510(k) Report

510(k) · Cleared

Recalled · Class II · 2021

Optichamber Diamond Valved Holding Chamber

K110293510(k) TraditionalCleared Aug 9, 2011189-day reviewClass II21 CFR 868.5630Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Respironics New Jersey, Inc. · NVP Holding Chambers, Direct Patient Interface

Cleared on Aug 9, 2011 as substantially equivalent to K052332 (Trudell Medical Intl., 2005) after a 189-day review. Its family tree reaches back 1 generation to 2005. It has been recalled once.

Decided
Aug 9, 2011
Review
189 days
Class
Class II
Product code
NVP
Recalls
1
Predicates
1

Its longest line of descent runs back 1 generation to K052332 (2005). No later device cites it as a predicate yet.

K052332 · Aerochamber Z-Stat Plus Valved Holding Chamber · Trudell Medical Intl. · 20052006200820102012
  1. Root · 1 generation backK052332 Aerochamber Z-Stat Plus Valved Holding ChamberTrudell Medical Intl. · 2005
  2. This deviceK110293 Optichamber Diamond Valved Holding ChamberRespironics New Jersey, Inc. · 2011
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K052332Aerochamber Z-Stat Plus Valved Holding ChamberTrudell Medical Intl.2005—
0 (this device)K110293Optichamber Diamond Valved Holding ChamberRespironics New Jersey, Inc.2011—
FIG. 1 — Lineage of K110293, 2005–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NVP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NVP device

  1. #1 K242667 AeroChamber2go Anti-Static Valved Holding…score 9.0 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K052332Aerochamber Z-Stat Plus Valved Holding Chamber
Summary page 2
…rmation: Identification of legally marketed device which we claim substantial equivalence to: AeroChamber Plus Z-Stat Valved Holding Chamber K052332 Trudell Medical International. 725 Third Street London, Ontario Canada, N5V 5G4 4. Device Descri…
Trudell Medical Intl.2005—

Also cleared against K052332: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Mar 16, 2021Class IIZ-1941-2021Environmental controlDue to shipping delays the devices were exposed to temperature excursions of 31.9¿F, intermittently over a 2 hour and 15 minute period of time which may cause inaccurate results.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 2 other devices also cite its predicate K052332.

How does its category compare?

All NVP devices

NVP Holding Chambers, Direct Patient Interface: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · NVP

1in 2025

2007: 12008: 12011: 42012: 12013: 22014: 12016: 12017: 12019: 12022: 12025: 1
2007high 4 (2011) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NVP

235in 2011

2011: 235 days median
2007high 235 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NVP

No recall names NVP since 2007.

Adverse event reports per year · NVP

3in 2024

2017: 22018: 32021: 12022: 22023: 22024: 3
2007high 3 (2018) · low 0 (2007)2025

MAUDE reports naming product code NVP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20081—00
20090—00
20100—00
2011423500
20121—00
20132—00
20141—00
20150—00
20161—00
20171—02
20180—03
20191—00
20200—00
20210—01
20221—02
20230—02
20240—03
20251—00
20260—0—

What is it indicated for?

The OptiChamber Diamond Valved Holding Chamber device is intended to be used by patients who are under the care or treatment of a physician or licensed healthcare professional. The device is intended to be used by these patients to administer aerosolized medication from most pressurized Metered Dose inhalers. The intended environments for use include the home, hospitals and clinics.

For Single Patient Use

Recommended Patient Population:

OptiChamber Diamond: Age 5 and up

OptiChamber Diamond with Small LiteTouch mask: 0 to 18 months

OptiChamber Diamond with Medium LiteTouch mask: 1 to 5 years

OptiChamber Diamond with Large LiteTouch mask: 5 years +

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K110293: Optichamber Diamond Valved Holding Chamber.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K110293

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026