510(k) Report

510(k) · Cleared

Recalled · Class II · 2022

Dimension Vista Loci CA 15-3 Flex Reagent Cartridge, Dimension Vista Loci 7 Calibrator, Models: K6456 and KC605

K100344510(k) TraditionalCleared Apr 18, 2011437-day reviewClass II21 CFR 866.6010Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Siemens Healthcare Diagnostics · MOI System, Test, Immunological, Antigen, Tumor

Cleared on Apr 18, 2011 as substantially equivalent to K012357 (Bayer Diagnostics Corp., 2002) and 1 other predicate after a 437-day review. Its family tree reaches back 3 generations to 1997. 1 later device descends from it. It has been recalled once.

Decided
Apr 18, 2011
Review
437 days
Class
Class II
Product code
MOI
Recalls
1
Predicates
2

Its longest line of descent runs back 3 generations to K963926 (1997). 5 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2002: 1 other ancestor1997: 1 other ancestor2012: 1 descendant clearedK963926 · Axsym CA 15-3 · Abbott Laboratories · 1997 · recalledK033036 · BR Monitor and BR Monitor Calibrators on the Access Immunoassay Systems, Model 387620, 387647 · Beckman Coulter, Inc. · 2004 · recalledK072612 · Access Immunoassay Systems BR Monitor, and Calibrators, Model (S) 387620,and 387647 · Beckman Coulter, Inc. · 2007 · recalled1995200020052010201520202025
  1. Root · 3 generations backK963926 Axsym CA 15-3Abbott Laboratories · 1997 · Recalled
  2. 2 generations backK033036 BR Monitor and BR Monitor Calibrators on the Access Immunoassay…Beckman Coulter, Inc. · 2004 · Recalled
  3. 1 generation backK072612 Access Immunoassay Systems BR Monitor, and Calibrators, Model (S)…Beckman Coulter, Inc. · 2007 · Recalled
  4. This deviceK100344 Dimension Vista Loci CA 15-3 Flex Reagent Cartridge, Dimension Vista…Siemens Healthcare Diagnostics · 2011
  5. Descendant · cites it directly · 0 of its ownK122398 Rapidpoint 500 System Measurement Cartridge with CalibratorsSiemens Healthcare Diagnostics, Inc. · 2012 · Recalled

Most influential descendants

Showing 1 of 1 · See all
  • K122398Rapidpoint 500 System Measurement Cartridge with CalibratorsSiemens Healthcare Diagnostics, Inc. · 2012 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K963926Axsym CA 15-3Abbott Laboratories19974
−2K033036BR Monitor and BR Monitor Calibrators on the Access Immunoassay Systems, Model…Beckman Coulter, Inc.20041
−1K072612Access Immunoassay Systems BR Monitor, and Calibrators, Model (S) 387620,and…Beckman Coulter, Inc.20071
0 (this device)K100344Dimension Vista Loci CA 15-3 Flex Reagent Cartridge, Dimension Vista Loci 7…Siemens Healthcare Diagnostics2011—
+1K122398Rapidpoint 500 System Measurement Cartridge with CalibratorsSiemens Healthcare Diagnostics, Inc.20124

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710
200210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201210
FIG. 1 — Lineage of K100344, 1997–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MOI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MOI device

  1. #1 K240403 Access BR Monitorscore 7.9 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K012357CA 15-3 Assay for the Advia Centaur System
Summary page 1
…device used to demonstrate substantial equivalence to the [OCI CA 15-3 Flex® Reagent Cartridge isthe CA 15-3 Assay for the AD VIA Centaur System previously cleared under K01 2357. The predicate device used to demonstrate substantial equivalence to the Dimension Vista® [OCI 7 Calibrator is the Calibrator fo…
Bayer Diagnostics Corp.2002—
*K072612Access Immunoassay Systems BR Monitor, and Calibrators, Model (S) 387620,and 387647
Summary page 1
…device used to demonstrate substantial equivalence to the Dimension Vista® [OCI 7 Calibrator is the Calibrator for the Access® BR Monitor Assay previously cleared under K072612. G. Device Description: The LOCI CA 15-3 (CA 15-3) method is a homogeneous, sandwich chemiluminescont immunoassa…
Beckman Coulter, Inc.20071

Also cleared against K012357: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K122398Rapidpoint 500 System Measurement Cartridge with CalibratorsSiemens Healthcare Diagnostics, Inc.20120

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jul 18, 2022Class IIZ-1648-2022Under Investigation by firmNegative bias with patient samples. The mean patient sample bias range from -26% to -33%,potential risk of delay in appropriate treatment and management decisions.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 3 companies; a new generation was cleared every 3.7 years on median.
  • 3 of the 5 ancestors have a recall of any class.
  • Of its descendants, K122398 (Siemens Healthcare Diagnostics, Inc., 2012) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K012357.

How does its category compare?

All MOI devices

MOI System, Test, Immunological, Antigen, Tumor: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · MOI

2in 2024

2007: 12011: 12018: 22019: 12020: 22024: 2
2007high 2 (2018) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MOI

Too few MOI 510(k)s in any year since 2007 to give a median.

Recalls per year · MOI

2in 2012

2007: 12012: 2
2007high 2 (2012) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MOI

6in 2025

2007: 22008: 32009: 32010: 222011: 32012: 42013: 32014: 522015: 282016: 52017: 72018: 12019: 52020: 112021: 162022: 162023: 62024: 52025: 6
2007high 52 (2014) · low 1 (2018)2025

MAUDE reports naming product code MOI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—12
20080—03
20090—03
20100—022
20111—03
20120—24
20130—03
20140—052
20150—028
20160—05
20170—07
20182—01
20191—05
20202—011
20210—016
20220—016
20230—06
20242—05
20250—06
20260—0—

What is it indicated for?

The LOCI CA 15-3 method is an in vitro diagnostic test for the quantitative measurement of CA 15-3 in human serum and lithium heparin and EDTA plasma on the Dimension Vista® System. When used in conjunction with other clinical and diagnostic procedures, serial testing with the LOCI CA 15-3 assay may be used as an aid in the management of previously treated stage II and III breast cancer patients and for monitoring response to therapy in metastatic breast cancer patients.

The LOCI 7 CAL is an in vitro diagnostic product for the calibration of Cancer Antigen 15-3 (CA 15-3) and Cancer Antigen 19-9 (CA 19-9) methods on the Dimension Vista® system.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K100344: Dimension Vista Loci CA 15-3 Flex Reagent Cartridge, Dimension Vista Loci 7 Calibrator, Models: K6456 and KC605.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K100344

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026