510(k) Report

510(k) · Cleared

Recalled · Class II · 2012

Stingray Orienting Balloon Catheter

K101591510(k) SpecialCleared Aug 6, 201060-day reviewClass II21 CFR 870.1250Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bridgepoint Medical · DQY Catheter, Percutaneous

Cleared on Aug 6, 2010 as substantially equivalent to K080987 (Bridgepoint Medical, 2009) after a 60-day review. Its family tree reaches back 7 generations to 1994. 3 of the 38 devices in its family, counting itself, have a Class I recall. 14 later devices descend from it. It has been recalled once.

Decided
Aug 6, 2010
Review
60 days
Class
Class II
Product code
DQY
Recalls
1
Predicates
1

Its longest line of descent runs back 7 generations to K931794 (1994). 23 ancestors in all, the oldest K904785 (1991). 14 later devices descend from it, 2 citing it directly. 3 of the 38 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2004: 1 other ancestor2002: 2 other ancestors2003: 1 other ancestor2001: 3 other ancestors2000: 3 other ancestors1999: 1 other ancestor1998: 1 other ancestor1991: 1 other ancestor1997: 1 other ancestor1996: 2 other ancestors2011: 2 descendants cleared2014: 1 descendant cleared2012: 4 descendants cleared2020: 2 descendants cleared2015: 1 descendant cleared2019: 1 descendant cleared2023: 2 descendants cleared2026: 1 descendant clearedK931794 · Marinr Series EP Diagnostic Catheters · Medtronic Cardiorhythm · 1994K974683 · Naviport Deflectable Tip Guiding Catheter · Cardima, Inc. · 1999K012749 · Biocardia Universal Deflectable Guide Catheter, Model 000664 · Biocardia, Inc. · 2002×2: 2 generations cleared close together, K040922 (2004), K042910 (2004) K061843 · Venture Wire Control Catheter, Model WCC · St Jude Medical · 2006 · Class I recallK080987 · Bridgepoint Medical Stingray Device and Accessories · Bridgepoint Medical · 2009 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 2 other ancestors3 generations back: 8 other ancestors4 generations back: 2 other ancestors5 generations back: 1 other ancestor6 generations back: 2 other ancestors7 generations back: 1 other ancestor 1 generation forward: 2 descendants2 generations forward: 6 descendants3 generations forward: 5 descendants4 generations forward: 1 descendant K080987 · Bridgepoint Medical Stingray Device and Accessories · Bridgepoint Medical · 2009 · recalledK061843 · Venture Wire Control Catheter, Model WCC · St Jude Medical · 2006 · Class I recallK042910 · Venture Wire Control Catheter, Model WCC · Velocimed, Inc. · 2004 · Class I recallK040922 · Venture Wire Control Catheter · Velocimed, Inc. · 2004 · Class I recallK012749 · Biocardia Universal Deflectable Guide Catheter, Model 000664 · Biocardia, Inc. · 2002K974683 · Naviport Deflectable Tip Guiding Catheter · Cardima, Inc. · 1999K931794 · Marinr Series EP Diagnostic Catheters · Medtronic Cardiorhythm · 1994−50
  1. Root · 7 generations backK931794 Marinr Series EP Diagnostic CathetersMedtronic Cardiorhythm · 1994
  2. 6 generations backK974683 Naviport Deflectable Tip Guiding CatheterCardima, Inc. · 1999
  3. 5 generations backK012749 Biocardia Universal Deflectable Guide Catheter, Model 000664Biocardia, Inc. · 2002
  4. 4 generations backK040922 Venture Wire Control CatheterVelocimed, Inc. · 2004 · Recalled (Class I)
  5. 3 generations backK042910 Venture Wire Control Catheter, Model WCCVelocimed, Inc. · 2004 · Recalled (Class I)
  6. 2 generations backK061843 Venture Wire Control Catheter, Model WCCSt Jude Medical · 2006 · Recalled (Class I)
  7. 1 generation backK080987 Bridgepoint Medical Stingray Device and AccessoriesBridgepoint Medical · 2009 · Recalled
  8. This deviceK101591 Stingray Orienting Balloon CatheterBridgepoint Medical · 2010
  9. Descendant · cites it directly · 11 of its ownK102725 Crossboss Catheter Model M-2000, Stingray Orienting Balloon Catheter…Bridge Medical, Inc. · 2011 · Recalled
  10. Descendant · cites it directly · 7 of its ownK111963 Bridgepoint Medical Mantaray (TM) CatheterBridgepoint Medical · 2011
  11. Descendant · 2 generations on · 6 of its ownK120129 Mantaray CatheterBridgepoint Medical · 2012
  12. Descendant · 2 generations on · 5 of its ownK120533 Bigboss Catheters Mantatay Catheter Mantaray GuidewiresBridgepoint Medical · 2012
  13. Descendant · 3 generations on · 1 of its ownK193596 Wingman 14, Wingman 14C, Wingman 18, Wingman 35Reflow Medical · 2020

