510(k) Report

510(k) · Cleared

Cleared

Matryx Interference Screw (5.0-6.5MM)

K102410510(k) TraditionalCleared Dec 21, 2010119-day reviewClass II21 CFR 888.3040

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Conmed Linvatec · HWC Screw, Fixation, Bone

Cleared on Dec 21, 2010 as substantially equivalent to K032894 (Linvatec Biomaterials, Inc., 2004) and 3 other predicates after a 119-day review. Its family tree reaches back 8 generations to 1994. 2 later devices descend from it.

Decided
Dec 21, 2010
Review
119 days
Class
Class II
Product code
HWC
Recalls
None
Predicates
4

Its longest line of descent runs back 8 generations to K933738 (1994). 38 ancestors in all, the oldest K895711 (1990). 2 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2007: 1 other ancestor2006: 1 other ancestor2004: 1 other ancestor2001: 3 other ancestors2000: 2 other ancestors1998: 4 other ancestors1995: 4 other ancestors1994: 2 other ancestors2002: 1 other ancestor1999: 4 other ancestors1997: 1 other ancestor1996: 5 other ancestors1990: 1 other ancestor2012: 2 descendants clearedK933738 · M. Kurosaka Interference Fixation Screw · Depuy, Inc. · 1994 · recalledK955733 · Hyloc Interference Screw (Cannulated)/(Non-Cannulated) · Depuy, Inc. · 1996×3: 3 generations cleared close together, K980440 (1998), K981670 (1998), K982662 (1998) K993073 · Smart Screw Acl Models 237020, 237025, 237030, 238020, 238025, 238030, 239020, 239025, 239030 · Bionx Implants, Ltd. · 1999K032894 · Osteo Acl Screw Model;237020T, 237025T, 237030T, 238020T, 238025T, 238030T, 239020T, 239025T, 239030T, 231020T, 231025T, · Linvatec Biomaterials, Inc. · 2004K052080 · Matryx Interference Screw · Linvatec Biomaterials, Inc. · 20051990200020102020
  1. Root · 8 generations backK933738 M. Kurosaka Interference Fixation ScrewDepuy, Inc. · 1994 · Recalled
  2. 7 generations backK955733 Hyloc Interference Screw (Cannulated)/(Non-Cannulated)Depuy, Inc. · 1996
  3. 6 generations backK980440 Depuy Orthotech Phantom Sof-Thread Soft Tissue Interference ScrewDepuy, Inc. · 1998
  4. 5 generations backK981670 Depuy Profile Round Head Interference Screw and Depuy Phantom…Depuy, Inc. · 1998
  5. 4 generations backK982662 Depuy Profile Round Head Interference Screw, Depuy Phantom…DePuy Orthopaedics, Inc. · 1998 · Recalled
  6. 3 generations backK993073 Smart Screw Acl Models 237020, 237025, 237030, 238020, 238025…Bionx Implants, Ltd. · 1999
  7. 2 generations backK032894 Osteo Acl Screw Model;237020T, 237025T, 237030T, 238020T, 238025T…Linvatec Biomaterials, Inc. · 2004
  8. 1 generation backK052080 Matryx Interference ScrewLinvatec Biomaterials, Inc. · 2005
  9. This deviceK102410 Matryx Interference Screw (5.0-6.5MM)Conmed Linvatec · 2010
  10. Descendant · cites it directly · 1 of its ownK120589 Milagro Interference ScrewsDepuy Mitek, A Johnson & Johnson Company · 2012
  11. Descendant · 2 generations on · 0 of its ownK122869 Milagro Interference ScrewsDepuy Mitek, A Johnson & Johnson Company · 2012

Most influential descendants

Showing 2 of 2 · See all
  • K120589Milagro Interference ScrewsDepuy Mitek, A Johnson & Johnson Company · 2012 · cites it directly1descendant
  • K122869Milagro Interference ScrewsDepuy Mitek, A Johnson & Johnson Company · 2012 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K933738M. Kurosaka Interference Fixation ScrewDepuy, Inc.19942
−7K955733Hyloc Interference Screw (Cannulated)/(Non-Cannulated)Depuy, Inc.1996—
−6K980440Depuy Orthotech Phantom Sof-Thread Soft Tissue Interference ScrewDepuy, Inc.1998—
−5K981670Depuy Profile Round Head Interference Screw and Depuy Phantom Resorbable…Depuy, Inc.1998—
−4K982662Depuy Profile Round Head Interference Screw, Depuy Phantom Resorbable…DePuy Orthopaedics, Inc.19984
−3K993073Smart Screw Acl Models 237020, 237025, 237030, 238020, 238025, 238030, 239020…Bionx Implants, Ltd.1999—
−2K032894Osteo Acl Screw Model;237020T, 237025T, 237030T, 238020T, 238025T, 238030T…Linvatec Biomaterials, Inc.2004—
−1K052080Matryx Interference ScrewLinvatec Biomaterials, Inc.2005—
0 (this device)K102410Matryx Interference Screw (5.0-6.5MM)Conmed Linvatec2010—
+1K120589Milagro Interference ScrewsDepuy Mitek, A Johnson & Johnson Company2012—
+2K122869Milagro Interference ScrewsDepuy Mitek, A Johnson & Johnson Company2012—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199010
199420
199540
199650
199710
199840
199940
200020
200130
200210
200410
200610
200710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201220
FIG. 1 — Lineage of K102410, 1994–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HWC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HWC device

