# K100214: Cornerstone PSR Cervical Interbody Fusion Device

- Pathway: 510(k) (Traditional)
- Applicant: Medtronic Sofamor Danek
- Decided: Jun 25, 2010 after 151 days
- Product code: ODP (Intervertebral Fusion Device With Bone Graft, Cervical)
- Device class: 2
- Regulation: 21 CFR 888.3080
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 12 generations back to K003155 (2001). 65 ancestors in all.
389 later devices descend from it; 11 cite it directly.
1 of 455 devices in its family (counting itself) has a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K073285: Peek Prevail Cervical Interbody Device, Medtronic Sofamor Danek USA, Inc. (2008) Summary page 2.
- P000028: Affinity (TM) Cage System, Medtronic Sofamor Danek USA, Inc. (2002) Summary page 2.
- P980048: Bak/Cervical (Bak/C) Interbody Fusion System, Sulzer Spine-Tech (2001) Summary page 2.
- K091088: LDR Spine Cervical Interbody Fusion System, Ldr Spine USA (2009) Summary page 2.
- K092336: C-Thru Spinal System, Ebi, L.P. (2009) Summary page 2.
- K041197: Modification to Verte-Stack Spinal System, Medtronic Sofamor Danek (2004) Summary page 2.

## Most influential descendants
- K111264: Cornerstone (R) PSR Cervical Fusion System (2011), 331 descendants of its own
- K112444: Anatomic Peek Cervical Fusion System (2011), 324 descendants of its own
- K122037: Anatomic Peek Cervical Fusion System Cornerstone PSR Cervical Fusion System Peek Prevail Cervical Interbody Device Capst (2013), 281 descendants of its own
- K150135: DIVERGENCE-L Anterior/Oblique Lumbar Fusion System (2015), 228 descendants of its own
- K152277: PIVOX (tm) Oblique Lateral Spinal System (2015), 190 descendants of its own

## Indications for use
The CORNERSTONE® PSR device is indicated for cervical interbody fusion procedures in skeletally mature patients with cervical disc disease at one level from the C2-C3 disc to the C7-T1 disc. Cervical disc disease is defined as intractable radiculopathy and/or myelopathy with herniated disc and/or osteophyte formation on posterior vertebral endplates producing symptomatic nerve root and/or spinal cord compression confirmed by radiographic studies. This device is to be used in patients who have had six weeks of non-operative treatment. The CORNERSTONE® PSR device is to be used with supplemental fixation. The CORNERSTONE® PSR device is also required to be used with autograft and is to be implanted via an open, anterior approach.