510(k) Report

510(k) · Cleared

Cleared

Compressible Limb Therapy System Model WHF-324 (Power-Q1000 Plus)

K100656510(k) SpecialCleared May 26, 201079-day reviewClass II21 CFR 890.5650

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Wonjin Mulsan Co., Ltd. · IRP Massager, Powered Inflatable Tube

Cleared on May 26, 2010 as substantially equivalent to K080134 (Wonjin Mulsan Co., Ltd., 2009) after a 79-day review. Its family tree reaches back 3 generations to 1992. 13 later devices descend from it.

Decided
May 26, 2010
Review
79 days
Class
Class II
Product code
IRP
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K914774 (1992). 4 ancestors in all, the oldest K915638 (1992). 13 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1992: 1 other ancestor2011: 2 descendants cleared2012: 3 descendants cleared2017: 2 descendants cleared2020: 1 descendant cleared2015: 1 descendant cleared2021: 1 descendant cleared2025: 1 descendant cleared2023: 1 descendant cleared2019: 1 descendant clearedK914774 · Multipulse Sequential Compression Unit · Talley Group, Ltd. · 1992K013061 · Biotouch Massage Therapy System · Tactile Systems Technology, Inc. · 2002K080134 · Compressible Limb and Circulation Therapy System, Model WHF-314 (Power-Q1000) · Wonjin Mulsan Co., Ltd. · 20091990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor 1 generation forward: 3 descendants2 generations forward: 7 descendants3 generations forward: 3 descendants K080134 · Compressible Limb and Circulation Therapy System, Model WHF-314 (Power-Q1000) · Wonjin Mulsan Co., Ltd. · 2009K013061 · Biotouch Massage Therapy System · Tactile Systems Technology, Inc. · 2002K914774 · Multipulse Sequential Compression Unit · Talley Group, Ltd. · 19920
  1. Root · 3 generations backK914774 Multipulse Sequential Compression UnitTalley Group, Ltd. · 1992
  2. 2 generations backK013061 Biotouch Massage Therapy SystemTactile Systems Technology, Inc. · 2002
  3. 1 generation backK080134 Compressible Limb and Circulation Therapy System, Model WHF-314…Wonjin Mulsan Co., Ltd. · 2009
  4. This deviceK100656 Compressible Limb Therapy System Model WHF-324 (Power-Q1000 Plus)Wonjin Mulsan Co., Ltd. · 2010
  5. Descendant · cites it directly · 6 of its ownK102320 Compressible Limb and Circulation Therapy System Model LX7(V7)Daesung Maref Co., Ltd. · 2011
  6. Descendant · cites it directly · 3 of its ownK113275 Compressible Limb Therapy SystemWonjin Mulsan Co., Ltd. · 2012
  7. Descendant · cites it directly · 3 of its ownK102319 Compressible Limb and Circulation Therapy System Model Wic-2008Won Industrial Co. · 2011
  8. Descendant · 2 generations on · 1 of its ownK161907 Pressure Therapy SystemXiamen Senyang Co., Ltd. · 2017
  9. Descendant · 2 generations on · 1 of its ownK150033 Air Compressible Limb Therapy SystemDaesung Maref Co., Ltd. · 2015

Showing 5 of 13 descendants. See all descendants

Descendants cleared per year

2011: 22012: 32015: 12017: 22019: 12020: 12021: 12023: 12025: 1
2011high 3 (2012) · low 0 (2013)2026

