510(k) · Cleared
ClearedMH1 Microholter Recorder
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Exelys, LLC · MWJ Electrocardiograph, Ambulatory (Without Analysis)
Cleared on Feb 4, 2011 as substantially equivalent to K071733 (Braemar, Inc., 2007) after a 206-day review. Its family tree reaches back 1 generation to 2007.
- Decided
- Feb 4, 2011
- Review
- 206 days
- Class
- Class II
- Product code
- MWJ
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K071733 (2007). No later device cites it as a predicate yet.
- Root · 1 generation backK071733 DL900 Series Holter RecorderBraemar, Inc. · 2007 · Recalled
- This deviceK101969 MH1 Microholter RecorderExelys, LLC · 2011
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K071733 | DL900 Series Holter Recorder | Braemar, Inc. | 2007 | 3 |
| 0 (this device) | K101969 | MH1 Microholter Recorder | Exelys, LLC | 2011 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MWJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MWJ device
- #1 K254119 Wearable ECG Recorder (YMHeart XY-12)…score 14.1 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K071733 | DL900 Series Holter RecorderSummary page 2…llowing FDA cleared predicate device with regard to indications for use, performance and technological characteristics: 510O(k) Numb&e: K07 1733 Trade Name: DL900 Series Rolter Recorder Manufacturer: Braemar, Inc.… | 2007 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Its one ancestor has a recall.
- 1 other device also cites its predicate K071733.
How does its category compare?
All MWJ devicesMWJ Electrocardiograph, Ambulatory (Without Analysis): FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.
FDA decisions per year · MWJ
2in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · MWJ
337in 2022
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MWJ
2in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MWJ
8in 2025
MAUDE reports naming product code MWJ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 5 | 142 | 0 | 0 |
| 2008 | 1 | — | 0 | 0 |
| 2009 | 2 | — | 0 | 5 |
| 2010 | 3 | 90 | 0 | 0 |
| 2011 | 3 | 206 | 0 | 0 |
| 2012 | 1 | — | 0 | 2 |
| 2013 | 3 | 241 | 0 | 4 |
| 2014 | 2 | — | 0 | 1 |
| 2015 | 0 | — | 0 | 1 |
| 2016 | 2 | — | 0 | 1 |
| 2017 | 0 | — | 0 | 2 |
| 2018 | 1 | — | 0 | 1 |
| 2019 | 0 | — | 0 | 4 |
| 2020 | 0 | — | 0 | 12 |
| 2021 | 1 | — | 0 | 3 |
| 2022 | 4 | 337 | 0 | 6 |
| 2023 | 0 | — | 0 | 5 |
| 2024 | 2 | — | 2 | 3 |
| 2025 | 0 | — | 0 | 8 |
| 2026 | 5 | 270 | 0 | — |
What is it indicated for?
The MII Microolter Recorder is intended for patients requiring ambulatory (Holter) monitoring. Such monitoring is most frequently used for the following indications: * Evaluation of symptoms suggesting arrhythmia or myocardial ischemnia. * Evaluation of ECG documenting therapeutic interventions in individual patients or groups of patients. * Evaluation of patients for ST segment changes. * Evaluation of a patient's response after resuming occupational or…
Read the full statement (99 words)
The MII Microolter Recorder is intended for patients requiring ambulatory (Holter) monitoring. Such monitoring is most frequently used for the following indications:
* Evaluation of symptoms suggesting arrhythmia or myocardial ischemnia.
* Evaluation of ECG documenting therapeutic interventions in individual patients or groups of patients.
* Evaluation of patients for ST segment changes.
* Evaluation of a patient's response after resuming occupational or recreational activities (e.g. after M.I. or cardiac surgery).
* Clinical and epidemiological research studies.
* Evaluation of patients with pacemakers.
* Indication of time and frequency domain headt rate variability.
*Evaluation of patient for QT interval.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K101969 · printed Nov 6, 2026
Cite this page
510(k) Report. “K101969: MH1 Microholter Recorder.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K101969
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026