# K101153: Quadrox-ID Adult Diffusion Membrane Oxygenator with Softline Coating, Model: BE-Hmod 70000-Usa, Beq-Hmod 70000-Usa, Hmod

- Pathway: 510(k) (Traditional)
- Applicant: Maquet Cardiopulmonary, AG
- Decided: Dec 8, 2010 after 229 days
- Product code: DTZ (Oxygenator, Cardiopulmonary Bypass)
- Device class: 2
- Regulation: 21 CFR 870.4350
- Recalls of this device: 4 (0 Class I)
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 8 generations back to K922933 (1992). 20 ancestors in all.
6 later devices descend from it; 2 cite it directly.
0 of 27 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K082117: Quadrox-I Adult with and Without Integrated Arterial Filter with Softline Coating, Model# Hmo 70000, Hmo 71000, Maquet Cardiopulmonary, AG (2009) Summary page 1.
- K090511: Quadrox-I Adult Microporous Membrane Oxygenator with Bioline Coating, Model BEHMO70000,Beq-HMO70000, Maquet Cardiopulmonary, AG (2009) Summary page 1.

## Most influential descendants
- K132829: Quadrox-I, Quadrox-ID, Quadrox-IR Oxygenators (2013), 4 descendants of its own
- K150267: QUADROX-i Adult/Small Adult Oxygenators;QUADROX-iD Adult Oxygenators (2015), 2 descendants of its own
- K203424: Quantum Perfusion Blood Oxygenator ECC VT200-E1, Quantum Perfusion Blood Oxygenator ECC VT200-E2, Quantum Perfusion Blood Oxygenator ECC VT160-E1,  Quantum Perfusion Blood Oxygenator ECC VT160-E2 (2021), 1 descendant of its own
- K240934: Quantum Perfusion Blood Oxygenator ECC VT160-E3 (VT160-E3); Quantum Perfusion Blood Oxygenator ECC VT200-E3 (VT200-E3); Quantum Perfusion Blood Oxygenator VT75- E3 (VT75- E3); (2026), 0 descendants of its own
- K133265: Quadrox-IR Adult and Small Adult (2013), 0 descendants of its own

## Recalls of this device
- May 18, 2023 · Class II · Z-1634-2023: 1. An accessory may be improperly placed during packaging, causing creases and damage to the accessory's sterile pouch. 2. Product packaging may exhibit holes, cracks, dents, and crushed areas. Both i
- May 18, 2023 · Class II · Z-1635-2023: 1. An accessory may be improperly placed during packaging, causing creases and damage to the accessory s sterile pouch. 2. Product packaging may exhibit holes, cracks, dents, and crushed areas. Both i
- May 18, 2023 · Class II · Z-1656-2023: Product packaging may exhibit small pinholes which may not be visible to the unaided eye, compromising the sterile barrier of the packaging. Exposure to non-sterile device may result in inflammation, 
- Feb 23, 2016 · Class II · Z-1371-2016: Maquet Cardiopulmonary (MCP) is conducting a voluntary recall based on the potential risk of exposure to endotoxin for various products.

## Indications for use
The QUADROX-ID Adult diffusion membrane oxygenator is intended for use in an extracorporeal circulation during cardiopulmonary bypass in cardiac surgery. Within the specified flow rate range, the device oxygenates the blood, removes carbon dioxide from the blood and regulates the blood temperature. The application duration is limited to 6 hours. Responsibility for deciding whether to use an oxygenator rests solely with the attending physician.

Source page: https://510kreport.com/device/K101153