Most influential descendants

Showing 5 of 13 · See all
  • K102320Compressible Limb and Circulation Therapy System Model LX7(V7)Daesung Maref Co., Ltd. · 2011 · cites it directly6descendants
  • K113275Compressible Limb Therapy SystemWonjin Mulsan Co., Ltd. · 2012 · cites it directly3descendants
  • K102319Compressible Limb and Circulation Therapy System Model Wic-2008Won Industrial Co. · 2011 · cites it directly3descendants
  • K161907Pressure Therapy SystemXiamen Senyang Co., Ltd. · 2017 · 2 generations on1descendant
  • K150033Air Compressible Limb Therapy SystemDaesung Maref Co., Ltd. · 2015 · 2 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K914774Multipulse Sequential Compression UnitTalley Group, Ltd.1992—
−2K013061Biotouch Massage Therapy SystemTactile Systems Technology, Inc.2002—
−1K080134Compressible Limb and Circulation Therapy System, Model WHF-314 (Power-Q1000)Wonjin Mulsan Co., Ltd.2009—
0 (this device)K100656Compressible Limb Therapy System Model WHF-324 (Power-Q1000 Plus)Wonjin Mulsan Co., Ltd.2010—
+1K102320Compressible Limb and Circulation Therapy System Model LX7(V7)Daesung Maref Co., Ltd.2011—
+1K113275Compressible Limb Therapy SystemWonjin Mulsan Co., Ltd.2012—
+1K102319Compressible Limb and Circulation Therapy System Model Wic-2008Won Industrial Co.2011—
+2K161907Pressure Therapy SystemXiamen Senyang Co., Ltd.2017—
+2K150033Air Compressible Limb Therapy SystemDaesung Maref Co., Ltd.2015—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201120
201230
201510
201720
201910
202010
202110
202310
202510
FIG. 1 — Lineage of K100656, 1992–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IRP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IRP device

  1. #1 K193354 Air Compression Therapy Devicescore 28.6 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K080134Compressible Limb and Circulation Therapy System, Model WHF-314 (Power-Q1000)
Summary page 1
…setting. Power unit features visual operation statusand fault indicators. G. Substantial Equivalence Information 1.Predicate Device - 510(k) number: K080134 - Name: Compressible Limb and Circulation Therapy Systems (WHF-314 (POWER-Qi1000)) - Classification: 2…
Wonjin Mulsan Co., Ltd.2009—

What descends from it? (13)

See all 13

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K102320Compressible Limb and Circulation Therapy System Model LX7(V7)Daesung Maref Co., Ltd.20116
K113275Compressible Limb Therapy SystemWonjin Mulsan Co., Ltd.20123
K102319Compressible Limb and Circulation Therapy System Model Wic-2008Won Industrial Co.20113

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 3 companies; a new generation was cleared every 6.6 years on median.
  • None of the 4 ancestors has a recall.
  • Of its descendants, K102320 (Daesung Maref Co., Ltd., 2011) has gone furthest, with 6 descendants of its own.

How does its category compare?

All IRP devices

IRP Massager, Powered Inflatable Tube: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · IRP

13in 2025

2007: 22008: 12009: 12010: 22011: 32012: 52013: 22014: 42015: 22016: 12017: 42018: 32019: 102020: 92021: 192022: 142023: 102024: 122025: 132026 (partial year): 12
2007high 19 (2021) · low 1 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IRP

141in 2025

2011: 164 days median2012: 116 days median2014: 113 days median2017: 170 days median2018: 80 days median2019: 83 days median2020: 150 days median2021: 140 days median2022: 97 days median2023: 143 days median2024: 115 days median2025: 141 days median2026 (partial year): 172 days median
2007high 172 (2026) · low 80 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IRP

2in 2017

2011: 12017: 2
2007high 2 (2017) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IRP

10in 2025

2008: 22009: 12010: 52011: 32012: 32015: 32016: 22020: 12022: 12024: 42025: 10
2007high 10 (2025) · low 0 (2007)2025

MAUDE reports naming product code IRP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
20081—02
20091—01
20102—05
2011316413
2012511603
20132—00
2014411300
20152—03
20161—02
2017417020
201838000
2019108300
2020915001
20211914000
2022149701
20231014300
20241211504
202513141010
2026121720—

What is it indicated for?

WHF-324 (POWER-Q1000 PLUS) is intended for use by medical professionals and patients at home, who are under medical supervision, in treating many conditions, such as: Primary lymphedema, Edema following trauma and sport injuries, Postimmobilization edema, Venous insufficiencies, Lymphedema.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K100656: Compressible Limb Therapy System Model WHF-324 (Power-Q1000 Plus).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K100656

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026