510(k) Report

510(k) · Cleared

Cleared

Jbaids Q Fever Detection Kit

K103207510(k) TraditionalCleared May 20, 2011200-day reviewClass I21 CFR 866.3500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Idaho Technology, Inc. · OVF Assay, Direct, Nucleic Acid Amplification, Q Fever

Cleared on May 20, 2011 as substantially equivalent to K922374 (Hillcrest Biologicals, 1992) and 1 other predicate after a 200-day review. Its family tree reaches back 1 generation to 1992.

Decided
May 20, 2011
Review
200 days
Class
Class I
Product code
OVF
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K922374 (1992). 2 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 1992: 1 other ancestorK922374 · Q Fever Igm Ifa Test · Hillcrest Biologicals · 199219901995200020052010
Other ancestors, by generation 1 generation back: 1 other ancestor K922374 · Q Fever Igm Ifa Test · Hillcrest Biologicals · 19920
  1. Root · 1 generation backK922374 Q Fever Igm Ifa TestHillcrest Biologicals · 1992
  2. This deviceK103207 Jbaids Q Fever Detection KitIdaho Technology, Inc. · 2011
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K922374Q Fever Igm Ifa TestHillcrest Biologicals1992—
0 (this device)K103207Jbaids Q Fever Detection KitIdaho Technology, Inc.2011—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199210
FIG. 1 — Lineage of K103207, 1992–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OVF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K922374Q Fever Igm Ifa Test
Summary page 4
…under K05 1713. The predicate for the JBAIDS Q Fever Detection Kit is the Focus Diagnostics 1gM and IgG IFA tests cleared under K922374 and K91 3906. The following table compares the JBAIDS Q Fever Detection System with the p…
Hillcrest Biologicals1992—
*K913906Q Fever Igg Ifa Test
Summary page 4
…713. The predicate for the JBAIDS Q Fever Detection Kit is the Focus Diagnostics 1gM and IgG IFA tests cleared under K922374 and K91 3906. The following table compares the JBAIDS Q Fever Detection System with the predicate test…
Hillcrest Biologicals1992—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.

How does its category compare?

All OVF devices

OVF Assay, Direct, Nucleic Acid Amplification, Q Fever: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · OVF

1in 2011

2011: 1
2007high 1 (2011) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OVF

Too few OVF 510(k)s in any year since 2007 to give a median.

Recalls per year · OVF

No recall names OVF since 2007.

Adverse event reports per year · OVF

No MAUDE report names OVF since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20111—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The Joint Biological Agent Identification and Diagnostic System (JBAIDS) Q Fever Detection Kit is a qualitative real-time polymerase chain reaction (PCR) test kit intended to identify and detect target DNA sequence from Coxiella burnetii in serum collected from individuals suspected of having acute Q fever, typically 7-10 days after onset of symptoms or before antibody formation. This in vitro diagnostic (IVD) test is intended to aid in the diagnosis of…

Read the full statement (363 words)

The Joint Biological Agent Identification and Diagnostic System (JBAIDS) Q Fever Detection Kit is a qualitative real-time polymerase chain reaction (PCR) test kit intended to identify and detect target DNA sequence from Coxiella burnetii in serum collected from individuals suspected of having acute Q fever, typically 7-10 days after onset of symptoms or before antibody formation. This in vitro diagnostic (IVD) test is intended to aid in the diagnosis of Q fever in individuals presenting with signs and symptoms of acute Q fever when used in conjunction with other clinical and laboratory findings. This kit is only intended to aid in the diagnosis of Q fever of patients presenting in the acute stage of the disease. Negative results do not preclude C. burnetii infection and should not be used as the sole basis for diagnosis, treatment or other management decisions.

The JBAIDS Q Fever assay is run on the JBAIDS instrument using the Diagnostic Wizard. Results are for the presumptive identification of C. burnetli in conjunction with serology and/or other laboratory tests. The following considerations also apply:

* The diagnosis of acute Q fever must be made based on history, signs, symptoms, exposure likelihood, and other laboratory evidence, in addition to the identification of C burnetii from serum specimens.

* Sensitivity is decreased by -25-40%, with no change in specificity, if the sample is collected after the patient has formed specific antibodies to C burnetii, typically 7- 10 days after onset of symptoms.

* The definitive identification of C burnetii from serum specimens requires additional testing and confirmation procedures in consultation with public health or other authorities for whom reports are required.

The test performance characteristics for this system were established with banked, frozen serum specimens that were sequentially received during a specified time period. The safety and effectiveness of other types of tests or sample types have not been established.

All users, analysts, and any person reporting diagnostic results from use of this device should be trained to perform and interpret the results from this procedure by JBAIDS instructors or designees prior to use. Use of this device is limited to designated Department of Defense (DoD) laboratories equipped with the JBAIDS instruments.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K103207: Jbaids Q Fever Detection Kit.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K103207

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026