestors have a recall of any class.
  • Of its descendants, K110599 (Tornier, Inc., 2011) has gone furthest, with 108 descendants of its own.
  • 16 other devices also cite its predicate K030941.

How does its category compare?

All PHX devices

PHX Shoulder Prosthesis, Reverse Configuration: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · PHX

9in 2025

2007: 52008: 62009: 12010: 82011: 122012: 122013: 82014: 122015: 42016: 42017: 112018: 142019: 92020: 132021: 212022: 92023: 92024: 92025: 92026 (partial year): 18
2007high 21 (2021) · low 1 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PHX

72in 2025

2007: 97 days median2008: 79 days median2010: 124 days median2011: 94 days median2012: 114 days median2013: 143 days median2014: 110 days median2015: 206 days median2016: 132 days median2017: 141 days median2018: 127 days median2019: 144 days median2020: 143 days median2021: 143 days median2022: 198 days median2023: 154 days median2024: 139 days median2025: 72 days median2026 (partial year): 130 days median
2007high 206 (2015) · low 72 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · PHX

3in 2025

2015: 22018: 12019: 32020: 32021: 82023: 72024: 12025: 32026 (partial year): 7
2007high 8 (2021) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · PHX

2,848in 2025

2015: 142016: 52017: 252018: 3232019: 5042020: 9862021: 1,4042022: 1,3422023: 1,4012024: 2,1422025: 2,848
2007high 2,848 (2025) · low 0 (2007)2025

MAUDE reports naming product code PHX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200759700
200867900
20091—00
2010812400
2011129400
20121211400
2013814300
20141211000
20154206214
2016413205
201711141025
2018141271323
201991443504
2020131433986
20212114381,404
2022919801,342
2023915471,401
2024913912,142
202597232,848
2026181307—

What is it indicated for?

Cemented Acqualis Reversed prosthesis: It is indicated for patients with a functional deltoid muscle as a total shoulder replacement for the relief of pain and significant disability following arthropathy associated with the massive and non repairable rotator cuff-tear. This device is also indicated for the prosthetic revisions with massive and non repairable rotator cuff-tear. Only the humeral components are for cemented use. The glenoid implant is…

Read the full statement (397 words)

Cemented Acqualis Reversed prosthesis:

It is indicated for patients with a functional deltoid muscle as a total shoulder replacement for the relief of pain and significant disability following arthropathy associated with the massive and non repairable rotator cuff-tear. This device is also indicated for the prosthetic revisions with massive and non repairable rotator cuff-tear. Only the humeral components are for cemented use. The glenoid implant is anchored to the bone with 4 screws and is for non-cemented fixation.

When during the primary surgery the glenoid bone stock appears to be insufficient to bear the reversed glenoid components or when glenoid bone fracture occurs during the surgical procedures, the hemi-prosthesis adaptor and the union screw can be adapted to the humeral components in order to transform the Aequalis Reversed prosthesis into a non reversed hemi-prosthesis.

When, in case of revision of a Aequalis Reversed prosthesis, the glenoid bone stock appears to be insufficient to again implant a base plate and a sphere of Aequalis Reversed range, the use of the hemi-prosthesis adaptor and the union screw allows for the transformation of the Aequalis Reversed prosthesis in to a non reversed hemi-prosthesis in order to avoid the revision of the humeral components.

Uncemented Aequalis Reversed prosthesis:

It is indicated for patients with a functional deltoid muscle as a total shoulder replacement for the relief of pain and significant disability following arthropathy associated to massive and non repairable rotator cuff-tear. This device is also indicated for the prosthetic revisions with massive and non repairable rotator cuff-tear. The humeral components are for non-cemented use. The glenoid implant is anchored to the bone with 4 screws and is for non-cemented fixation.

When during the primary surgery the glenoid stock appears to be insufficient to bear the reversed glenoid components or when glenoid bone fracture occurs during the surgical procedures, the hemi-prosthesis adaptor and the union screw can be adapted to the humeral components in order to transform the Aequalis Reversed prosthesis into a non reversed hemi-prosthesis.

When, in case of revision of an Aequalis Reversed prosthesis, the glenoid bone stock appears to be insufficient to again implant a base plate and a sphere of Aequalis Reversed range, the use of the hemi-prosthesis adaptor and the union screw allows for the transformation of the Aequalis Reversed prosthesis in to a non reversed hemi-prosthesis in order to avoid the revision of the humeral components.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K100142: Aequalis Reversed Shoulder Prosthesis.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K100142

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026