Showing 5 of 14 descendants. See all descendants

Descendants cleared per year

2011: 22012: 42014: 12015: 12019: 12020: 22023: 22026: 1
2011high 4 (2012) · low 0 (2013)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 14 · See all
  • K102725Crossboss Catheter Model M-2000, Stingray Orienting Balloon Catheter Model M-1000…Bridge Medical, Inc. · 2011 · cites it directly11descendants
  • K111963Bridgepoint Medical Mantaray (TM) CatheterBridgepoint Medical · 2011 · cites it directly7descendants
  • K120129Mantaray CatheterBridgepoint Medical · 2012 · 2 generations on6descendants
  • K120533Bigboss Catheters Mantatay Catheter Mantaray GuidewiresBridgepoint Medical · 2012 · 2 generations on5descendants
  • K193596Wingman 14, Wingman 14C, Wingman 18, Wingman 35Reflow Medical · 2020 · 3 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K931794Marinr Series EP Diagnostic CathetersMedtronic Cardiorhythm1994—
−6K974683Naviport Deflectable Tip Guiding CatheterCardima, Inc.1999—
−5K012749Biocardia Universal Deflectable Guide Catheter, Model 000664Biocardia, Inc.2002—
−4K040922Venture Wire Control CatheterVelocimed, Inc.2004Class I
−3K042910Venture Wire Control Catheter, Model WCCVelocimed, Inc.2004Class I
−2K061843Venture Wire Control Catheter, Model WCCSt Jude Medical2006Class I
−1K080987Bridgepoint Medical Stingray Device and AccessoriesBridgepoint Medical20091
0 (this device)K101591Stingray Orienting Balloon CatheterBridgepoint Medical2010—
+1K102725Crossboss Catheter Model M-2000, Stingray Orienting Balloon Catheter Model…Bridge Medical, Inc.20111
+1K111963Bridgepoint Medical Mantaray (TM) CatheterBridgepoint Medical2011—
+2K120129Mantaray CatheterBridgepoint Medical2012—
+2K120533Bigboss Catheters Mantatay Catheter Mantaray GuidewiresBridgepoint Medical2012—
+3K193596Wingman 14, Wingman 14C, Wingman 18, Wingman 35Reflow Medical2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199620
199710
199810
199910
200030
200130
200220
200310
200410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201120
201240
201410
201510
201910
202020
202320
202610
FIG. 1 — Lineage of K101591, 1994–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQY device

  1. #1 K234115 APRO 55 Catheterscore 17.5 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K080987Bridgepoint Medical Stingray Device and Accessories
Summary page 1
…int Medical Stingray Orienting Balloon Catheter is substantially equivalent in intended use, method of operation and technical aspects to the following predicate device: K080987 - Stingray TM Orienting Balloon Catheter…
Bridgepoint Medical20091

Also cleared against K080987: 3 other devices →

What descends from it? (14)

See all 14

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K102725Crossboss Catheter Model M-2000, Stingray Orienting Balloon Catheter Model M-1000…Bridge Medical, Inc.201111
K111963Bridgepoint Medical Mantaray (TM) CatheterBridgepoint Medical20117

Has anything in its family been recalled? (3 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 26, 2012Class IIZ-2074-2012Process controlBridgePoint Medical Inc. is voluntarily recalling Stingray Catheter, Model M1000 lots BP20121440078 and BP20121560089. BridgePoint Medical, Inc. recently determined the potential of compromised sterility assurance of the product due to a…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K061843Venture Wire Control Catheter, Model WCCSt Jude Medical · 2006 · 2 generations back · ◆ on the line of descent in FIG. 11 Class I recall
  • K042910Venture Wire Control Catheter, Model WCCVelocimed, Inc. · 2004 · 3 generations back · ◆ on the line of descent in FIG. 11 Class I recall
  • K040922Venture Wire Control CatheterVelocimed, Inc. · 2004 · 4 generations back · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 16 years and passes through 6 companies; a new generation was cleared every 2.5 years on median.
  • 8 of the 23 ancestors have a recall of any class; 3 have a Class I recall.
  • Of its descendants, K102725 (Bridge Medical, Inc., 2011) has gone furthest, with 11 descendants of its own.
  • 3 other devices also cite its predicate K080987.

How does its category compare?

All DQY devices

DQY Catheter, Percutaneous: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · DQY

21in 2025

2007: 162008: 312009: 372010: 222011: 362012: 302013: 322014: 192015: 272016: 222017: 262018: 252019: 302020: 202021: 182022: 182023: 182024: 162025: 212026 (partial year): 11
2007high 37 (2009) · low 16 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQY

115in 2025

2007: 85 days median2008: 66 days median2009: 73 days median2010: 74 days median2011: 71 days median2012: 87 days median2013: 92 days median2014: 127 days median2015: 118 days median2016: 117 days median2017: 113 days median2018: 106 days median2019: 111 days median2020: 120 days median2021: 81 days median2022: 74 days median2023: 114 days median2024: 87 days median2025: 115 days median2026 (partial year): 30 days median
2007high 127 (2014) · low 66 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQY

1in 2025

2007: 62008: 122009: 172010: 322011: 62012: 22013: 36, 1 Class I2014: 32015: 32016: 22, 7 Class I2017: 82018: 22019: 12020: 22021: 22023: 172024: 12025: 1, 1 Class I2026 (partial year): 2, 1 Class I
2007high 36 (2013) · low 0 (2022)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · DQY

3,056in 2025

2007: 3132008: 4962009: 8192010: 1,2932011: 1,2112012: 1,1912013: 1,3522014: 1,4972015: 2,3372016: 2,2522017: 2,4892018: 2,8552019: 2,9022020: 2,8892021: 3,0062022: 2,6432023: 3,0492024: 3,1902025: 3,056
2007high 3,190 (2024) · low 313 (2007)2025

MAUDE reports naming product code DQY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200716856313
2008316612496
2009377317819
20102274321,293
2011367161,211
2012308721,191
2013329236 (1)1,352
20141912731,497
20152711832,337
20162211722 (7)2,252
20172611382,489
20182510622,855
20193011112,902
20202012022,889
2021188123,006
2022187402,643
202318114173,049
2024168713,190
2025211151 (1)3,056
202611302 (1)—

What is it indicated for?

The BridgePoint Medical StingrayTM Orienting Balloon Catheter is indicated for

directing, steering, controlling, and supporting a guidewire in order to access discrete

regions of the coronary and peripheral vaseulature

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K101591: Stingray Orienting Balloon Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K101591

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026