510(k) · Cleared
ClearedMed-RX Transfer Set, Models 10-1227TS, 10-1300TS, 10-1305TS and 10-1306TS
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Benlan, Inc. · FPA Set, Administration, Intravascular
Cleared on Nov 8, 2010 as substantially equivalent to K022431 (Medrad, Inc., 2002) and 1 other predicate after a 108-day review. Its family tree reaches back 4 generations to 1991.
- Decided
- Nov 8, 2010
- Review
- 108 days
- Class
- Class II
- Product code
- FPA
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 4 generations to K903493 (1991). No later device cites it as a predicate yet.
- Root · 4 generations backK903493 Namic Contrast Savings Delivery SystemNorth American Instrument Corp. · 1991
- 3 generations backK961794 Fluid Administration Set - Contrast ManagerMerit Medical Systems, Inc. · 1996
- 2 generations backK022431 Medrad Transfer SetMedrad, Inc. · 2002
- 1 generation backK031808 Medrad Swabbable Valve Transfer SetMedrad, Inc. · 2003
- This deviceK102073 Med-RX Transfer Set, Models 10-1227TS, 10-1300TS, 10-1305TS and…Benlan, Inc. · 2010
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K903493 | Namic Contrast Savings Delivery System | North American Instrument Corp. | 1991 | — |
| −3 | K961794 | Fluid Administration Set - Contrast Manager | Merit Medical Systems, Inc. | 1996 | — |
| −2 | K022431 | Medrad Transfer Set | Medrad, Inc. | 2002 | — |
| −1 | K031808 | Medrad Swabbable Valve Transfer Set | Medrad, Inc. | 2003 | — |
| 0 (this device) | K102073 | Med-RX Transfer Set, Models 10-1227TS, 10-1300TS, 10-1305TS and 10-1306TS | Benlan, Inc. | 2010 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FPA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FPA device
- #1 K243841 Sparta Infusion Set for Insulinscore 13.4 · 3 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K022431 | Medrad Transfer SetSummary page 3…There are no significant differences between the proposed MED-RX Transfer Sets and the predicate devices, Medrad Transfer Set (K022431) and Medrad Swabbable Valve Transfer Set (KO31808). Similarities between the proposed device and the pre… | 2002 |
| * | K031808 | Medrad Swabbable Valve Transfer SetSummary page 1…Predicate Device: Medrad Transfer Set (K(022431) Medrad Swabbable Valve Transfer Set (KO031808) Device Description The MVED-RX Transfer Set isoffered in four (4)different… | 2003 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 19 years and passes through 4 companies; a new generation was cleared every 6.1 years on median.
- None of the 4 ancestors has a recall.
- 3 other devices also cite its predicate K022431.
How does its category compare?
All FPA devicesFPA Set, Administration, Intravascular: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.
FDA decisions per year · FPA
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FPA
225in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FPA
98in 2025
Class I (17 since 2007) Class II/III not classified
Adverse event reports per year · FPA
34,506in 2025
MAUDE reports naming product code FPA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 16 | 75 | 17 | 1,499 |
| 2008 | 18 | 89 | 15 | 1,941 |
| 2009 | 10 | 166 | 166 | 2,512 |
| 2010 | 23 | 120 | 58 | 2,537 |
| 2011 | 12 | 87 | 28 | 4,407 |
| 2012 | 21 | 96 | 16 (4) | 4,930 |
| 2013 | 13 | 90 | 64 | 4,651 |
| 2014 | 22 | 89 | 24 | 4,695 |
| 2015 | 17 | 123 | 6 | 6,625 |
| 2016 | 12 | 195 | 10 | 8,470 |
| 2017 | 17 | 240 | 13 | 6,462 |
| 2018 | 4 | 177 | 4 | 6,574 |
| 2019 | 7 | 161 | 13 | 11,227 |
| 2020 | 10 | 327 | 107 | 9,563 |
| 2021 | 13 | 186 | 1 | 10,414 |
| 2022 | 14 | 213 | 9 (5) | 13,393 |
| 2023 | 14 | 340 | 12 (4) | 10,916 |
| 2024 | 7 | 244 | 13 (1) | 47,210 |
| 2025 | 11 | 225 | 98 (1) | 34,506 |
| 2026 | 5 | 266 | 10 (2) | — |
What is it indicated for?
The MED-RX Transfer Set is intended to be used in the delivery of contrast media or saline from a spikeable container into a syringe.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K102073 · printed Nov 5, 2026
Cite this page
510(k) Report. “K102073: Med-RX Transfer Set, Models 10-1227TS, 10-1300TS, 10-1305TS and 10-1306TS.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K102073
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026