510(k) Report

510(k) · Cleared

Cleared

Essential Mri Patient Monitor

K103700510(k) SpecialCleared Mar 15, 201185-day reviewClass II21 CFR 870.2700

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Invivo Corporation · DQA Oximeter

Cleared on Mar 15, 2011 as substantially equivalent to K090785 (Invivo Corp., 2009) after an 85-day review. Its family tree reaches back 29 generations to 1994.

Decided
Mar 15, 2011
Review
85 days
Class
Class II
Product code
DQA
Recalls
None
Predicates
1

Its longest line of descent runs back 29 generations to K941811 (1994). 194 ancestors in all, the oldest K832113 (1983). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2006: 5 other ancestors2005: 3 other ancestors2004: 15 other ancestors2002: 13 other ancestors2007: 1 other ancestor2003: 13 other ancestors2001: 7 other ancestors2000: 20 other ancestors1998: 14 other ancestors1995: 9 other ancestors1994: 3 other ancestors1999: 10 other ancestors1997: 8 other ancestors1996: 11 other ancestors1993: 6 other ancestors1992: 6 other ancestors1991: 7 other ancestors1990: 6 other ancestors1989: 3 other ancestors1988: 1 other ancestor1987: 2 other ancestors1983: 1 other ancestor1985: 1 other ancestorK941811 · HP M1175A, M1176A, Component Monitoring System · Hewlett-Packard Co. · 1994K960934 · HP M1205A Omnicare Component Monitor System Model 24 · Hewlett-Packard Co. · 1996×3: 3 generations cleared close together, K981376 (1999), K990125 (1999), K990972 (1999) ×3: 3 generations cleared close together, K013199 (2001), K020531 (2002), K021778 (2002) ×3: 3 generations cleared close together, K023871 (2002), K030038 (2003), K031481 (2003) K032858 · The Philips Intellivue MP40, MP50, MP60, MP70,and MP90 Patient Monitors, Release B.O. · Philips Medizin Systeme Boblingen GmbH · 2003×2: 2 generations cleared close together, K040304 (2004), K041235 (2004) ×11: 11 generations cleared close together, K042845 (2004), K050141 (2005), K050762 (2005), K051106 (2005), K052801 (2005), K053522 (2006), K060221 (2006), K060541 (2006), K061052 (2006), K061610 (2006), K063315 (2006) ×2: 2 generations cleared close together, K071426 (2007), K072070 (2007) K081937 · Picosat II and M3002A Multimeasurement and M1020B Plug-in Modules SPO2 Pulse Oximetry Module · Philips Medizin Systeme Boeblingen GmbH · 2008K090785 · Mri Compatible Patient Monitoring System, Model 865214 · Invivo Corp. · 2009 · recalled1980198519901995200020052010
Other ancestors, by generation 2 generations back: 1 other ancestor3 generations back: 6 other ancestors4 generations back: 14 other ancestors5 generations back: 34 other ancestors6 generations back: 33 other ancestors7 generations back: 26 other ancestors8 generations back: 16 other ancestors9 generations back: 14 other ancestors10 generations back: 12 other ancestors11 generations back: 8 other ancestors12 generations back: 1 other ancestor K090785 · Mri Compatible Patient Monitoring System, Model 865214 · Invivo Corp. · 2009 · recalledK081937 · Picosat II and M3002A Multimeasurement and M1020B Plug-in Modules SPO2 Pulse Oximetry Module · Philips Medizin Systeme Boeblingen GmbH · 2008K072070 · Philips MP2 and X2 Intellivue Patient Monitors · Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2007K071426 · MP2, X2, MP5, MP20, MP30, MP40, MP50, MP60, MP70, MP80, and MP90 Intellivue Patient Monitors · Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2007K063315 · Intellivue Patient Monitors, Models MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90 · Philips Medizin Systeme Boeblingen GmbH · 2006K061610 · Philips Model MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue Patient Monitors · Philips Medizin Systeme Boeblingen GmbH · 2006K061052 · The Philips Intellivue Patient Monitors, Models MP20,MP30,MP40,MP50,MP60,MP70,MP80,MP90 · Philips Medical Systems