510(k) Report

510(k) · Cleared

Cleared

NDS Surgical Imaging, LLC for the Zerowire Duo Wireless HD Video Transfer System, Model WU-WX-WY (Where U=R or T, W=P, X

K100195510(k) TraditionalCleared Apr 21, 201089-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Nds Surgical Imaging · GCJ Laparoscope, General & Plastic Surgery

Cleared on Apr 21, 2010 as substantially equivalent to K081995 (Stryker Endoscopy, 2008) after an 89-day review. Its family tree reaches back 1 generation to 2008. 7 later devices descend from it.

Decided
Apr 21, 2010
Review
89 days
Class
Class II
Product code
GCJ
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K081995 (2008). 7 later devices descend from it, 3 citing it directly.

Descendants, by year cleared 2013: 1 descendant cleared2012: 2 descendants cleared2015: 1 descendant cleared2016: 1 descendant cleared2017: 1 descendant cleared2022: 1 descendant clearedK081995 · Stryker Vision Elect Whdtv (Stryker VE Whdtv) · Stryker Endoscopy · 200820052010201520202025
Descendants, by generation 1 generation forward: 3 descendants2 generations forward: 1 descendant3 generations forward: 3 descendants K081995 · Stryker Vision Elect Whdtv (Stryker VE Whdtv) · Stryker Endoscopy · 20080
  1. Root · 1 generation backK081995 Stryker Vision Elect Whdtv (Stryker VE Whdtv)Stryker Endoscopy · 2008
  2. This deviceK100195 NDS Surgical Imaging, LLC for the Zerowire Duo Wireless HD Video…Nds Surgical Imaging · 2010
  3. Descendant · cites it directly · 4 of its ownK112621 WIS1000Foreseeson Custom Displays, Inc. · 2012
  4. Descendant · 2 generations on · 3 of its ownK151609 ZeroWire Duo Wireless HD Video Transfer System G2 or ZeroWire G2Nds Surgical Imaging, LLC · 2015
  5. Descendant · 3 generations on · 2 of its ownK161228 Radiance Ultra Series ZeroWire EmbeddedNds Surgical Imaging, LLC · 2016
  6. Descendant · 3 generations on · 0 of its ownK222890 Radiance Ultra 32 4K Zerowire DuoNds Surgical Imaging, LLC · 2022
  7. Descendant · 3 generations on · 0 of its ownK170598 ZeroWire MobileNds Surgical Imaging, LLC · 2017

Showing 5 of 7 descendants. See all descendants

Descendants cleared per year

2012: 22013: 12015: 12016: 12017: 12022: 1
2012high 2 (2012) · low 0 (2014)2026

Most influential descendants

Showing 5 of 7 · See all
  • K112621WIS1000Foreseeson Custom Displays, Inc. · 2012 · cites it directly4descendants
  • K151609ZeroWire Duo Wireless HD Video Transfer System G2 or ZeroWire G2Nds Surgical Imaging, LLC · 2015 · 2 generations on3descendants
  • K161228Radiance Ultra Series ZeroWire EmbeddedNds Surgical Imaging, LLC · 2016 · 3 generations on2descendants
  • K222890Radiance Ultra 32 4K Zerowire DuoNds Surgical Imaging, LLC · 2022 · 3 generations on0descendants
  • K170598ZeroWire MobileNds Surgical Imaging, LLC · 2017 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K081995Stryker Vision Elect Whdtv (Stryker VE Whdtv)Stryker Endoscopy2008—
0 (this device)K100195NDS Surgical Imaging, LLC for the Zerowire Duo Wireless HD Video Transfer…Nds Surgical Imaging2010—
+1K112621WIS1000Foreseeson Custom Displays, Inc.2012—
+2K151609ZeroWire Duo Wireless HD Video Transfer System G2 or ZeroWire G2Nds Surgical Imaging, LLC2015—
+3K161228Radiance Ultra Series ZeroWire EmbeddedNds Surgical Imaging, LLC2016—
+3K222890Radiance Ultra 32 4K Zerowire DuoNds Surgical Imaging, LLC2022—
+3K170598ZeroWire MobileNds Surgical Imaging, LLC2017—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201220
201310
201510
201610
201710
202210
FIG. 1 — Lineage of K100195, 2008–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GCJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GCJ device

