Tempus IC Professional Patient Monitor

K101264510(k) TraditionalCleared May 11, 20106-day reviewClass II21 CFR 870.2300Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Remote Diagnostic Technologies, Ltd. · MWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)

Cleared on May 11, 2010 as substantially equivalent to K921497 (Protocol Systems, Inc., 1993) and 4 other predicates after a 6-day review. Its family tree reaches back 1 generation to 1991. 16 later devices descend from it. It has been recalled once.

Decided
May 11, 2010
Review
6 days
Class
Class II
Product code
MWI
Recalls
1
Predicates
6

Its longest line of descent runs back 1 generation to K910772 (1991). 5 ancestors in all. 16 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2001: 1 other ancestor1993: 1 other ancestor1992: 1 other ancestor1991: 1 other ancestor2013: 1 descendant cleared2011: 1 descendant cleared2015: 1 descendant cleared2014: 3 descendants cleared2017: 2 descendants cleared2016: 1 descendant cleared2018: 1 descendant cleared2020: 2 descendants cleared2022: 1 descendant cleared2025: 2 descendants cleared2024: 1 descendant clearedK910772 · Propaq 102, 104 and 106 · Protocol Systems, Inc. · 19911990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 4 other ancestors 1 generation forward: 2 descendants2 generations forward: 5 descendants3 generations forward: 2 descendants4 generations forward: 2 descendants5 generations forward: 1 descendant6 generations forward: 1 descendant7 generations forward: 2 descendants8 generations forward: 1 descendant K910772 · Propaq 102, 104 and 106 · Protocol Systems, Inc. · 19910+5
  1. Root · 1 generation backK910772 Propaq 102, 104 and 106Protocol Systems, Inc. · 1991
  2. This deviceK101264 Tempus IC Professional Patient MonitorRemote Diagnostic Technologies, Ltd. · 2010
  3. Descendant · cites it directly · 8 of its ownK113105 Tempusic Patient MonitorRemote Diagnostic Technologies, Ltd. · 2011
  4. Descendant · 2 generations on · 7 of its ownK152124 Tempus IC2Remote Diagnostics Technologies, Ltd. · 2015
  5. Descendant · 3 generations on · 6 of its ownK152645 Dictum HealthDictum Health, Inc. · 2016
  6. Descendant · cites it directly · 6 of its ownK130773 Tempus Pro Patient MonitorRemote Diagnostic Technologies, Ltd. · 2013 · Recalled
  7. Descendant · 4 generations on · 5 of its ownK170798 Dictum HealthDictum Health, Inc. · 2017

Showing 5 of 16 descendants. See all descendants

Descendants cleared per year

2011: 12013: 12014: 32015: 12016: 12017: 22018: 12020: 22022: 12024: 12025: 2
2011high 3 (2014) · low 0 (2012)2026

Most influential descendants

Showing 5 of 16 · See all
  • K113105Tempusic Patient MonitorRemote Diagnostic Technologies, Ltd. · 2011 · cites it directly8descendants
  • K152124Tempus IC2Remote Diagnostics Technologies, Ltd. · 2015 · 2 generations on7descendants
  • K152645Dictum HealthDictum Health, Inc. · 2016 · 3 generations on6descendants
  • K130773Tempus Pro Patient MonitorRemote Diagnostic Technologies, Ltd. · 2013 · cites it directly6descendants
  • K170798Dictum HealthDictum Health, Inc. · 2017 · 4 generations on5descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K910772Propaq 102, 104 and 106Protocol Systems, Inc.1991—
0 (this device)K101264Tempus IC Professional Patient MonitorRemote Diagnostic Technologies, Ltd.2010—
+1K113105Tempusic Patient MonitorRemote Diagnostic Technologies, Ltd.2011—
+2K152124Tempus IC2Remote Diagnostics Technologies, Ltd.2015—
+3K152645Dictum HealthDictum Health, Inc.2016—
+1K130773Tempus Pro Patient MonitorRemote Diagnostic Technologies, Ltd.20131
+4K170798Dictum HealthDictum Health, Inc.2017—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199210
199310
200110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201310
201430
201510
201610
201720
201810
202020
202210
202410
202520
FIG. 1 — Lineage of K101264, 1991–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MWI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MWI device

  1. #1 K230457 Empatica Health Monitoring Platform…score 28.0 · 39 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (6)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.

