510(k) Report

510(k) · Cleared

Recalled · Class I · 2026

Vasoview Hemopro 2 Endoscopic Vessel Harvesting System

K101274510(k) TraditionalCleared Jun 11, 201036-day reviewClass II21 CFR 878.4400Recalls 10 (2 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Maquet Cardiovascular, LLC · GEI Electrosurgical, Cutting & Coagulation & Accessories

Cleared on Jun 11, 2010 as substantially equivalent to K052274 (Guidant Corporation, 2005) and 1 other predicate after a 36-day review. Its family tree reaches back 5 generations to 1994. 2 of the 17 devices in its family, counting itself, have a Class I recall. 4 later devices descend from it. It has been recalled 10 times, including 2 Class I recalls.

Decided
Jun 11, 2010
Review
36 days
Class
Class II
Product code
GEI
Recalls
10 (2 Class I)
Predicates
2

Its longest line of descent runs back 5 generations to K945975 (1994). 12 ancestors in all, the oldest K904993 (1991). 4 later devices descend from it, 3 citing it directly. 2 of the 17 devices in this family, counting this one, have a Class I recall.

  1. Root · 5 generations backK945975 Evershears (R) Scissors, Bilap (R) Probes, Bicoag (R) ForcepsEverest Medical Corp. · 1994
  2. 4 generations backK020143 Vasoview 5 Harvesting CannulaGuidant Corporation, Cardiac Surgery · 2002 · Recalled
  3. 3 generations backK022718 Vasoview 6 Harvesting Cannula, Models VH-2000, VH-2001 & VH-2002Guidant Corporation, Cardiac Surgery · 2002
  4. 2 generations backK041981 Guidant Vasoview 6 Harvesting Cannula, Model VH-2000; Guidant…Guidant Corporation · 2004 · Recalled
  5. 1 generation backK052274 Guidant Vasoview Hemopro Endoscopic Vessel Harvesting System, Model…Guidant Corporation · 2005 · Recalled (Class I)
  6. This deviceK101274 Vasoview Hemopro 2 Endoscopic Vessel Harvesting SystemMaquet Cardiovascular, LLC · 2010
  7. Descendant · cites it directly · 2 of its ownK233879 Vasoview Hemopro 3 Endoscopic Vessel Harvesting System (VH-6000)…Maquet Cardiovascular, LLC · 2024
  8. Descendant · cites it directly · 0 of its ownK251238 Vasoview Hemopro 3 Endoscopic Vessel Harvesting System (VH-6000)…Maquet Cardiovascular, LLC · 2025 · Recalled
  9. Descendant · 2 generations on · 0 of its ownK243918 Vasoview Hemopro 3 Power SupplyMaquet Cardiovascular, LLC · 2025
  10. Descendant · cites it directly · 0 of its ownK191947 VASOVIEW HEMOPRO Extension Cable, VASOVIEW HEMOPRO 2 Extension…Maquet Cardiovascular, LLC · 2019

Class I recalls in this family

Most influential descendants

Showing 4 of 4 · See all
  • K233879Vasoview Hemopro 3 Endoscopic Vessel Harvesting System (VH-6000), Vasoview Hemopro 3…Maquet Cardiovascular, LLC · 2024 · cites it directly2descendants
  • K251238Vasoview Hemopro 3 Endoscopic Vessel Harvesting System (VH-6000); Vasoview Hemopro 3…Maquet Cardiovascular, LLC · 2025 · cites it directly0descendants
  • K243918Vasoview Hemopro 3 Power SupplyMaquet Cardiovascular, LLC · 2025 · 2 generations on0descendants
  • K191947VASOVIEW HEMOPRO Extension Cable, VASOVIEW HEMOPRO 2 Extension Cable, Bipolar Extension…Maquet Cardiovascular, LLC · 2019 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K945975Evershears (R) Scissors, Bilap (R) Probes, Bicoag (R) ForcepsEverest Medical Corp.1994—
−4K020143Vasoview 5 Harvesting CannulaGuidant Corporation, Cardiac Surgery20021
−3K022718Vasoview 6 Harvesting Cannula, Models VH-2000, VH-2001 & VH-2002Guidant Corporation, Cardiac Surgery2002—
−2K041981Guidant Vasoview 6 Harvesting Cannula, Model VH-2000; Guidant Vasoview 6…Guidant Corporation20042
−1K052274Guidant Vasoview Hemopro Endoscopic Vessel Harvesting System, Model VH-3000Guidant Corporation2005Class I
0 (this device)K101274Vasoview Hemopro 2 Endoscopic Vessel Harvesting SystemMaquet Cardiovascular, LLC2010—
+1K233879Vasoview Hemopro 3 Endoscopic Vessel Harvesting System (VH-6000), Vasoview…Maquet Cardiovascular, LLC2024—
+1K251238Vasoview Hemopro 3 Endoscopic Vessel Harvesting System (VH-6000); Vasoview…Maquet Cardiovascular, LLC20251
+2K243918Vasoview Hemopro 3 Power SupplyMaquet Cardiovascular, LLC2025—
+1K191947VASOVIEW HEMOPRO Extension Cable, VASOVIEW HEMOPRO 2 Extension Cable, Bipolar…Maquet Cardiovascular, LLC2019—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199610
199720
199810
199910
200310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201910
202410
202520
FIG. 1 — Lineage of K101274, 1994–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GEI device