  1. #1 K203011 Monster Screw Systemscore 22.2 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K032894Osteo Acl Screw Model;237020T, 237025T, 237030T, 238020T, 238025T, 238030T, 239020T…
Summary page 1
…evices Device Name: Osteo AOIL Screw Company Name: Linvatec Biomnaterials Ltd. 510O(k) #: K032894 Device Name: Matryx Interference Screw Company Name: Linvatec Biomnaterials L…
Linvatec Biomaterials, Inc.2004—
*K052080Matryx Interference Screw
Summary page 1
…Device Name: Matryx Interference Screw Company Name: Linvatec Biomnaterials Ltd. 510O(k) #: K052080 Device Name: MILAGRO Interference Screw Company Name: Depuy Mitek 510O(k)…
Linvatec Biomaterials, Inc.2005—
*K060830Milagro Interference Screw
Summary page 1
…K052080 Device Name: MILAGRO Interference Screw Company Name: Depuy Mitek 510O(k) #: K060830 - ~hIZWD~mZ/2) riL [I NV AT E C 11311…
Depuy Mitek, A Johnson & Johnson Company2006—
*K071091Modification to Bilok Screw
Summary page 2
…464 * vvw.inats~m Device Name: Rilok Screw Company Name: Biocomposites Ltd 510O(k) #: K071091 E. Device Description The Genesys Matryx is a threaded, cannulated, bioabsorbable interference screw composed of ultra-high st…
Biocomposites, Ltd.2007—

Also cleared against K032894: 2 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K120589Milagro Interference ScrewsDepuy Mitek, A Johnson & Johnson Company20121

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 5 companies; a new generation was cleared every 1.4 years on median.
  • 3 of the 38 ancestors have a recall of any class.
  • Of its descendants, K120589 (Depuy Mitek, A Johnson & Johnson Company, 2012) has gone furthest, with 1 descendant of its own.
  • 2 other devices also cite its predicate K032894.

How does its category compare?

All HWC devices

HWC Screw, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · HWC

15in 2025

2007: 352008: 332009: 272010: 232011: 352012: 202013: 252014: 312015: 412016: 262017: 402018: 202019: 302020: 282021: 262022: 262023: 242024: 172025: 152026 (partial year): 21
2007high 41 (2015) · low 15 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HWC

111in 2025

2007: 77 days median2008: 76 days median2009: 113 days median2010: 110 days median2011: 88 days median2012: 99 days median2013: 90 days median2014: 88 days median2015: 85 days median2016: 131 days median2017: 127 days median2018: 106 days median2019: 108 days median2020: 75 days median2021: 84 days median2022: 167 days median2023: 104 days median2024: 90 days median2025: 111 days median2026 (partial year): 125 days median
2007high 167 (2022) · low 75 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HWC

1in 2025

2007: 252008: 332009: 292010: 72011: 122012: 302013: 142014: 22015: 52016: 42017: 42018: 12019: 52020: 42021: 22022: 132025: 12026 (partial year): 2
2007high 33 (2008) · low 0 (2023)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HWC

2,893in 2025

2007: 6692008: 6602009: 6512010: 7652011: 1,1042012: 3,3392013: 3,8502014: 2,5492015: 2,7112016: 2,2852017: 2,5612018: 3,6622019: 5,4632020: 4,8202021: 4,4462022: 3,9342023: 3,7182024: 3,5752025: 2,893
2007high 5,463 (2019) · low 651 (2009)2025

MAUDE reports naming product code HWC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007357725669
2008337633660
20092711329651
2010231107765
20113588121,104
20122099303,339
20132590143,850
2014318822,549
2015418552,711
20162613142,285
20174012742,561
20182010613,662
20193010855,463
2020287544,820
2021268424,446
202226167133,934
20232410403,718
2024179003,575
20251511112,893
2026211252—

What is it indicated for?

The Genesys Matryxtm is for attaching soft tissue to bone in orthopedic surgical procedures. Genesys Matryx TM is intended to be used for interference fixation of soft tissue (including ligaments or tendons) to bone, where the implant sizes offered are patient appropriate. The implant operates in conjunction with appropriate postoperative immobilization, throughout the healing period, to attach soft tissue to bone.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K102410: Matryx Interference Screw (5.0-6.5MM).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K102410

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026