510(k) Report

510(k) · Cleared

Cleared

CVM, Unconjugated Estriol (UE3) Calibration Verification Material

K110061510(k) AbbreviatedCleared Sep 21, 2011254-day reviewClass I21 CFR 862.1660

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Siemens Healthcare Diagnostics · JJX Single (Specified) Analyte Controls (Assayed And Unassayed)

Cleared on Sep 21, 2011 as substantially equivalent to K102904 (Siemens Healthcare Diagnostics, 2010) after a 254-day review. Its family tree reaches back 4 generations to 1995. 14 later devices descend from it.

Decided
Sep 21, 2011
Review
254 days
Class
Class I
Product code
JJX
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K950469 (1995). 14 later devices descend from it, 1 citing it directly.

  1. Root · 4 generations backK950469 Document Serum Multianalyte Calibration Verification Test SetCasco Standards · 1995
  2. 3 generations backK992034 Document Thyroid Cal*VerCasco-Nerl Diagnostics Corporation (Maine) · 1999
  3. 2 generations backK062501 Validate Thyroid Calibration Verification / Linearity Test Set…Maine Standards Co. · 2006
  4. 1 generation backK102904 Enhanced Estradiol (EE2) Master Curve MaterialSiemens Healthcare Diagnostics · 2010
  5. This deviceK110061 CVM, Unconjugated Estriol (UE3) Calibration Verification MaterialSiemens Healthcare Diagnostics · 2011
  6. Descendant · cites it directly · 13 of its ownK133128 Immulite 2000; HCG Calibration Verification Material, Insulin…Siemens Healthcare Diagnostics, Inc. · 2013
  7. Descendant · 2 generations on · 7 of its ownK140258 Immulite 2000 Dhea-SO4; Third Generation TSH and Intact PTH…Siemens Healthcare Diagnostics, Inc. · 2014
  8. Descendant · 2 generations on · 3 of its ownK140818 Immulite: 2000 Free T4 Calibration Verification Material, 2000 Igf-I…Siemens Healthcare Diagnostics, Inc. · 2014
  9. Descendant · 2 generations on · 2 of its ownK140541 Immulite 2000: C-Peptide Calibration Verification Material, SHBG…Siemens Healthcare Diagnostics, Inc. · 2014
  10. Descendant · 3 generations on · 1 of its ownK141444 Immulite 2000; Cortisol Calibration Verification Material, Folic…Siemens Healthcare Diagnostics, Inc. · 2014