TypeNumberDeviceApplicantDecidedRecalls
Kept off the family treeK082715FDA’s K082715 is Depuy Global AP Cta Humeral Head
Our reading of the summary gave K082715, FDA’s number for Depuy Global AP Cta Humeral Head (DePuy Orthopaedics, Inc.). Its FDA name has none of the distinctive words the summary uses for the device it names, “Tempus IC Patient Monitor”. Kept off the family tree.
Summary page 2
…e Devices The Tempus IC Professional Patient Monitor is predicated on our existing model, the Tempus IC Patient Monitor, which was the subject of a previous submissions (K082715), and is being cited as the predicate for this new finished device (in addition to other predicates most notably the Propaq 102 w…
DePuy Orthopaedics, Inc.2008—
*K921497Propaq Monitors, Modification
Summary page 2
…missions (K082715), and is being cited as the predicate for this new finished device (in addition to other predicates most notably the Propaq 102 which was cleared under K921497, K914838, K910882 and K910772). The Tempus IC Professional Patient Monitor is the same hardware as the predicate (excepting a rev…
Protocol Systems, Inc.1993—
*K914838Propaq 102,104,106,102EL,104EL,&106EL
Summary page 2
…(K082715), and is being cited as the predicate for this new finished device (in addition to other predicates most notably the Propaq 102 which was cleared under K921497, K914838, K910882 and K910772). The Tempus IC Professional Patient Monitor is the same hardware as the predicate (excepting a revised memb…
Protocol Systems, Inc.1992—
*K910882Propaq 102EL, 104EL and 106EL
Summary page 2
…, and is being cited as the predicate for this new finished device (in addition to other predicates most notably the Propaq 102 which was cleared under K921497, K914838, K910882 and K910772). The Tempus IC Professional Patient Monitor is the same hardware as the predicate (excepting a revised membrane keyp…
Protocol Systems, Inc.1991—
*K910772Propaq 102, 104 and 106
Summary page 2
…ng cited as the predicate for this new finished device (in addition to other predicates most notably the Propaq 102 which was cleared under K921497, K914838, K910882 and K910772). The Tempus IC Professional Patient Monitor is the same hardware as the predicate (excepting a revised membrane keypad and offer…
Protocol Systems, Inc.1991—
*K011059Infared Ear Thermometer, Model TH8 Series
Summary page 2
…ame personnel (trained healthcare professionals) for the same patients (adults and children). Lastly, the Radiant Innovations TH809 thermometer is cited as a predicate (K01 1059) for the modified version (that provides Bluetooth communications of the measured readings) that will be provided with the Tempus…
Radiant Innovation, Inc.2001—

What descends from it? (16)

See all 16

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K113105Tempusic Patient MonitorRemote Diagnostic Technologies, Ltd.20118
K130773Tempus Pro Patient MonitorRemote Diagnostic Technologies, Ltd.20136

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Mar 25, 2011Not classifiedZ-2183-2011Component change controlIt was discovered that when a 12 Lead ECG is recorded and monitoring is quickly restarted, the ECG can cease functioning.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 5 ancestors has a recall.
  • Of its descendants, K113105 (Remote Diagnostic Technologies, Ltd., 2011) has gone furthest, with 8 descendants of its own.

How does its category compare?

All MWI devices

MWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms): FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · MWI

4in 2025

2007: 92008: 92009: 62010: 172011: 112012: 132013: 202014: 162015: 192016: 122017: 132018: 112019: 142020: 82021: 92022: 52023: 82024: 102025: 42026 (partial year): 6
2007high 20 (2013) · low 4 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MWI

247in 2025

2007: 42 days median2008: 49 days median2009: 112 days median2010: 58 days median2011: 78 days median2012: 104 days median2013: 85 days median2014: 148 days median2015: 127 days median2016: 165 days median2017: 205 days median2018: 217 days median2019: 255 days median2020: 138 days median2021: 161 days median2022: 231 days median2023: 250 days median2024: 202 days median2025: 247 days median2026 (partial year): 239 days median
2007high 255 (2019) · low 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MWI

9so far in 2026, the most since 2007

2007: 12008: 12009: 22010: 22011: 32012: 52013: 32014: 62015: 12017: 22019: 42022: 22024: 52026 (partial year): 9
2007high 9 (2026) · low 0 (2016)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MWI

182in 2025

2007: 32008: 32009: 202010: 172011: 162012: 312013: 422014: 302015: 312016: 512017: 852018: 1582019: 1692020: 1102021: 1882022: 1682023: 1792024: 1202025: 182
2007high 188 (2021) · low 3 (2007)2025

MAUDE reports naming product code MWI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200794213
200894913
20096112220
20101758217
20111178316
201213104531
20132085342
201416148630
201519127131
201612165051
201713205285
2018112170158
2019142554169
202081380110
202191610188
202252312168
202382500179
2024102025120
202542470182
202662399—

What is it indicated for?

The Tempus IC Professional is a portable vital signs monitor intended to be used by clinicians and medically qualified personnel for the attended or unattended monitoring of single or multiple vital signs in clinical and pre-hospital care applications. The device is indicated for 3 Lead EGG monitoring and 12 Lead EGG recording, non-invasive blood pressure (NIBP), respiration, end-tidal C02 (ETCO 2), pulse oximetry (SPO 2 ) and tympanic temperature. The…

Read the full statement (119 words)

The Tempus IC Professional is a portable vital signs monitor intended to be used by clinicians and medically qualified personnel for the attended or unattended monitoring of single or multiple vital signs in clinical and pre-hospital care applications. The device is indicated for 3 Lead EGG monitoring and 12 Lead EGG recording, non-invasive blood pressure (NIBP), respiration, end-tidal C02 (ETCO 2), pulse oximetry (SPO 2 ) and tympanic temperature.

The monitor is intended to be used as a stand-alone monitor or as a telemedicine system (transmitting patieht data to other medical professionals located elsewhere).

The EGG Harness of the Tempus IC Professional is suitable for use on adults or children (over 10 years old and over 20kg in weight).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K101264: Tempus IC Professional Patient Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K101264

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026