510(k) · Cleared
ClearedEtest Telavancin in 0.002-32 UG/ML and 0.016-256 UG/ML
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Biomerieux S.A. · JWY Manual Antimicrobial Susceptibility Test Systems
Cleared on May 16, 2011 after a 255-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- May 16, 2011
- Review
- 255 days
- Class
- Class II
- Product code
- JWY
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JWY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JWY device
- #1 K260447 ETEST Gepotidacin (GEP) (0.016-256 µg/mL)score 12.7 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All JWY devicesJWY Manual Antimicrobial Susceptibility Test Systems: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.
FDA decisions per year · JWY
14in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JWY
106in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JWY
31in 2022
Class I (13 since 2007) Class II/III not classified
Adverse event reports per year · JWY
1in 2024
MAUDE reports naming product code JWY, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 6 | 85 | 1 | 1 |
| 2009 | 2 | — | 0 | 1 |
| 2010 | 4 | 73 | 0 | 0 |
| 2011 | 4 | 125 | 3 | 0 |
| 2012 | 1 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 6 | 106 | 5 | 4 |
| 2015 | 9 | 90 | 6 (4) | 11 |
| 2016 | 4 | 88 | 0 | 20 |
| 2017 | 14 | 61 | 2 | 9 |
| 2018 | 12 | 51 | 0 | 13 |
| 2019 | 18 | 60 | 0 | 10 |
| 2020 | 5 | 66 | 0 | 20 |
| 2021 | 5 | 266 | 0 | 41 |
| 2022 | 0 | — | 31 (9) | 11 |
| 2023 | 7 | 85 | 0 | 9 |
| 2024 | 6 | 90 | 0 | 1 |
| 2025 | 14 | 106 | 0 | 0 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
This submission is for Etest® Telavancin for MIC determinations across 0.002-32 µg/mL and 0.016-256 µg/mL with Staphylococcus aureus (including methicillin-resistant isolates), Enterococcus faecalis (vancomycin-susceptible isolates only), Streptococcus pyogenes, Streptococcus agalactiae and Streptococcus anginosus group Etest® is a quantitative technique for determination of antimicrobial susceptibility of both non-fastidious Gram negative and Gram…
Read the full statement (108 words)
This submission is for Etest® Telavancin for MIC determinations across 0.002-32 µg/mL and 0.016-256 µg/mL with Staphylococcus aureus (including methicillin-resistant isolates), Enterococcus faecalis (vancomycin-susceptible isolates only), Streptococcus pyogenes, Streptococcus agalactiae and Streptococcus anginosus group
Etest® is a quantitative technique for determination of antimicrobial susceptibility of both non-fastidious Gram negative and Gram positive aerobic bacteria such as Enterobacteriaceae, Pseudomonas, Staphylococcus and Enterococcus species and fastidious bacteria, such as anaerobes, N. gonorrhoeae, S. pneumoniae, Streptococcus and Haemophilus species. The system comprises a predefined antibiotic gradient which is used to determine the Minimum Inhibitory Concentration (MIC) in µg/mL of different antimicrobial agents against microorganisms as tested on agar using overnight incubation.
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K102535 · printed Nov 6, 2026
Cite this page
510(k) Report. “K102535: Etest Telavancin in 0.002-32 UG/ML and 0.016-256 UG/ML.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K102535
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026