North America, Inc. · 2006K060541 · The Philips MP20,MP30,MP40,MP50,MP60,MP70,MP80 and MP90 Intellivue Atient Monitors · Philips Medizin Systeme Boblingen GmbH · 2006 · recalledK060221 · The Phillips, Model MP20,MP30,MP40,MP50,MP60,MP70,MP80,and MP90 Intellivue Patient Monitors · Philips Medizin Systeme Boeblingen GmbH · 2006K053522 · Philips MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue Patient Monitors, Release D.00 · Philips Medizin Systeme Boeblingen GmbH · 2006K052801 · Intellivue Patient Monitors with Release C.02, Models MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90 · Philips Medizin Systeme Boeblingen GmbH · 2005K051106 · The Philips MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue Patient Monitors · Philips Medizin Systeme Boeblingen GmbH · 2005K050762 · Philips Intellivue Patient Monitor, Models MP20, MP30, MP40, MP50, MP60, MP70 and MP90 · Philips Medizin Systeme Boeblingen GmbH · 2005K050141 · The Philips MP20, MP30, MP40, MP50, MP60, MP70 and MP90 Intellivue Patient Monitors · Philips Medizin Systeme Boeblingen GmbH · 2005K042845 · The Philips MP20, MP30, MP40, MP50, MP60, MP70, and MP90 Intellivue Patient Monitors · Philips Medizin Systeme Boblingen GmbH · 2004K041235 · Philips MP20, MP30, MP40, MP50. MP60, MP70 and MP90 Intellivue Patient Monitors · Philips Medizin Systeme Boeblingen GmbH · 2004K040304 · Philips Intellivue Patient Monitor, Models MP40 & MP50 · Philips Medizin Systeme Boeblingen GmbH · 2004K032858 · The Philips Intellivue MP40, MP50, MP60, MP70,and MP90 Patient Monitors, Release B.O. · Philips Medizin Systeme Boblingen GmbH · 2003K031481 · The Philips Intellivue MP60, MP70, and MP90 Patient Monitors, Release a.20 · Philips Medizin Systeme Boblingen GmbH · 2003K030038 · Philips MP60, MP70 and MP90 Intellivue Patient Monitors with Portal Technology and M3185 Opt C41 Wireless Bedside Adaptr · Philips Medical Systems, Inc. · 2003K023871 · M3046A (M2/M3/M4) Compact Portable Patient Monitor and MP60 & MP70 Intellivue Patient Monitor with Portal Technology · Philips Medical Systems · 2002K021778 · Philips Component Compact Monitor, Release a.04, Model #M1275B · Philips Medical Systems · 2002K020531 · Philips Multi-Parameter Module, Model M3001A; Philips Component Compact Monitor, Release a.02, Model M1275B · Philips Medical Systems · 2002K013199 · Philips Component Compact Monitor,Model M1275B, Philips Compenent Rack, Model M1276B · Philips Medical Systems, Inc. · 2001K990972 · HP Viridia Component Monitoring System, HP Viridia CMS 24/26, HP Viridia Multi-Measurement Server and Compact Portable T · Hewlett-Packard GmbH · 1999K990125 · HP Viridia Component Monitoring System, Model Rev. K · Hewlett-Packard GmbH · 1999K981376 · Hewlett-Packard M1205A Viridia 24 CT · Hewlett-Packard Co. · 1999K960934 · HP M1205A Omnicare Component Monitor System Model 24 · Hewlett-Packard Co. · 1996K941811 · HP M1175A, M1176A, Component Monitoring System · Hewlett-Packard Co. · 1994−25−20−15−10−50
  1. Root · 29 generations backK941811 HP M1175A, M1176A, Component Monitoring SystemHewlett-Packard Co. · 1994
  2. 25 generations between
  3. 3 generations backK072070 Philips MP2 and X2 Intellivue Patient MonitorsPhilips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2007
  4. 2 generations backK081937 Picosat II and M3002A Multimeasurement and M1020B Plug-in Modules…Philips Medizin Systeme Boeblingen GmbH · 2008
  5. 1 generation backK090785 Mri Compatible Patient Monitoring System, Model 865214Invivo Corp. · 2009 · Recalled
  6. This deviceK103700 Essential Mri Patient MonitorInvivo Corporation · 2011
Show all 29 generations
  1. Root · 29 generations backK941811 HP M1175A, M1176A, Component Monitoring SystemHewlett-Packard Co. · 1994
  2. 28 generations backK960934 HP M1205A Omnicare Component Monitor System Model 24Hewlett-Packard Co. · 1996
