510(k) Report

510(k) · Cleared

Cleared

Polarcup Dual Mobility System

K110135510(k) TraditionalCleared Oct 14, 2011269-day reviewClass II21 CFR 888.3358

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Smith & Nephew, Inc. · LPH Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented

Cleared on Oct 14, 2011 as substantially equivalent to K070278 (Plus Orthopedics AG, 2007) and 1 other predicate after a 269-day review. Its family tree reaches back 3 generations to 1999. 14 later devices descend from it.

Decided
Oct 14, 2011
Review
269 days
Class
Class II
Product code
LPH
Recalls
None
Predicates
2

Its longest line of descent runs back 3 generations to K991990 (1999). 4 ancestors in all. 14 later devices descend from it, 7 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2007: 1 other ancestor2019: 2 descendants cleared2022: 2 descendants cleared2017: 1 descendant cleared2018: 1 descendant cleared2012: 1 descendant cleared2025: 2 descendants cleared2023: 2 descendants cleared2024: 2 descendants cleared2026: 1 descendant clearedK991990 · Tri-Polar System · Biomet, Inc. · 1999K070278 · Polarcup Dual Mobility System · Plus Orthopedics AG · 2007K083116 · Versafit Cup Double Mobility System · Medacta International S.A. · 2009 · recalled1995200020052010201520202025
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor 1 generation forward: 7 descendants2 generations forward: 7 descendants K083116 · Versafit Cup Double Mobility System · Medacta International S.A. · 2009 · recalledK070278 · Polarcup Dual Mobility System · Plus Orthopedics AG · 2007K991990 · Tri-Polar System · Biomet, Inc. · 19990
  1. Root · 3 generations backK991990 Tri-Polar SystemBiomet, Inc. · 1999
  2. 2 generations backK070278 Polarcup Dual Mobility SystemPlus Orthopedics AG · 2007
  3. 1 generation backK083116 Versafit Cup Double Mobility SystemMedacta International S.A. · 2009 · Recalled
  4. This deviceK110135 Polarcup Dual Mobility SystemSmith & Nephew, Inc. · 2011
  5. Descendant · cites it directly · 9 of its ownK171934 Birmingham Hip (BH) Dual Mobility InsertSmith & Nephew, Inc. · 2017
  6. Descendant · cites it directly · 5 of its ownK191002 OR3O Dual Mobility SystemSmith & Nephew, Inc. · 2019
  7. Descendant · cites it directly · 5 of its ownK122244 Polarcup Dual Mobility SystemSmith & Nephew, Inc. · 2012
  8. Descendant · cites it directly · 3 of its ownK220959 OR3O Dual Mobility SystemSmith & Nephew, Inc. · 2022
  9. Descendant · cites it directly · 3 of its ownK211176 Smith & Nephew Hip SystemsSmith & Nephew, Inc. · 2022 · Recalled

Showing 5 of 14 descendants. See all descendants

Descendants cleared per year

2012: 12017: 12018: 12019: 22022: 22023: 22024: 22025: 22026: 1
2012high 2 (2019) · low 0 (2013)2026

Most influential descendants

Showing 5 of 14 · See all
  • K171934Birmingham Hip (BH) Dual Mobility InsertSmith & Nephew, Inc. · 2017 · cites it directly9descendants
  • K191002OR3O Dual Mobility SystemSmith & Nephew, Inc. · 2019 · cites it directly5descendants
  • K122244Polarcup Dual Mobility SystemSmith & Nephew, Inc. · 2012 · cites it directly5descendants
  • K220959OR3O Dual Mobility SystemSmith & Nephew, Inc. · 2022 · cites it directly3descendants
  • K211176Smith & Nephew Hip SystemsSmith & Nephew, Inc. · 2022 · cites it directly3descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K991990Tri-Polar SystemBiomet, Inc.1999—
−2K070278Polarcup Dual Mobility SystemPlus Orthopedics AG2007—
−1K083116Versafit Cup Double Mobility SystemMedacta International S.A.20092
0 (this device)K110135Polarcup Dual Mobility SystemSmith & Nephew, Inc.2011—
+1K171934Birmingham Hip (BH) Dual Mobility InsertSmith & Nephew, Inc.2017—
+1K191002OR3O Dual Mobility SystemSmith & Nephew, Inc.2019—
+1K122244Polarcup Dual Mobility SystemSmith & Nephew, Inc.2012—
+1K220959OR3O Dual Mobility SystemSmith & Nephew, Inc.2022—
+1K211176Smith & Nephew Hip SystemsSmith & Nephew, Inc.20221