  1. #1 K231790 The InMode System with the Morpheus8 Applicatorsscore 32.7 · 21 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K052274Guidant Vasoview Hemopro Endoscopic Vessel Harvesting System, Model VH-3000
Summary page 1
…e substantially equivalent with regard to those features in the predicate VASOVIEW HEMOPRO Endoscopic Vessel Harvesting System (K052274), and with regard to the spot cautery element in the VasoView 6 Harvesting Cannula (K(041981). Device…
Guidant Corporation2005Class I
*K041981Guidant Vasoview 6 Harvesting Cannula, Model VH-2000; Guidant Vasoview 6 Accessory Pack…
Summary page 1
…RO Endoscopic Vessel Harvesting System (K052274), and with regard to the spot cautery element in the VasoView 6 Harvesting Cannula (K(041981). Device The VASOVIEW HEMOPRO 2 Endoscopic Vessel Harvesting System is description designed for use in conjuncti…
Guidant Corporation20042

Also cleared against K052274: 2 other devices →

What descends from it? (4)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K233879Vasoview Hemopro 3 Endoscopic Vessel Harvesting System (VH-6000), Vasoview Hemopro 3…Maquet Cardiovascular, LLC20242
K251238Vasoview Hemopro 3 Endoscopic Vessel Harvesting System (VH-6000); Vasoview Hemopro 3…Maquet Cardiovascular, LLC20250
K191947VASOVIEW HEMOPRO Extension Cable, VASOVIEW HEMOPRO 2 Extension Cable, Bipolar Extension…Maquet Cardiovascular, LLC20190

Has anything in its family been recalled? (2 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 2, 2026Class IIZ-2741-2026Under Investigation by firmGetinge identified that Vasoview Hemopro 2 devices from Lot 3000547797 were exposed to an out-of-specification sterilization dose during a gamma sterilization run (Run ID 1183-28782A) performed by STERIS at its Whippany, NJ facility…
Mar 20, 2025Class IIZ-1622-2025Under Investigation by firmThere have been at least 12 complaints from users as of March 3, 2025, reporting that they identified the ceramic C-Ring to be broken in half during use of the device. The ceramic C-Ring has a potential to break while in use.…
Mar 10, 2025Class IIZ-1577-2025Under Investigation by firmIncorrect resistor utilized in the VH-3010 Power Supply, which may cause the jaws of the HemoPro 2 to not adequately heat up.
Dec 9, 2024Class IZ-0711-2025Device DesignPotential for two issues: 1. Bent or detached heater wire; 2. Silicone peeling or detaching from the Jaws of the Harvesting Tool
Dec 9, 2024Class IZ-0712-2025Device DesignPotential for two issues: 1. Bent or detached heater wire; 2. Silicone peeling or detaching from the Jaws of the Harvesting Tool
May 31, 2024Class IIZ-2338-2024Under Investigation by firmThere were 27 complaints between March 22, 2024, and April 30, 2024, related to VH-3500 and VH-4000, reporting that the C-Ring wire was straightened (due to insufficient bend radius) and that the distance between C-Ring and Harvesting…
May 17, 2024Class IIZ-2175-2024Device DesignPotential for there to be a fluid ingress into the handle of the harvesting tool, which may lead to the device not providing cautery or providing cautery when not intended.
Mar 6, 2023Class IIZ-1336-2023Process controlSome batches of product were not sterilized to their minimum sterilization specification.
Dec 22, 2022Class IIZ-0995-2023Under Investigation by firmInk on the Vasoshield syringe Maquet logo may chip resulting in an unreasonable risk of harm to the patient. Potential harms may include foreign body reaction, coronary embolic event, and peripheral embolic event.
Oct 30, 2013Class IIZ-0466-2014Component design/selectionMaquet has received an increase in the number of complaints for "self-activated/remains activated/overheats" for the Hemopro VH-30000, "Hemopro 1"

