Recalled · Class II · 2013Exactech Novation Empire Acetabular Augment with Integrip Model 186-01-08/11/13, 186-02-08/11/13, 186-03-08/11/13
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Exactech, Inc. · LPH Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
Cleared on Sep 21, 2010 after a 90-day review. The summary cites one number, which could not be confirmed as its predicate (see the table below). 1 later device descends from it. It has been recalled once.
- Decided
- Sep 21, 2010
- Review
- 90 days
- Class
- Class II
- Product code
- LPH
- Recalls
- 1
- Predicates
- 1
1 later device descends from it, 1 citing it directly.
- This deviceK101761 Exactech Novation Empire Acetabular Augment with Integrip Model…Exactech, Inc. · 2010
- Descendant · cites it directly · 0 of its ownK113609 Novation Integrip Acetabular Augments, Groups 4 and 5Exactech, Inc. · 2012 · Recalled
Most influential descendants
Showing 1 of 1 · See all- K113609Novation Integrip Acetabular Augments, Groups 4 and 5Exactech, Inc. · 2012 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K101761 | Exactech Novation Empire Acetabular Augment with Integrip Model… | Exactech, Inc. | 2010 | — |
| +1 | K113609 | Novation Integrip Acetabular Augments, Groups 4 and 5 | Exactech, Inc. | 2012 | 1 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2012 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LPH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LPH device
- #1 K233498 Stryker Orthopaedics Hip Systems Labeling Updatescore 24.2 · 20 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.
| Type | Number | Device | Decided |
|---|---|---|---|
| Kept off the family tree | K001471 | FDA’s K001471 is The Implex Hedrocel Acetabular Augment, XX-Yyy-ZZZZ Not matched in our reading of the summary (scans can blur digits), so it is kept off the family tree | 2000 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K113609 | Novation Integrip Acetabular Augments, Groups 4 and 5 | 2012 | 0 |
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Sep 11, 2013 | Class II | Z-0906-2014 | Employee error | Exactech is recalling the InteGrip Acetabular Augments due to an out of range condition for an in-vitro biological evaluation standard. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K113609 (Exactech, Inc., 2012) has gone furthest, with 0 descendants of its own.
How does its category compare?
All LPH devicesLPH Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.
FDA decisions per year · LPH
12in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LPH
153in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LPH
4in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LPH
6,163in 2025
MAUDE reports naming product code LPH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 10 | 116 | 16 | 509 |
| 2008 | 10 | 86 | 1 | 706 |
| 2009 | 3 | 112 | 2 | 1,156 |
| 2010 | 15 | 100 | 22 | 2,007 |
| 2011 | 16 | 110 | 26 | 3,320 |
| 2012 | 25 | 76 | 30 | 3,785 |
| 2013 | 11 | 135 | 9 | 5,002 |
| 2014 | 20 | 129 | 3 | 5,163 |
| 2015 | 18 | 111 | 1 | 5,830 |
| 2016 | 10 | 150 | 8 | 4,900 |
| 2017 | 12 | 121 | 14 | 5,312 |
| 2018 | 9 | 145 | 2 | 5,954 |
| 2019 | 22 | 164 | 8 | 7,130 |
| 2020 | 7 | 164 | 6 | 5,429 |
| 2021 | 8 | 410 | 4 | 5,978 |
| 2022 | 14 | 247 | 2 | 5,223 |
| 2023 | 10 | 111 | 2 | 5,345 |
| 2024 | 6 | 92 | 1 | 5,626 |
| 2025 | 12 | 153 | 4 | 6,163 |
| 2026 | 8 | 256 | 2 | — |
What is it indicated for?
The Empire Acetabular Augments are indicated for use in skeletally mature individuals undergoing primary or revision surgery for hip replacement and whose orthopedic surgeon desires a prosthetic alternative to structural allograft in cases of segmental acetabular deficiencies.
The Empire Acetabular Augment is affixed to the mating acetabular shell using PMMA bone cement. Therefore, acetabular shells with HA coating must not be used with Empire Acetabular Augments. The assembled construct is intended for press-fit fixation. The construct may also be used with bone cement at the discretion of the surgeon.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K101761 · printed Nov 5, 2026
Cite this page
510(k) Report. “K101761: Exactech Novation Empire Acetabular Augment with Integrip Model 186-01-08/11/13, 186-02-08/11/13, 186-03-08/11/13.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K101761
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026