510(k) Report

510(k) · Decided

Decided

Bard Dignishield Stool Management System

K102391510(k) TraditionalDecided Dec 22, 2010121-day reviewClass II21 CFR 876.5980

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

C.R. Bard, Inc. · KNT Tubes, Gastrointestinal (And Accessories)

Cleared on Dec 22, 2010 as substantially equivalent to K073598 (C.R. Bard, Inc., 2008) and 1 other predicate after a 121-day review. Its family tree reaches back 4 generations to 1982. 4 later devices descend from it.

Decided
Dec 22, 2010
Review
121 days
Class
Class II
Product code
KNT
Recalls
None
Predicates
2

Its longest line of descent runs back 4 generations to K813526 (1982). 7 ancestors in all. 4 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2009: 1 other ancestor2004: 1 other ancestor1984: 1 other ancestor2014: 2 descendants cleared2016: 1 descendant cleared2021: 1 descendant clearedK813526 · Fecal Sanitary Tube · Leon'S Fecal Sanitary Tub Mfg. · 1982K012113 · Indwelling Fecal Management System · Bowel Management Systems, LLC · 2002K023344 · Indwelling Fecal Management System-Non-Sterile · Bowel Management Systems, LLC · 2002K073598 · Bard Dignicare Stool Management System · C.R. Bard, Inc. · 200819801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 1 other ancestor3 generations back: 1 other ancestor 1 generation forward: 2 descendants2 generations forward: 1 descendant3 generations forward: 1 descendant K073598 · Bard Dignicare Stool Management System · C.R. Bard, Inc. · 2008K023344 · Indwelling Fecal Management System-Non-Sterile · Bowel Management Systems, LLC · 2002K012113 · Indwelling Fecal Management System · Bowel Management Systems, LLC · 2002K813526 · Fecal Sanitary Tube · Leon'S Fecal Sanitary Tub Mfg. · 19820
  1. Root · 4 generations backK813526 Fecal Sanitary TubeLeon'S Fecal Sanitary Tub Mfg. · 1982
  2. 3 generations backK012113 Indwelling Fecal Management SystemBowel Management Systems, LLC · 2002
  3. 2 generations backK023344 Indwelling Fecal Management System-Non-SterileBowel Management Systems, LLC · 2002
  4. 1 generation backK073598 Bard Dignicare Stool Management SystemC.R. Bard, Inc. · 2008
  5. This deviceK102391 Bard Dignishield Stool Management SystemC.R. Bard, Inc. · 2010
  6. Descendant · cites it directly · 2 of its ownK133465 Consure Stool Management SystemConsure Medical Pvt, Ltd. · 2014
  7. Descendant · 2 generations on · 1 of its ownK153506 Qora AIM Stool Management Kit, Qora Aeon Stool Management Kit, Qora…Consure Medical Pvt, Ltd. · 2016
  8. Descendant · 3 generations on · 0 of its ownK212444 Qora Stool Management KitCm Technologies, Inc. · 2021
  9. Descendant · cites it directly · 0 of its ownK133251 Bard Dignishield Stool Management SystemC.R. Bard, Inc. · 2014

Most influential descendants

Showing 4 of 4 · See all
  • K133465Consure Stool Management SystemConsure Medical Pvt, Ltd. · 2014 · cites it directly2descendants
  • K153506Qora AIM Stool Management Kit, Qora Aeon Stool Management Kit, Qora Arida Stool…Consure Medical Pvt, Ltd. · 2016 · 2 generations on1descendant
  • K212444Qora Stool Management KitCm Technologies, Inc. · 2021 · 3 generations on0descendants
  • K133251Bard Dignishield Stool Management SystemC.R. Bard, Inc. · 2014 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K813526Fecal Sanitary TubeLeon'S Fecal Sanitary Tub Mfg.1982—
−3K012113Indwelling Fecal Management SystemBowel Management Systems, LLC2002—
−2K023344Indwelling Fecal Management System-Non-SterileBowel Management Systems, LLC2002—
−1K073598Bard Dignicare Stool Management SystemC.R. Bard, Inc.2008—
0 (this device)K102391Bard Dignishield Stool Management SystemC.R. Bard, Inc.2010—
+1K133465Consure Stool Management SystemConsure Medical Pvt, Ltd.2014—
+2K153506Qora AIM Stool Management Kit, Qora Aeon Stool Management Kit, Qora Arida…Consure Medical Pvt, Ltd.2016—
+3K212444Qora Stool Management KitCm Technologies, Inc.2021—
+1K133251Bard Dignishield Stool Management SystemC.R. Bard, Inc.2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198410
200410
200910