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K052274Guidant Vasoview Hemopro Endoscopic Vessel Harvesting System, Model VH-3000Guidant Corporation · 2005 · Direct predicate · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 16 years and passes through 4 companies; a new generation was cleared every 2.0 years on median.
  • 4 of the 12 ancestors have a recall of any class; 1 has a Class I recall.
  • Of its descendants, K233879 (Maquet Cardiovascular, LLC, 2024) has gone furthest, with 2 descendants of its own.
  • 2 other devices also cite its predicate K052274.

How does its category compare?

All GEI devices

GEI Electrosurgical, Cutting & Coagulation & Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · GEI

52in 2025

2007: 502008: 612009: 422010: 462011: 352012: 392013: 482014: 492015: 472016: 642017: 522018: 472019: 482020: 592021: 462022: 552023: 652024: 592025: 522026 (partial year): 43
2007high 65 (2023) · low 35 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GEI

113in 2025

2007: 51 days median2008: 71 days median2009: 130 days median2010: 109 days median2011: 135 days median2012: 133 days median2013: 136 days median2014: 103 days median2015: 123 days median2016: 108 days median2017: 72 days median2018: 93 days median2019: 93 days median2020: 105 days median2021: 146 days median2022: 150 days median2023: 104 days median2024: 125 days median2025: 113 days median2026 (partial year): 183 days median
2007high 183 (2026) · low 51 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GEI

4in 2025

2007: 212008: 192009: 272010: 512011: 322012: 302013: 132014: 32015: 42016: 32017: 22018: 62019: 52020: 12021: 62022: 492023: 27, 4 Class I2024: 22, 10 Class I2025: 42026 (partial year): 8
2007high 51 (2010) · low 1 (2020)2026

Class I (14 since 2007) Class II/III not classified

Adverse event reports per year · GEI

7,592in 2025

2007: 2,7952008: 2,5562009: 3,5912010: 3,3772011: 4,4632012: 5,2162013: 4,8972014: 4,9082015: 4,9362016: 5,6162017: 6,0732018: 6,5452019: 7,0672020: 6,4902021: 6,3542022: 6,1032023: 7,1762024: 7,8972025: 7,592
2007high 7,897 (2024) · low 2,556 (2008)2025

MAUDE reports naming product code GEI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20075051212,795
20086171192,556
200942130273,591
201046109513,377
201135135324,463
201239133305,216
201348136134,897
20144910334,908
20154712344,936
20166410835,616
2017527226,073
2018479366,545
2019489357,067
20205910516,490
20214614666,354
202255150496,103
20236510427 (4)7,176
20245912522 (10)7,897
20255211347,592
2026431838—

What is it indicated for?

The VASOVIEW HEMOPRO 2 System is indicated for use in minimally invasive surgery allowing access for vessel harvesting, and is primarily indicated for patients undergoing endoscopic surgery for arterial bypass. It is indicated for cutting tissue and controlling bleeding through coagulation, and for patients requiring blunt dissection of tissue including dissection of blood vessels, dissection of blood vessels of the extremities, dissection of ducts and…

Read the full statement (131 words)

The VASOVIEW HEMOPRO 2 System is indicated for use in minimally invasive surgery allowing access for vessel harvesting, and is primarily indicated for patients undergoing endoscopic surgery for arterial bypass. It is indicated for cutting tissue and controlling bleeding through coagulation, and for patients requiring blunt dissection of tissue including dissection of blood vessels, dissection of blood vessels of the extremities, dissection of ducts and other structures in the extraperitoneal or subcutaneous extremity and thoracic space. Extremity procedures include tissue dissection/vessel harvesting along the saphenous vein for use in coronary artery bypass grafting and peripheral artery bypass or radial artery for use in coronary artery bypass grafting. Thoracoscopic procedures include exposure and dissection of structures external to the parietal pleura, including nerves, blood vessels and other tissues of the chest wall.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K101274: Vasoview Hemopro 2 Endoscopic Vessel Harvesting System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K101274

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026