  1. #1 K214046 780 nm 1688 4K Camera System, 780 nm L11 LED…score 21.4 · 21 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K081995Stryker Vision Elect Whdtv (Stryker VE Whdtv)
Summary page 1
…al Equivalence: Stryker Vision Elect Wireless High Definition Television (Stryker VE VHDTV) I K08 1995 Both the Stryker device and the NDS device contain a wireless, radio fr…
Stryker Endoscopy2008—

Also cleared against K081995: 2 other devices →

What descends from it? (7)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K112621WIS1000Foreseeson Custom Displays, Inc.20124
K131115Zerowire Duo Wireless HD Video Transfer System, or Zero WireNds Surgical Imaging20130
K120278Wireless Image Transmitter UnitOlympus Medical Systems Corp.20120

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K112621 (Foreseeson Custom Displays, Inc., 2012) has gone furthest, with 4 descendants of its own.
  • 2 other devices also cite its predicate K081995.

How does its category compare?

All GCJ devices

GCJ Laparoscope, General & Plastic Surgery: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · GCJ

21in 2025

2007: 182008: 192009: 212010: 242011: 152012: 172013: 152014: 192015: 262016: 272017: 202018: 212019: 152020: 282021: 182022: 202023: 312024: 292025: 212026 (partial year): 26
2007high 31 (2023) · low 15 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GCJ

108in 2025

2007: 42 days median2008: 73 days median2009: 85 days median2010: 122 days median2011: 113 days median2012: 88 days median2013: 93 days median2014: 90 days median2015: 76 days median2016: 99 days median2017: 77 days median2018: 88 days median2019: 60 days median2020: 61 days median2021: 116 days median2022: 103 days median2023: 109 days median2024: 90 days median2025: 108 days median2026 (partial year): 122 days median
2007high 122 (2010) · low 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GCJ

5in 2025

2007: 122008: 162009: 62010: 302011: 92012: 12013: 7, 1 Class I2014: 22016: 52017: 12018: 12022: 12023: 12025: 52026 (partial year): 1
2007high 30 (2010) · low 0 (2015)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · GCJ

5,860in 2025

2007: 1,6392008: 1,3192009: 1,9952010: 2,6572011: 2,1332012: 1,5262013: 1,5652014: 1,7142015: 1,7102016: 2,0802017: 3,4682018: 2,5622019: 2,5782020: 2,6182021: 3,4312022: 3,9452023: 6,0022024: 6,0472025: 5,860
2007high 6,047 (2024) · low 1,319 (2008)2025

MAUDE reports naming product code GCJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071842121,639
20081973161,319
2009218561,995
201024122302,657
20111511392,133
2012178811,526
201315937 (1)1,565
2014199021,714
2015267601,710
2016279952,080
2017207713,468
2018218812,562
2019156002,578
2020286102,618
20211811603,431
20222010313,945
20233110916,002
2024299006,047
20252110855,860
2026261221—

What is it indicated for?

The NDSsi ZeroWire Duo Wireless RD Video Transfer System is a paired transmitter and receiver, intended for delivery of video signals over a radio-frequency link to a video display during endoscopic and general surgical procedures. The ZeroWire wireless device is a non-sterile reusable device not intended for use in the sterile field. It is intended for use by qualified physicians having complete knowledge of these surgical procedures.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K100195: NDS Surgical Imaging, LLC for the Zerowire Duo Wireless HD Video Transfer System, Model WU-WX-WY (Where U=R or T, W=P, X.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K100195

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026