  3. 27 generations backK981376 Hewlett-Packard M1205A Viridia 24 CTHewlett-Packard Co. · 1999
  4. 26 generations backK990125 HP Viridia Component Monitoring System, Model Rev. KHewlett-Packard GmbH · 1999
  5. 25 generations backK990972 HP Viridia Component Monitoring System, HP Viridia CMS 24/26, HP…Hewlett-Packard GmbH · 1999
  6. 24 generations backK013199 Philips Component Compact Monitor,Model M1275B, Philips Compenent…Philips Medical Systems, Inc. · 2001
  7. 23 generations backK020531 Philips Multi-Parameter Module, Model M3001A; Philips Component…Philips Medical Systems · 2002
  8. 22 generations backK021778 Philips Component Compact Monitor, Release a.04, Model #M1275BPhilips Medical Systems · 2002
  9. 21 generations backK023871 M3046A (M2/M3/M4) Compact Portable Patient Monitor and MP60 & MP70…Philips Medical Systems · 2002
  10. 20 generations backK030038 Philips MP60, MP70 and MP90 Intellivue Patient Monitors with Portal…Philips Medical Systems, Inc. · 2003
  11. 19 generations backK031481 The Philips Intellivue MP60, MP70, and MP90 Patient Monitors…Philips Medizin Systeme Boblingen GmbH · 2003
  12. 18 generations backK032858 The Philips Intellivue MP40, MP50, MP60, MP70,and MP90 Patient…Philips Medizin Systeme Boblingen GmbH · 2003
  13. 17 generations backK040304 Philips Intellivue Patient Monitor, Models MP40 & MP50Philips Medizin Systeme Boeblingen GmbH · 2004
  14. 16 generations backK041235 Philips MP20, MP30, MP40, MP50. MP60, MP70 and MP90 Intellivue…Philips Medizin Systeme Boeblingen GmbH · 2004
  15. 15 generations backK042845 The Philips MP20, MP30, MP40, MP50, MP60, MP70, and MP90 Intellivue…Philips Medizin Systeme Boblingen GmbH · 2004
  16. 14 generations backK050141 The Philips MP20, MP30, MP40, MP50, MP60, MP70 and MP90 Intellivue…Philips Medizin Systeme Boeblingen GmbH · 2005
  17. 13 generations backK050762 Philips Intellivue Patient Monitor, Models MP20, MP30, MP40, MP50…Philips Medizin Systeme Boeblingen GmbH · 2005
  18. 12 generations backK051106 The Philips MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90…Philips Medizin Systeme Boeblingen GmbH · 2005
  19. 11 generations backK052801 Intellivue Patient Monitors with Release C.02, Models MP20, MP30…Philips Medizin Systeme Boeblingen GmbH · 2005
  20. 10 generations backK053522 Philips MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue Patient…Philips Medizin Systeme Boeblingen GmbH · 2006
  21. 9 generations backK060221 The Phillips, Model MP20,MP30,MP40,MP50,MP60,MP70,MP80,and MP90…Philips Medizin Systeme Boeblingen GmbH · 2006
  22. 8 generations backK060541 The Philips MP20,MP30,MP40,MP50,MP60,MP70,MP80 and MP90 Intellivue…Philips Medizin Systeme Boblingen GmbH · 2006 · Recalled
  23. 7 generations backK061052 The Philips Intellivue Patient Monitors, Models…Philips Medical Systems North America, Inc. · 2006
  24. 6 generations backK061610 Philips Model MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90…Philips Medizin Systeme Boeblingen GmbH · 2006
  25. 5 generations backK063315 Intellivue Patient Monitors, Models MP20, MP30, MP40, MP50, MP60…Philips Medizin Systeme Boeblingen GmbH · 2006
  26. 4 generations backK071426 MP2, X2, MP5, MP20, MP30, MP40, MP50, MP60, MP70, MP80, and MP90…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2007
  27. 3 generations backK072070 Philips MP2 and X2 Intellivue Patient MonitorsPhilips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2007
  28. 2 generations backK081937 Picosat II and M3002A Multimeasurement and M1020B Plug-in Modules…Philips Medizin Systeme Boeblingen GmbH · 2008
  29. 1 generation backK090785 Mri Compatible Patient Monitoring System, Model 865214Invivo Corp. · 2009 · Recalled
  30. This deviceK103700 Essential Mri Patient MonitorInvivo Corporation · 2011
