510(k) Report

510(k) · Cleared

Cleared

MD Vision System

K101474510(k) TraditionalCleared Jul 2, 201035-day reviewClass II21 CFR 870.2450

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Perkins Healthcare Technologies · DXJ Display, Cathode-Ray Tube, Medical

Cleared on Jul 2, 2010 as substantially equivalent to K083321 (Curlview Igt, LLC, 2008) and 1 other predicate after a 35-day review. Its family tree reaches back 7 generations to 1994.

Decided
Jul 2, 2010
Review
35 days
Class
Class II
Product code
DXJ
Recalls
None
Predicates
2

Its longest line of descent runs back 7 generations to K941811 (1994). 23 ancestors in all, the oldest K822695 (1982). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2006: 1 other ancestor1997: 2 other ancestors2003: 1 other ancestor1999: 1 other ancestor1993: 1 other ancestor1992: 3 other ancestors1991: 1 other ancestor1984: 1 other ancestor1982: 1 other ancestor2000: 1 other ancestor1996: 1 other ancestor1995: 1 other ancestor1994: 1 other ancestorK941811 · HP M1175A, M1176A, Component Monitoring System · Hewlett-Packard Co. · 1994K960934 · HP M1205A Omnicare Component Monitor System Model 24 · Hewlett-Packard Co. · 1996×2: 2 generations cleared close together, K981376 (1999), K990125 (1999) K992636 · HP Carevue 9000 Clinical Information System, Model M2331A · Hewlett-Packard Co. · 1999 · recalledK073372 · Electrophysiology Systems Integrator (Epsi) · Systemsone · 2007K083321 · Cardio-View · Curlview Igt, LLC · 20081980198519901995200020052010
  1. Root · 7 generations backK941811 HP M1175A, M1176A, Component Monitoring SystemHewlett-Packard Co. · 1994
  2. 6 generations backK960934 HP M1205A Omnicare Component Monitor System Model 24Hewlett-Packard Co. · 1996
  3. 5 generations backK981376 Hewlett-Packard M1205A Viridia 24 CTHewlett-Packard Co. · 1999
  4. 4 generations backK990125 HP Viridia Component Monitoring System, Model Rev. KHewlett-Packard GmbH · 1999
  5. 3 generations backK992636 HP Carevue 9000 Clinical Information System, Model M2331AHewlett-Packard Co. · 1999 · Recalled
  6. 2 generations backK073372 Electrophysiology Systems Integrator (Epsi)Systemsone · 2007
  7. 1 generation backK083321 Cardio-ViewCurlview Igt, LLC · 2008
  8. This deviceK101474 MD Vision SystemPerkins Healthcare Technologies · 2010
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K941811HP M1175A, M1176A, Component Monitoring SystemHewlett-Packard Co.1994—
−6K960934HP M1205A Omnicare Component Monitor System Model 24Hewlett-Packard Co.1996—
−5K981376Hewlett-Packard M1205A Viridia 24 CTHewlett-Packard Co.1999—
−4K990125HP Viridia Component Monitoring System, Model Rev. KHewlett-Packard GmbH1999—
−3K992636HP Carevue 9000 Clinical Information System, Model M2331AHewlett-Packard Co.19998
−2K073372Electrophysiology Systems Integrator (Epsi)Systemsone2007—
−1K083321Cardio-ViewCurlview Igt, LLC2008—
0 (this device)K101474MD Vision SystemPerkins Healthcare Technologies2010—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198210
198410
199110
199230
199310
199410
199510
199610
199720
199910
200010
200310
200610
FIG. 1 — Lineage of K101474, 1994–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXJ device

  1. #1 K261469 Nexxis 2;Nexxis OR 2;NMS 2;MNA-240;MNA-4x0…score 12.7 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K083321Cardio-View
Summary page 1
…fication Panel: Cardiovascular Equivalent Marketed Device(s): 21 CFR 807.92(a)(3) Device 1 510(k) Number: K083321 Regulation Number: 870.2450 Device Name: Cardio-View Applicant:…
Curlview Igt, LLC2008—
*K073372Electrophysiology Systems Integrator (Epsi)
Summary page 1
…uct Code: DXJ Device Classification Name: Cardiovascular Monitoring Devices Device 2 510(k) Number: K073 372 Regulation Number: 870.2450 Device Name: SystemsOne, LLC Applicant:…
Systemsone2007—

Also cleared against K083321: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 5 companies; a new generation was cleared every 1.6 years on median.
  • 3 of the 23 ancestors have a recall of any class.
  • 3 other devices also cite its predicate K083321.

How does its category compare?

All DXJ devices

DXJ Display, Cathode-Ray Tube, Medical: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · DXJ

2in 2021

2007: 12008: 12010: 22011: 42012: 12013: 32014: 42015: 22016: 12017: 42018: 42020: 12021: 22026 (partial year): 1
2007high 4 (2011) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXJ

130in 2018

2011: 53 days median2013: 174 days median2014: 242 days median2017: 164 days median2018: 130 days median
2007high 242 (2014) · low 53 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXJ

2in 2025

2008: 22009: 82010: 12011: 12022: 12025: 2
2007high 8 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DXJ

3in 2025

2007: 32008: 52009: 292010: 1482011: 1292012: 212013: 42014: 132015: 152016: 72017: 102018: 32019: 292020: 222021: 62022: 22023: 172024: 152025: 3
2007high 148 (2010) · low 2 (2022)2025

MAUDE reports naming product code DXJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—03
20081—25
20090—829
20102—1148
20114531129
20121—021
2013317404
20144242013
20152—015
20161—07
20174164010
2018413003
20190—029
20201—022
20212—06
20220—12
20230—017
20240—015
20250—23
20261—0—

What is it indicated for?

The MD VISION System is a video integration system that takes the original source image from one or more devices and sends it out to a variety of locations. * It integrates images from as many as twelve individual video sources (e.g., VGA, DVI, Coaxial, S-video, etc.) * It processes these video inputs (e.g., by size, position, location) * It displays up to 12 images on a Flat Panel LCD display a A touchscreen pad controls the LCD display a It has no…

Read the full statement (140 words)

The MD VISION System is a video integration system that takes the original source image from one or more devices and sends it out to a variety of locations.

* It integrates images from as many as twelve individual video sources (e.g., VGA, DVI, Coaxial, S-video, etc.)

* It processes these video inputs (e.g., by size, position, location)

* It displays up to 12 images on a Flat Panel LCD display

a A touchscreen pad controls the LCD display

a It has no patient applied padts

Typical users are:

• The procedure suite clinicians who need information from several sources on screen instantly showing the visual information in the way they want to see it on a large LCID display that facilitates viewing.

* Users who want to show medical procedures in real time or record medical procedures for teaching.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K101474: MD Vision System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K101474

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026