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201210
201710
201810
201920
202220
202320
202420
202520
202610
FIG. 1 — Lineage of K110135, 1999–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LPH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LPH device

  1. #1 K233498 Stryker Orthopaedics Hip Systems Labeling Updatescore 24.2 · 20 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K070278Polarcup Dual Mobility System
Summary page 1
…LPH, KWY', JDI Predicate Devices: POLARCUP Dual Mobility System 510(k): K070278 Product Codes: LPH, KWVY…
Plus Orthopedics AG2007—
*K083116Versafit Cup Double Mobility System
Summary page 1
…Codes: LPH, KWVY VERSAFIT Double Mobility System 510(k): K083116 Product Code: MEH Device Description The POLARCUP0 Dual Mobility System…
Medacta International S.A.20092

Also cleared against K070278: 7 other devices →

What descends from it? (14)

See all 14

7 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K171934Birmingham Hip (BH) Dual Mobility InsertSmith & Nephew, Inc.20179
K191002OR3O Dual Mobility SystemSmith & Nephew, Inc.20195
K122244Polarcup Dual Mobility SystemSmith & Nephew, Inc.20125
K220959OR3O Dual Mobility SystemSmith & Nephew, Inc.20223
K211176Smith & Nephew Hip SystemsSmith & Nephew, Inc.20223
K181366REDAPT Porous Acetabular ShellSmith & Nephew, Inc.20181
K181491Delta Dual Mobility SystemLima Corporate S.P.A.20190

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 12 years and passes through 4 companies; a new generation was cleared every 2.5 years on median.
  • 2 of the 4 ancestors have a recall of any class.
  • Of its descendants, K171934 (Smith & Nephew, Inc., 2017) has gone furthest, with 9 descendants of its own.
  • 7 other devices also cite its predicate K070278.

How does its category compare?

All LPH devices

LPH Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · LPH

12in 2025

2007: 102008: 102009: 32010: 152011: 162012: 252013: 112014: 202015: 182016: 102017: 122018: 92019: 222020: 72021: 82022: 142023: 102024: 62025: 122026 (partial year): 8
2007high 25 (2012) · low 3 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LPH

153in 2025

2007: 116 days median2008: 86 days median2009: 112 days median2010: 100 days median2011: 110 days median2012: 76 days median2013: 135 days median2014: 129 days median2015: 111 days median2016: 150 days median2017: 121 days median2018: 145 days median2019: 164 days median2020: 164 days median2021: 410 days median2022: 247 days median2023: 111 days median2024: 92 days median2025: 153 days median2026 (partial year): 256 days median
2007high 410 (2021) · low 76 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LPH

4in 2025

2007: 162008: 12009: 22010: 222011: 262012: 302013: 92014: 32015: 12016: 82017: 142018: 22019: 82020: 62021: 42022: 22023: 22024: 12025: 42026 (partial year): 2
2007high 30 (2012) · low 1 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LPH

6,163in 2025

2007: 5092008: 7062009: 1,1562010: 2,0072011: 3,3202012: 3,7852013: 5,0022014: 5,1632015: 5,8302016: 4,9002017: 5,3122018: 5,9542019: 7,1302020: 5,4292021: 5,9782022: 5,2232023: 5,3452024: 5,6262025: 6,163
2007high 7,130 (2019) · low 509 (2007)2025

MAUDE reports naming product code LPH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071011616509
200810861706
2009311221,156
201015100222,007
201116110263,320
20122576303,785
20131113595,002
20142012935,163
20151811115,830
20161015084,900
201712121145,312
2018914525,954
20192216487,130
2020716465,429
2021841045,978
20221424725,223
20231011125,345
202469215,626
20251215346,163
202682562—

What is it indicated for?

The POLARCUP0 Dual Mobility System is indicated for:

* Advanced degeneration of the hip joint as a result of degenerative, post-traumatic or rheumatoid arthritis.

* Fracture or avascular necrosis of the femoral head

* Failure of previous hip surgery: joint reconstruction, internal fixation, arthrodesis, hemiarthroplasty, surface replacement arthroplasty, or total hip replacement

* All forms of osteoarthritis

* Patients with hips at risk of dislocation

* Femoral neck fracture or proximal fracture to hip joint

The POLARCUP0 Dual Mobility System is intended for single use only and depending on its version is to be implanted either with or without bone cement.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K110135: Polarcup Dual Mobility System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K110135

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026