510(k) · Cleared
ClearedEndovascular Laer Vein System Kit
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Biolitec, Inc. · GEX Powered Laser Surgical Instrument
Cleared on Oct 27, 2010 after a 131-day review. The FDA summary names its predicate without a number. 29 later devices descend from it.
- Decided
- Oct 27, 2010
- Review
- 131 days
- Class
- Class II
- Product code
- GEX
- Recalls
- None
- Predicates
- 0
29 later devices descend from it, 3 citing it directly.
- This deviceK101712 Endovascular Laer Vein System KitBiolitec, Inc. · 2010
- Descendant · cites it directly · 26 of its ownK110080 Radial-Emitting Shaped Fiber Optic Delivery SystemBiolitec, Inc. · 2011
- Descendant · 2 generations on · 24 of its ownK120810 Fiberoptic Laser Delivery SystemFiberoptic Fabrications, Inc. · 2012
- Descendant · 2 generations on · 23 of its ownK124003 Med-Fibers Surgical Laser Fiber, Med-Fibers Endo-Ent Laser Probes…Med-Fibers, Inc. · 2013
- Descendant · 3 generations on · 13 of its ownK170366 Laser Peripherals, LLC Family of Bare Laser FibersLaser Peripherals, LLC · 2017
- Descendant · 4 generations on · 5 of its ownK220189 LISA Laser Surgical FibersOmni-Guide Holdings, Inc. · 2022
Showing 5 of 29 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 29 · See all- K110080Radial-Emitting Shaped Fiber Optic Delivery SystemBiolitec, Inc. · 2011 · cites it directly26descendants
- K120810Fiberoptic Laser Delivery SystemFiberoptic Fabrications, Inc. · 2012 · 2 generations on24descendants
- K124003Med-Fibers Surgical Laser Fiber, Med-Fibers Endo-Ent Laser Probes, Med-Fibers End- and…Med-Fibers, Inc. · 2013 · 2 generations on23descendants
- K170366Laser Peripherals, LLC Family of Bare Laser FibersLaser Peripherals, LLC · 2017 · 3 generations on13descendants
- K220189LISA Laser Surgical FibersOmni-Guide Holdings, Inc. · 2022 · 4 generations on5descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K101712 | Endovascular Laer Vein System Kit | Biolitec, Inc. | 2010 | — |
| +1 | K110080 | Radial-Emitting Shaped Fiber Optic Delivery System | Biolitec, Inc. | 2011 | — |
| +2 | K120810 | Fiberoptic Laser Delivery System | Fiberoptic Fabrications, Inc. | 2012 | — |
| +2 | K124003 | Med-Fibers Surgical Laser Fiber, Med-Fibers Endo-Ent Laser Probes, Med-Fibers… | Med-Fibers, Inc. | 2013 | — |
| +3 | K170366 | Laser Peripherals, LLC Family of Bare Laser Fibers | Laser Peripherals, LLC | 2017 | — |
| +4 | K220189 | LISA Laser Surgical Fibers | Omni-Guide Holdings, Inc. | 2022 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2011 | 3 | 0 |
| 2012 | 1 | 0 |
| 2013 | 2 | 0 |
| 2014 | 2 | 0 |
| 2015 | 1 | 0 |
| 2016 | 3 | 0 |
| 2017 | 2 | 0 |
| 2020 | 1 | 0 |
| 2021 | 1 | 0 |
| 2022 | 2 | 0 |
| 2023 | 2 | 0 |
| 2024 | 3 | 0 |
| 2025 | 5 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in GEX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new GEX device
- #1 K222064 The Alma Soprano Titaniumscore 38.1 · 24 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Ceralas D Diode Laser System (1470nm, 980•`m and 810 urn) with ELVeS Kit Named without a submission number | |
| † | K924258 | Megabeam Radial Emit Shape Fiber Optic Deliv Syst | 1994 |
What descends from it? (29)
See all 293 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K110080 (Biolitec, Inc., 2011) has gone furthest, with 26 descendants of its own.
How does its category compare?
All GEX devicesGEX Powered Laser Surgical Instrument: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.
FDA decisions per year · GEX
83in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · GEX
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · GEX
3in 2024
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · GEX
2,720in 2025
MAUDE reports naming product code GEX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 73 | 79 | 9 | 342 |
| 2008 | 107 | 86 | 2 | 232 |
| 2009 | 69 | 100 | 0 | 209 |
| 2010 | 50 | 96 | 4 | 1,711 |
| 2011 | 41 | 83 | 18 | 3,024 |
| 2012 | 45 | 118 | 5 | 2,000 |
| 2013 | 46 | 144 | 3 | 2,236 |
| 2014 | 61 | 147 | 6 | 2,036 |
| 2015 | 47 | 112 | 0 | 2,099 |
| 2016 | 51 | 114 | 1 | 2,585 |
| 2017 | 67 | 90 | 5 (1) | 2,977 |
| 2018 | 51 | 78 | 5 | 3,525 |
| 2019 | 41 | 88 | 6 | 2,709 |
| 2020 | 52 | 90 | 1 | 2,183 |
| 2021 | 53 | 123 | 0 | 3,465 |
| 2022 | 60 | 152 | 0 | 2,288 |
| 2023 | 52 | 87 | 6 | 2,337 |
| 2024 | 82 | 90 | 3 | 2,187 |
| 2025 | 83 | 90 | 0 | 2,720 |
| 2026 | 57 | 90 | 2 | — |
What is it indicated for?
For endovascular coagulation of the greater saphenous vein of the thigh in patients with superficial vein reflux.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K101712 · printed Nov 6, 2026
Cite this page
510(k) Report. “K101712: Endovascular Laer Vein System Kit.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K101712
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026