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−29K941811HP M1175A, M1176A, Component Monitoring SystemHewlett-Packard Co.1994—
−28K960934HP M1205A Omnicare Component Monitor System Model 24Hewlett-Packard Co.1996—
−27K981376Hewlett-Packard M1205A Viridia 24 CTHewlett-Packard Co.1999—
−26K990125HP Viridia Component Monitoring System, Model Rev. KHewlett-Packard GmbH1999—
−25K990972HP Viridia Component Monitoring System, HP Viridia CMS 24/26, HP Viridia…Hewlett-Packard GmbH1999—
−24K013199Philips Component Compact Monitor,Model M1275B, Philips Compenent Rack, Model…Philips Medical Systems, Inc.2001—
−23K020531Philips Multi-Parameter Module, Model M3001A; Philips Component Compact…Philips Medical Systems2002—
−22K021778Philips Component Compact Monitor, Release a.04, Model #M1275BPhilips Medical Systems2002—
−21K023871M3046A (M2/M3/M4) Compact Portable Patient Monitor and MP60 & MP70 Intellivue…Philips Medical Systems2002—
−20K030038Philips MP60, MP70 and MP90 Intellivue Patient Monitors with Portal Technology…Philips Medical Systems, Inc.2003—
−19K031481The Philips Intellivue MP60, MP70, and MP90 Patient Monitors, Release a.20Philips Medizin Systeme Boblingen GmbH2003—
−18K032858The Philips Intellivue MP40, MP50, MP60, MP70,and MP90 Patient Monitors…Philips Medizin Systeme Boblingen GmbH2003—
−17K040304Philips Intellivue Patient Monitor, Models MP40 & MP50Philips Medizin Systeme Boeblingen GmbH2004—
−16K041235Philips MP20, MP30, MP40, MP50. MP60, MP70 and MP90 Intellivue Patient MonitorsPhilips Medizin Systeme Boeblingen GmbH2004—
−15K042845The Philips MP20, MP30, MP40, MP50, MP60, MP70, and MP90 Intellivue Patient…Philips Medizin Systeme Boblingen GmbH2004—
−14K050141The Philips MP20, MP30, MP40, MP50, MP60, MP70 and MP90 Intellivue Patient…Philips Medizin Systeme Boeblingen GmbH2005—
−13K050762Philips Intellivue Patient Monitor, Models MP20, MP30, MP40, MP50, MP60, MP70…Philips Medizin Systeme Boeblingen GmbH2005—
−12K051106The Philips MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue…Philips Medizin Systeme Boeblingen GmbH2005—
−11K052801Intellivue Patient Monitors with Release C.02, Models MP20, MP30, MP40, MP50…Philips Medizin Systeme Boeblingen GmbH2005—
−10K053522Philips MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue Patient Monitors…Philips Medizin Systeme Boeblingen GmbH2006—
−9K060221The Phillips, Model MP20,MP30,MP40,MP50,MP60,MP70,MP80,and MP90 Intellivue…Philips Medizin Systeme Boeblingen GmbH2006—
−8K060541The Philips MP20,MP30,MP40,MP50,MP60,MP70,MP80 and MP90 Intellivue Atient…Philips Medizin Systeme Boblingen GmbH20062
−7K061052The Philips Intellivue Patient Monitors, Models…Philips Medical Systems North America, Inc.2006—
−6K061610Philips Model MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue…Philips Medizin Systeme Boeblingen GmbH2006—
−5K063315Intellivue Patient Monitors, Models MP20, MP30, MP40, MP50, MP60, MP70, MP80…Philips Medizin Systeme Boeblingen GmbH2006—
−4K071426MP2, X2, MP5, MP20, MP30, MP40, MP50, MP60, MP70, MP80, and MP90 Intellivue…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN2007—
−3K072070Philips MP2 and X2 Intellivue Patient MonitorsPhilips Medizinsysteme Boeblingen GmbH, Cardiac AN2007—
−2K081937Picosat II and M3002A Multimeasurement and M1020B Plug-in Modules SPO2 Pulse…Philips Medizin Systeme Boeblingen GmbH2008—
−1K090785Mri Compatible Patient Monitoring System, Model 865214Invivo Corp.20096
0 (this device)K103700Essential Mri Patient MonitorInvivo Corporation2011—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198310
198510
198720
198810
198930
199060
199170
199260
199360
199430
199590
1996110
199780
1998140
1999100
2000200
200170
2002130
2003130
2004150
200530
200650
200710
FIG. 1 — Lineage of K103700, 1994–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQA device

