510(k) Report

510(k) · Cleared

Cleared

Pta-Plus Pta Balloon Cather 5 MM X 4CM, Pta-Plus Pta Balloon Catheter 6MM X 4CM

K100842510(k) TraditionalCleared Jul 12, 2010109-day reviewClass II21 CFR 870.5150

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Hotspur Technologies · DXE Catheter, Embolectomy

Cleared on Jul 12, 2010 as substantially equivalent to K901625 (Baxter Healthcare Corp, 1990) and 1 other predicate after a 109-day review. Its family tree reaches back 2 generations to 2002. 2 later devices descend from it.

Decided
Jul 12, 2010
Review
109 days
Class
Class II
Product code
DXE
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K014212 (2002). 3 ancestors in all, the oldest K901625 (1990). 2 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1990: 1 other ancestor2023: 1 descendant cleared2025: 1 descendant clearedK014212 · Bard Conquest Pta Balloon Dilatation Catheter · C.R. Bard, Inc. · 2002K073472 · Vaccess Pta Balloon Dilatation Catheter · C.R. Bard, Inc. · 2008 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 1 descendant2 generations forward: 1 descendant K073472 · Vaccess Pta Balloon Dilatation Catheter · C.R. Bard, Inc. · 2008 · recalledK014212 · Bard Conquest Pta Balloon Dilatation Catheter · C.R. Bard, Inc. · 20020
  1. Root · 2 generations backK014212 Bard Conquest Pta Balloon Dilatation CatheterC.R. Bard, Inc. · 2002
  2. 1 generation backK073472 Vaccess Pta Balloon Dilatation CatheterC.R. Bard, Inc. · 2008 · Recalled
  3. This deviceK100842 Pta-Plus Pta Balloon Cather 5 MM X 4CM, Pta-Plus Pta Balloon…Hotspur Technologies · 2010
  4. Descendant · cites it directly · 1 of its ownK223613 InThrill Thrombectomy SystemInari Medical, Inc. · 2023
  5. Descendant · 2 generations on · 0 of its ownK250421 InThrill™ Thrombectomy SystemInari Medical, Inc. · 2025

Most influential descendants

Showing 2 of 2 · See all
  • K223613InThrill Thrombectomy SystemInari Medical, Inc. · 2023 · cites it directly1descendant
  • K250421InThrill™ Thrombectomy SystemInari Medical, Inc. · 2025 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K014212Bard Conquest Pta Balloon Dilatation CatheterC.R. Bard, Inc.2002—
−1K073472Vaccess Pta Balloon Dilatation CatheterC.R. Bard, Inc.20081
0 (this device)K100842Pta-Plus Pta Balloon Cather 5 MM X 4CM, Pta-Plus Pta Balloon Catheter 6MM X 4CMHotspur Technologies2010—
+1K223613InThrill Thrombectomy SystemInari Medical, Inc.2023—
+2K250421InThrill™ Thrombectomy SystemInari Medical, Inc.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202310
202510
FIG. 1 — Lineage of K100842, 2002–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXE device

  1. #1 K240078 Fogarty Thru-Lumen Embolectomy Catheterscore 7.9 · 1 generation · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K901625Fogarty Arterial Embolectomy II Catheter
Summary page 1
…ctomy (21 CFR 870.5150, Product Code DXE) C. Predicate Device Name(s): Trade Name(s): Edwards Fogarty Adherent Clot Catheter, K901625 BARD Vaccess PTA Balloon Dilation Catheter, K073472 D. Device Descript…
Baxter Healthcare Corp19901
*K073472Vaccess Pta Balloon Dilatation Catheter
Summary page 1
…Edwards Fogarty Adherent Clot Catheter, K901625 BARD Vaccess PTA Balloon Dilation Catheter, K073472 D. Device Description: The proposed PTA-Plus PTA Balloon Catheter is designed for de-clotting and treating stenosis…
C.R. Bard, Inc.20081

Also cleared against K901625: 1 other device →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K223613InThrill Thrombectomy SystemInari Medical, Inc.20231

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 8 years and passes through 2 companies; a new generation was cleared every 6.0 years on median.
  • 2 of the 3 ancestors have a recall of any class.
  • Of its descendants, K223613 (Inari Medical, Inc., 2023) has gone furthest, with 1 descendant of its own.
  • 1 other device also cites its predicate K901625.

How does its category compare?

All DXE devices

DXE Catheter, Embolectomy: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · DXE

5in 2024

2008: 12010: 22015: 12017: 22020: 12021: 12022: 12024: 5
2007high 5 (2024) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXE

173in 2024

2024: 173 days median
2007high 173 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXE

1in 2023

2007: 32009: 52010: 12011: 12015: 132021: 4, 4 Class I2022: 32023: 12026 (partial year): 2
2007high 13 (2015) · low 0 (2008)2026

Class I (4 since 2007) Class II/III not classified

Adverse event reports per year · DXE

306in 2025

2007: 1672008: 1342009: 1242010: 1362011: 1642012: 2002013: 1502014: 1922015: 2662016: 7962017: 7702018: 6152019: 5942020: 5472021: 3332022: 4632023: 4362024: 3772025: 306
2007high 796 (2016) · low 124 (2009)2025

MAUDE reports naming product code DXE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—3167
20081—0134
20090—5124
20102—1136
20110—1164
20120—0200
20130—0150
20140—0192
20151—13266
20160—0796
20172—0770
20180—0615
20190—0594
20201—0547
20211—4 (4)333
20221—3463
20230—1436
202451730377
20250—0306
20260—2—

What is it indicated for?

The PTA-Plus PTA Balloon Catheter is indicated for use within synthetic arteriovenous dialysis fistulae to remove embolic material (thrombus/debris) and dilate stenosis for treatment of obstructive lesions.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K100842: Pta-Plus Pta Balloon Cather 5 MM X 4CM, Pta-Plus Pta Balloon Catheter 6MM X 4CM.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K100842

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026