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201420
201610
202110
FIG. 1 — Lineage of K102391, 1982–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KNT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KNT device

  1. #1 K261890 52Fr ViSiGi LUX™; 52Fr ViSiGi 3D®score 12.7 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K073598Bard Dignicare Stool Management System
Summary page 1
…ulation: 21 CFR § 876.5980 Regulatory Class: 11 Product Code: 78 KNT - Gastrointestinal tube and accessories Predicate Device(s): BARD® DigniCare™ Stool C. R. Bard, [nc. K073598 Management System ActiFlo™ Indwelling Catheter Hollister Inc. K083153 System Kit Device Description: The BARD® DigniShield™ Stoo…
C.R. Bard, Inc.2008—
*K083153Actiflo Indwelling Bowel Catheter System Kit, Models: 32004, 32005, 32006, 32007
Summary page 1
…Gastrointestinal tube and accessories Predicate Device(s): BARD® DigniCare™ Stool C. R. Bard, [nc. K073598 Management System ActiFlo™ Indwelling Catheter Hollister Inc. K083153 System Kit Device Description: The BARD® DigniShield™ Stool Management System is sold as a tray (kit). The catheter portion of…
Hollister, Inc.2009—

Also cleared against K073598: 1 other device →

What descends from it? (4)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K133465Consure Stool Management SystemConsure Medical Pvt, Ltd.20142
K133251Bard Dignishield Stool Management SystemC.R. Bard, Inc.20140

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 28 years and passes through 3 companies; a new generation was cleared every 5.6 years on median.
  • 1 of the 7 ancestors has a recall of any class.
  • Of its descendants, K133465 (Consure Medical Pvt, Ltd., 2014) has gone furthest, with 2 descendants of its own.
  • 1 other device also cites its predicate K073598.

How does its category compare?

All KNT devices

KNT Tubes, Gastrointestinal (And Accessories): FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · KNT

4in 2025

2007: 102008: 102009: 112010: 122011: 72012: 122013: 72014: 162015: 102016: 62017: 92018: 72019: 102020: 52021: 62022: 72023: 52024: 92025: 42026 (partial year): 3
2007high 16 (2014) · low 4 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KNT

136in 2025

2007: 118 days median2008: 115 days median2009: 102 days median2010: 104 days median2011: 211 days median2012: 107 days median2013: 128 days median2014: 259 days median2015: 140 days median2016: 99 days median2017: 247 days median2018: 149 days median2019: 126 days median2020: 102 days median2021: 121 days median2022: 110 days median2023: 162 days median2024: 103 days median2025: 136 days median2026 (partial year): 105 days median
2007high 259 (2014) · low 99 (2016)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KNT

13in 2025

2007: 12008: 822009: 92010: 32011: 22012: 12015: 12016: 32017: 42018: 22019: 22020: 12021: 22022: 1, 1 Class I2023: 22025: 132026 (partial year): 20
2007high 82 (2008) · low 0 (2013)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · KNT

1,451in 2025

2007: 3002008: 8672009: 8182010: 5172011: 5312012: 5282013: 7472014: 1,0302015: 1,0482016: 1,2512017: 1,6722018: 1,9012019: 1,8382020: 1,6412021: 1,6552022: 1,6502023: 1,8632024: 1,3442025: 1,451
2007high 1,901 (2018) · low 300 (2007)2025

MAUDE reports naming product code KNT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007101181300
20081011582867
2009111029818
2010121043517
201172112531
2012121071528
201371280747
20141625901,030
20151014011,048
201669931,251
2017924741,672
2018714921,901
20191012621,838
2020510211,641
2021612121,655
202271101 (1)1,650
2023516221,863
2024910301,344
20254136131,451
2026310520—

What is it indicated for?

The BARD® DigniShield™ Stool Management System is intended for

fecal management by diverting and collecting liquid or semi-liquid stool to minimize skin

contact in bedridden patients.

Adult Use Only

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K102391: Bard Dignishield Stool Management System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K102391

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026