510(k) Report

510(k) · Cleared

Cleared

Sysloc Mini V3

K110157510(k) SpecialCleared Feb 11, 201123-day reviewClass II21 CFR 876.5540

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

JMS North America Corporation · FIE Needle, Fistula

Cleared on Feb 11, 2011 as substantially equivalent to K070234 (Jms North America Corp., 2007) after a 23-day review. Its family tree reaches back 3 generations to 2003. 2 later devices descend from it.

Decided
Feb 11, 2011
Review
23 days
Class
Class II
Product code
FIE
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K030479 (2003). 2 later devices descend from it, 1 citing it directly.

  1. Root · 3 generations backK030479 JMS Sysloc a.V. Fistula Needle Set, JMS Sysloc Apheresis Needle SetJms North America Corp. · 2003
  2. 2 generations backK051814 JMS Sysloc Mini a.V. Fistula Needle Set and Apheresis Needle SetJms North America Corp. · 2005
  3. 1 generation backK070234 JMS Sysloc Mini Avf and Apheresis Needle SetsJms North America Corp. · 2007
  4. This deviceK110157 Sysloc Mini V3JMS North America Corporation · 2011
  5. Descendant · cites it directly · 1 of its ownK142564 JMS SysLoc MINI A.V. Fistula Needle Set (V4), JMS SysLoc MINI…JMS North America Corporation · 2014
  6. Descendant · 2 generations on · 0 of its ownK253469 Ritus™ Safety Fistula Cannula with Anti-Reflux Valve 15G x 30mm…Mozarc Medical Us, LLC · 2026

Most influential descendants

Showing 2 of 2 · See all
  • K142564JMS SysLoc MINI A.V. Fistula Needle Set (V4), JMS SysLoc MINI Apheresis Needle Set (V4)JMS North America Corporation · 2014 · cites it directly1descendant
  • K253469Ritus™ Safety Fistula Cannula with Anti-Reflux Valve 15G x 30mm (1530VSMM); Ritus™…Mozarc Medical Us, LLC · 2026 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K030479JMS Sysloc a.V. Fistula Needle Set, JMS Sysloc Apheresis Needle SetJms North America Corp.2003—
−2K051814JMS Sysloc Mini a.V. Fistula Needle Set and Apheresis Needle SetJms North America Corp.2005—
−1K070234JMS Sysloc Mini Avf and Apheresis Needle SetsJms North America Corp.2007—
0 (this device)K110157Sysloc Mini V3JMS North America Corporation2011—
+1K142564JMS SysLoc MINI A.V. Fistula Needle Set (V4), JMS SysLoc MINI Apheresis Needle…JMS North America Corporation2014—
+2K253469Ritus™ Safety Fistula Cannula with Anti-Reflux Valve 15G x 30mm (1530VSMM)…Mozarc Medical Us, LLC2026—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201410
202610
FIG. 1 — Lineage of K110157, 2003–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FIE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FIE device

  1. #1 K253469 Ritus™ Safety Fistula Cannula with Anti-Reflux…score 13.0 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K070234JMS Sysloc Mini Avf and Apheresis Needle Sets
Summary page 1
…e Name The predicate device used in this submission is JMS SysLoc@ MINI A.V. Fistula Needle Set &JMS SysLoc@® MINI Apheresis Needle Set (V2) [K070234, dated May 22, 2007]. JMS North America Corporation…
Jms North America Corp.2007—

Also cleared against K070234: 1 other device →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K142564JMS SysLoc MINI A.V. Fistula Needle Set (V4), JMS SysLoc MINI Apheresis Needle Set (V4)JMS North America Corporation20141

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 8 years and passes through 2 companies; a new generation was cleared every 2.0 years on median.
  • None of the 3 ancestors has a recall.
  • Of its descendants, K142564 (JMS North America Corporation, 2014) has gone furthest, with 1 descendant of its own.
  • 1 other device also cites its predicate K070234.

How does its category compare?

All FIE devices

FIE Needle, Fistula: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · FIE

1in 2025

2007: 32009: 12010: 32011: 32012: 12014: 22015: 22017: 12018: 12022: 12025: 12026 (partial year): 1
2007high 3 (2007) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FIE

91in 2011

2007: 90 days median2010: 29 days median2011: 91 days median
2007high 91 (2011) · low 29 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FIE

3in 2012

2012: 3
2007high 3 (2012) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FIE

33in 2025

2007: 132008: 102009: 272010: 172011: 22012: 72013: 62014: 42015: 232016: 212017: 142018: 162019: 212020: 32021: 12022: 12023: 582024: 142025: 33
2007high 58 (2023) · low 1 (2021)2025

MAUDE reports naming product code FIE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007390013
20080—010
20091—027
2010329017
201139102
20121—37
20130—06
20142—04
20152—023
20160—021
20171—014
20181—016
20190—021
20200—03
20210—01
20221—01
20230—058
20240—014
20251—033
20261—0—

What is it indicated for?

Use for temporary cannulation (noni-imnplantable, less than 30 days) to vascular access for extracorporeal blood treatment. The device is intended for single use only and has an anti-stick feature integrated as part of the Needle Set which aids in prevention of needle-stick injuries.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K110157: Sysloc Mini V3.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K110157

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026