510(k) · Cleared
ClearedWildcat 5F Guidewire Support Catheter, Mode W500
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Avinger, Inc. · DQY Catheter, Percutaneous
Cleared on Aug 6, 2010 as substantially equivalent to K083313 (Avinger, Inc., 2009) after a 56-day review. Its family tree reaches back 7 generations to 2000. 1 of the 27 devices in its family, counting itself, has a Class I recall. 2 later devices descend from it.
- Decided
- Aug 6, 2010
- Review
- 56 days
- Class
- Class II
- Product code
- DQY
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 7 generations to K001992 (2000). 24 ancestors in all, the oldest K861606 (1986). 2 later devices descend from it, 2 citing it directly. 1 of the 27 devices in this family, counting this one, has a Class I recall.
- Root · 7 generations backK001992 Ilt 0.014 Catheter, Model C114NL2Intra Luminal Therapeutics, Inc. · 2000
- 6 generations backK012169 Ilt Support Catheter .014, Model C114LW1; Ilt Support Catheter…Intra Luminal Therapeutics, Inc. · 2001
- 5 generations backK030984 Safe Cross Angled Support 0.14, Safe Cross Straight Support Catheter…Intra Luminal Therapeutics, Inc. · 2003
- 4 generations backK032660 Xtrak Support CatheterXtrak Medical, Inc. · 2003
- 3 generations backK051772 Asahi Tornus Support CatheterAsahi Intecc Co., Ltd. · 2005
- 2 generations backK060745 Asahi Tornus Support Catheter with Torque Device AccessoryAsahi Intecc Co., Ltd. · 2006
- 1 generation backK083313 Wildcat 7F Guidewire Support CatheterAvinger, Inc. · 2009
- This deviceK101647 Wildcat 5F Guidewire Support Catheter, Mode W500Avinger, Inc. · 2010
- Descendant · cites it directly · 1 of its ownK112579 Wildcat 5F Guidewire Support CatheterAvinger, Inc. · 2011
- Descendant · cites it directly · 0 of its ownK120273 Kittycat Catheter, Kittycat 2 CatheterAvinger, Inc. · 2012
Class I recalls in this family
- K060327 Vascular Solutions Twin-Pass Dual Access…3 generations back · 2006
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −7 | K001992 | Ilt 0.014 Catheter, Model C114NL2 | Intra Luminal Therapeutics, Inc. | 2000 | — |
| −6 | K012169 | Ilt Support Catheter .014, Model C114LW1; Ilt Support Catheter Advancing… | Intra Luminal Therapeutics, Inc. | 2001 | — |
| −5 | K030984 | Safe Cross Angled Support 0.14, Safe Cross Straight Support Catheter 0.14… | Intra Luminal Therapeutics, Inc. | 2003 | — |
| −4 | K032660 | Xtrak Support Catheter | Xtrak Medical, Inc. | 2003 | — |
| −3 | K051772 | Asahi Tornus Support Catheter | Asahi Intecc Co., Ltd. | 2005 | — |
| −2 | K060745 | Asahi Tornus Support Catheter with Torque Device Accessory | Asahi Intecc Co., Ltd. | 2006 | — |
| −1 | K083313 | Wildcat 7F Guidewire Support Catheter | Avinger, Inc. | 2009 | — |
| 0 (this device) | K101647 | Wildcat 5F Guidewire Support Catheter, Mode W500 | Avinger, Inc. | 2010 | — |
| +1 | K112579 | Wildcat 5F Guidewire Support Catheter | Avinger, Inc. | 2011 | — |
| +1 | K120273 | Kittycat Catheter, Kittycat 2 Catheter | Avinger, Inc. | 2012 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1986 | 2 | 0 |
| 1991 | 1 | 0 |
| 1993 | 1 | 0 |
| 1994 | 1 | 0 |
| 1995 | 1 | 0 |
| 1999 | 1 | 0 |
| 2000 | 3 | 0 |
| 2002 | 2 | 0 |
| 2003 | 1 | 0 |
| 2004 | 1 | 0 |
| 2005 | 1 | 0 |
| 2006 | 1 | 1 |
| 2007 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2011 | 1 | 0 |
| 2012 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DQY device
- #1 K234115 APRO 55 Catheterscore 17.5 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K083313 | Wildcat 7F Guidewire Support CatheterSummary page 1…Name: Percutaneous Catheter (21 CFR § 870.1250) Product Code: DEY Cleared Device: Wildcat 7F Guidewire Support Catheter (K083313) Device Description: The Wildcat 5F Guidewire Support Catheter isa SF sheath and 0.014" guidewire compatible over-the- wire dev… | 2009 |
What descends from it? (2)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (1 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K060327Vascular Solutions Twin-Pass Dual Access Catheter and Skyway Support CatheterVascular Solutions, Inc. · 2006 · 3 generations back · ◆ in the 2006 ancestors bar of FIG. 11 Class I recall
What does this lineage say?
- The line of descent spans 10 years and passes through 4 companies; a new generation was cleared every 1.5 years on median.
- 2 of the 24 ancestors have a recall of any class; 1 has a Class I recall.
- Of its descendants, K112579 (Avinger, Inc., 2011) has gone furthest, with 1 descendant of its own.
- 1 other device also cites its predicate K083313.
How does its category compare?
All DQY devicesDQY Catheter, Percutaneous: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.
FDA decisions per year · DQY
21in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DQY
115in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DQY
1in 2025
Class I (10 since 2007) Class II/III not classified
Adverse event reports per year · DQY
3,056in 2025
MAUDE reports naming product code DQY, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 16 | 85 | 6 | 313 |
| 2008 | 31 | 66 | 12 | 496 |
| 2009 | 37 | 73 | 17 | 819 |
| 2010 | 22 | 74 | 32 | 1,293 |
| 2011 | 36 | 71 | 6 | 1,211 |
| 2012 | 30 | 87 | 2 | 1,191 |
| 2013 | 32 | 92 | 36 (1) | 1,352 |
| 2014 | 19 | 127 | 3 | 1,497 |
| 2015 | 27 | 118 | 3 | 2,337 |
| 2016 | 22 | 117 | 22 (7) | 2,252 |
| 2017 | 26 | 113 | 8 | 2,489 |
| 2018 | 25 | 106 | 2 | 2,855 |
| 2019 | 30 | 111 | 1 | 2,902 |
| 2020 | 20 | 120 | 2 | 2,889 |
| 2021 | 18 | 81 | 2 | 3,006 |
| 2022 | 18 | 74 | 0 | 2,643 |
| 2023 | 18 | 114 | 17 | 3,049 |
| 2024 | 16 | 87 | 1 | 3,190 |
| 2025 | 21 | 115 | 1 (1) | 3,056 |
| 2026 | 11 | 30 | 2 (1) | — |
What is it indicated for?
The Wildcat 5F Guidewire Support Catheter is intended to be used to support steerable guidiewires in accessing discrete regions of the peripheral vasculature. It may be used to facilitate placement and exchange of guidewires and other interventional devices. It may also be used to deliver saline/contrast.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K101647 · printed Nov 6, 2026
Cite this page
510(k) Report. “K101647: Wildcat 5F Guidewire Support Catheter, Mode W500.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K101647
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026