  1. #1 K221282 Empatica Health Monitoring Platformscore 20.1 · 38 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K090785Mri Compatible Patient Monitoring System, Model 865214
Summary page 2
…nt for this device. The modified device is predicated from the MLII Patient Monitoring System (Model 865214) which received clearance to market under 510(k) K090785 on December 15, 2009. The cleared device consists of a processing unit, display, and wireless SP02 module which is di…
Invivo Corp.20096

Also cleared against K090785: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 10 companies; a new generation was cleared every 3 months on median.
  • 22 of the 194 ancestors have a recall of any class.
  • 3 other devices also cite its predicate K090785.

How does its category compare?

All DQA devices

DQA Oximeter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · DQA

15in 2025

2007: 202008: 222009: 352010: 292011: 152012: 142013: 152014: 112015: 132016: 142017: 92018: 182019: 192020: 152021: 102022: 202023: 132024: 142025: 152026 (partial year): 8
2007high 35 (2009) · low 9 (2017)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQA

182in 2025

2007: 122 days median2008: 97 days median2009: 117 days median2010: 127 days median2011: 195 days median2012: 120 days median2013: 182 days median2014: 175 days median2015: 158 days median2016: 246 days median2017: 200 days median2018: 260 days median2019: 158 days median2020: 126 days median2021: 174 days median2022: 265 days median2023: 317 days median2024: 285 days median2025: 182 days median2026 (partial year): 187 days median
2007high 317 (2023) · low 97 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQA

3in 2024

2007: 62008: 52009: 292010: 42011: 12014: 22015: 12018: 322024: 3
2007high 32 (2018) · low 0 (2012)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DQA

399in 2025

2007: 3252008: 3122009: 2812010: 1852011: 1642012: 3222013: 4682014: 1,1242015: 2,0822016: 1,7752017: 1,1902018: 6942019: 5482020: 4262021: 5532022: 4782023: 3922024: 5452025: 399
2007high 2,082 (2015) · low 164 (2011)2025

MAUDE reports naming product code DQA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007201226325
200822975312
20093511729281
2010291274185
2011151951164
2012141200322
2013151820468
20141117521,124
20151315812,082
20161424601,775
2017920001,190
20181826032694
2019191580548
2020151260426
2021101740553
2022202650478
2023133170392
2024142853545
2025151820399
202681870—

What is it indicated for?

The MRI Patient Monitor (Model 865353) is intended to monitor vital signs for patients undergoing MRI procedures. The MRI Patient Monitor (Model 865353) is intended for use by healthcare professionals.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K103700: Essential Mri Patient Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K103700

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026