Trophon

K103059510(k) TraditionalCleared Feb 24, 2011132-day reviewClass II21 CFR 892.1570Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Nanosonics Limited · OUJ High Level Disinfection Reprocessing Instrument For Ultrasonic Transducers, Mist

Cleared on Feb 24, 2011 as substantially equivalent to K051305 (Cs Medical, LLC, 2005) and 1 other predicate after a 132-day review. Its family tree reaches back 2 generations to 1994. 3 later devices descend from it. It has been recalled once.

Decided
Feb 24, 2011
Review
132 days
Class
Class II
Product code
OUJ
Recalls
1
Predicates
2

Its longest line of descent runs back 2 generations to K924334 (1994). 6 ancestors in all, the oldest K914145 (1994). 3 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2005: 1 other ancestor2000: 1 other ancestor1995: 1 other ancestor1994: 1 other ancestor2018: 1 descendant cleared2024: 1 descendant cleared2025: 1 descendant clearedK924334 · Cidex Formula 7* Long-Life Activated Dialdehyde · Johnson & Johnson Medical, Inc. · 1994K970230 · Sporox · Reckitt Benckiser, Inc. · 19971990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 3 other ancestors 1 generation forward: 1 descendant2 generations forward: 2 descendants K970230 · Sporox · Reckitt Benckiser, Inc. · 1997K924334 · Cidex Formula 7* Long-Life Activated Dialdehyde · Johnson & Johnson Medical, Inc. · 19940
  1. Root · 2 generations backK924334 Cidex Formula 7* Long-Life Activated DialdehydeJohnson & Johnson Medical, Inc. · 1994
  2. 1 generation backK970230 SporoxReckitt Benckiser, Inc. · 1997
  3. This deviceK103059 TrophonNanosonics Limited · 2011
  4. Descendant · cites it directly · 2 of its ownK173865 trophon2Nanosonics Limited · 2018
  5. Descendant · 2 generations on · 0 of its ownK250434 trophon2Nanosonics · 2025
  6. Descendant · 2 generations on · 0 of its ownK241536 trophon Wireless Ultrasound Probe HolderNanosonics Limited · 2024

Most influential descendants

Showing 3 of 3 · See all
  • K173865trophon2Nanosonics Limited · 2018 · cites it directly2descendants
  • K250434trophon2Nanosonics · 2025 · 2 generations on0descendants
  • K241536trophon Wireless Ultrasound Probe HolderNanosonics Limited · 2024 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K924334Cidex Formula 7* Long-Life Activated DialdehydeJohnson & Johnson Medical, Inc.1994—
−1K970230SporoxReckitt Benckiser, Inc.1997—
0 (this device)K103059TrophonNanosonics Limited2011—
+1K173865trophon2Nanosonics Limited2018—
+2K250434trophon2Nanosonics2025—
+2K241536trophon Wireless Ultrasound Probe HolderNanosonics Limited2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199510
200010
200510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201810
202410
202510
FIG. 1 — Lineage of K103059, 1994–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OUJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OUJ device

  1. #1 K250434 trophon2score 10.7 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K051305CS Medical TD-100 Transesophageal Probe Disinfector, Model TD-100, CS Medical TD-5…
Summary page 1
…: 21 CFR Sec. 892.1570 Diagnostic ultrasonic transducer (accessory to) Product Code: F ok Regulatory Class: II Predicate Devices: CS Medical TD-100 (K051305) Reckitt & Colman SporoX TM (K970230) Date Prepared: February 16, 2011 Description of the Dev…
Cs Medical, LLC2005—
*K970230Sporox
Summary page 1
…ssory to) Product Code: F ok Regulatory Class: II Predicate Devices: CS Medical TD-100 (K051305) Reckitt & Colman SporoX TM (K970230) Date Prepared: February 16, 2011 Description of the Device: The Nanosonics Trophon EPR is a software controlled devi…
Reckitt Benckiser, Inc.1997—

Also cleared against K051305: 2 other devices →

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K173865trophon2Nanosonics Limited20182

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 25, 2022Class IIZ-1602-2022Environmental controlFacility Temperature excursions (from June 2021-August 2021) prior to delivery; exposure to higher temperatures may have impacted product effectiveness. All lots received between 06/01/21-9/30/21.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 3 companies; a new generation was cleared every 13.3 years on median.
  • 1 of the 6 ancestors has a recall of any class.
  • Of its descendants, K173865 (Nanosonics Limited, 2018) has gone furthest, with 2 descendants of its own.
  • 2 other devices also cite its predicate K051305.

How does its category compare?

All OUJ devices

OUJ High Level Disinfection Reprocessing Instrument For Ultrasonic Transducers, Mist: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · OUJ

1in 2025

2011: 12018: 12024: 12025: 1
2007high 1 (2011) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OUJ

Too few OUJ 510(k)s in any year since 2007 to give a median.

Recalls per year · OUJ

No recall names OUJ since 2007.

Adverse event reports per year · OUJ

1in 2025

2014: 12017: 12018: 12021: 12023: 12025: 1
2007high 1 (2014) · low 0 (2007)2025

MAUDE reports naming product code OUJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20111—00
20120—00
20130—00
20140—01
20150—00
20160—00
20170—01
20181—01
20190—00
20200—00
20210—01
20220—00
20230—01
20241—00
20251—01
20260—0—

What is it indicated for?

The Trophon EPIR is designed to provide High-Level Disinfection of ultrasound transducers. The system uses the Trophon Disinfectant which is intended to be used exclusively with the Trophon EPR device. The Trophon Disinfectant is intended for use as a High-Level Disinfectant to be used exclusively with the Trophon EPR for the High-Level Disinfection of ultrasound transducers. The Trophon EPR is suitable for use in general hospital and health care…

Read the full statement (123 words)

The Trophon EPIR is designed to provide High-Level Disinfection of ultrasound transducers. The system uses the Trophon Disinfectant which is intended to be used exclusively with the Trophon EPR device.

The Trophon Disinfectant is intended for use as a High-Level Disinfectant to be used exclusively with the Trophon EPR for the High-Level Disinfection of ultrasound transducers.

The Trophon EPR is suitable for use in general hospital and health care facilities by trained personnel.

The Trophon EPR system consists of a multiple use instrument combined with a single use disinfectant, delivered from a multi-dose cartridge.

The Trophon Disinfectant should be used with the following contact conditions:

Minimum Operational Cycle Time: 7 minutes

Minimum Concentration: 31.5%

Minimum Disinfectant Dose: 1.0 g

Minimum Chamber Temperature: 560C

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K103059: Trophon.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K103059

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026