Showing 5 of 14 descendants. See all descendants

Descendants cleared per year

2013: 12014: 82015: 5
2013high 8 (2014) · low 0 (2016)2026

Most influential descendants

Showing 5 of 14 · See all
  • K133128Immulite 2000; HCG Calibration Verification Material, Insulin Calibration Verification…Siemens Healthcare Diagnostics, Inc. · 2013 · cites it directly13descendants
  • K140258Immulite 2000 Dhea-SO4; Third Generation TSH and Intact PTH Calibration Verification…Siemens Healthcare Diagnostics, Inc. · 2014 · 2 generations on7descendants
  • K140818Immulite: 2000 Free T4 Calibration Verification Material, 2000 Igf-I Calibration…Siemens Healthcare Diagnostics, Inc. · 2014 · 2 generations on3descendants
  • K140541Immulite 2000: C-Peptide Calibration Verification Material, SHBG Calibration…Siemens Healthcare Diagnostics, Inc. · 2014 · 2 generations on2descendants
  • K141444Immulite 2000; Cortisol Calibration Verification Material, Folic Acid Calibration…Siemens Healthcare Diagnostics, Inc. · 2014 · 3 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K950469Document Serum Multianalyte Calibration Verification Test SetCasco Standards1995—
−3K992034Document Thyroid Cal*VerCasco-Nerl Diagnostics Corporation (Maine)1999—
−2K062501Validate Thyroid Calibration Verification / Linearity Test Set, Model 901Maine Standards Co.2006—
−1K102904Enhanced Estradiol (EE2) Master Curve MaterialSiemens Healthcare Diagnostics2010—
0 (this device)K110061CVM, Unconjugated Estriol (UE3) Calibration Verification MaterialSiemens Healthcare Diagnostics2011—
+1K133128Immulite 2000; HCG Calibration Verification Material, Insulin Calibration…Siemens Healthcare Diagnostics, Inc.2013—
+2K140258Immulite 2000 Dhea-SO4; Third Generation TSH and Intact PTH Calibration…Siemens Healthcare Diagnostics, Inc.2014—
+2K140818Immulite: 2000 Free T4 Calibration Verification Material, 2000 Igf-I…Siemens Healthcare Diagnostics, Inc.2014—
+2K140541Immulite 2000: C-Peptide Calibration Verification Material, SHBG Calibration…Siemens Healthcare Diagnostics, Inc.2014—
+3K141444Immulite 2000; Cortisol Calibration Verification Material, Folic Acid…Siemens Healthcare Diagnostics, Inc.2014—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
201480
201550
FIG. 1 — Lineage of K110061, 1995–2015Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JJX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K102904Enhanced Estradiol (EE2) Master Curve Material
Summary page 1
…l is for in vitro diagnostic use in the verification of calibration and reportable Range in the ADVIA Centaur®@ Enhanced Estradiol (eE2) assay cleared under 51l0k number K102904. G. Device Description: IMMULITE unconjugated Estriol assays are traceable to an internal standard and manufactured using quali…
Siemens Healthcare Diagnostics2010—

Also cleared against K102904: 2 other devices →

What descends from it? (14)

See all 14

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K133128Immulite 2000; HCG Calibration Verification Material, Insulin Calibration Verification…Siemens Healthcare Diagnostics, Inc.201313

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 4 companies; a new generation was cleared every 4.3 years on median.
  • None of the 4 ancestors has a recall.
  • Of its descendants, K133128 (Siemens Healthcare Diagnostics, Inc., 2013) has gone furthest, with 13 descendants of its own.
  • 2 other devices also cite its predicate K102904.

How does its category compare?

All JJX devices

JJX Single (Specified) Analyte Controls (Assayed And Unassayed): FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · JJX

2in 2017

2007: 62008: 82009: 172010: 242011: 192012: 152013: 192014: 222015: 112016: 62017: 2
2007high 24 (2010) · low 0 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JJX

31in 2016

2007: 53 days median2008: 52 days median2009: 80 days median2010: 80 days median2011: 62 days median2012: 40 days median2013: 37 days median2014: 30 days median2015: 65 days median2016: 31 days median
2007high 80 (2009) · low 30 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JJX

1in 2021

2007: 32008: 32010: 32011: 22014: 12015: 12016: 22018: 22021: 1
2007high 3 (2007) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JJX

22in 2025

2007: 22009: 12010: 62011: 622012: 322013: 512014: 482015: 672016: 372017: 192018: 352019: 822020: 772021: 432022: 242023: 222024: 302025: 22
2007high 82 (2019) · low 0 (2008)2025

MAUDE reports naming product code JJX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200765332
200885230
2009178001
2010248036
20111962262
20121540032
20131937051
20142230148
20151165167
2016631237
20172—019
20180—235
20190—082
20200—077
20210—143
20220—024
20230—022
20240—030
20250—022
20260—0—

What is it indicated for?

For in vitro diagnostic use as a control for calibration verification of the IMMULITE® Unconjugated Estriol (uE3) assays on the IMMULITE/IMMULITE 1000, 2000 systems.

The calibration verification material is assayed control with four levels. The analyte levels for IMMULITE 1000 are 0.00, 0.16, 2.70 and 11.2 ng/ml, and 0.00, 0.19, 2.90 and 12.00 for IMULITE 2000 systems. The matrix is estriol in processed horse serum.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K110061: CVM, Unconjugated Estriol (UE3) Calibration Verification Material.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K110061

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026